打开STEP7项目时出现报警257:5
server "p7vrislx.dll" for U7T_USD_S32S_ETER_CT objects cound not be found.
打开帮助:
Description of Error:
A file required by STEP 7 was not found. The project may contain objects that can only be processed with a software package that is not installed.
To Correct or Avoid Error:
Please install the required software packages.
or
Make a copy of your project in the SIMATIC Manager [with File> Save As and the "With reorganization (slow)" option]. While the copy is being made,
objects are deleted in the destination project if they belong to uninstalled software packages. The error message is then no longer displayed when
you work with the copy of the project.
项目另存后再打开后报警不出现。
产品版区:SIMATIC S7-300(F)/S7-400(F/H/FH)
悬赏分:5 | 解决时间:2007-12-27 09:54:41 | 提问者: 芮先明 - 高级工程师  第11级
最佳答案
回答者:
xiaoxiaoyu
-
中级技术员  第6级
2007-12-18 09:20:06
提问者对于答案的评价:
还是没搞定
网页上关于257:5的原因也不是很全
可能由于我安装stater v4.0的原因
有时间我重装试试
还是要感谢