Device Diagnostics - [D445] -------------------------------------------------------------------------------- - General - -------------------------------------------------------------------------------- Designation........:: D445 System ID......:: DVD445.4.1 -----------------------------------: Operating state....:: STOP -----------------------------------: Active MAC address:( 1 - 2 ): 00-1F-F8-03-5F-F1: 00-1F-F8-03-5F-F2 : -----------------------------------: IP address:( 1 - 2 ): 172.25.19.12: 192.168.1.201 Subnet dialog box:( 1 - 2 ): 255.255.0.0: 255.255.255.0 Standard gateway:( 1 - 2 ): 0.0.0.0: 0.0.0.0 Order no./designation: 6AU1 445-0AA00-0AA1 Component: CPU: Serial no.: ST-B32028104 Version: A Order no./designation: d4xxkernel Component: OS: Build no.: 47.76.10.0 umc47.76.10d435kernel.1.build Version: 4.1.4.1 Order no./designation: tpcam_ext Component: TP: Build no.: 47.76.10.0 umc47.76.10_x86tpcamext.1.bui Version: 4.1.4.1 Order no./designation: 6AU1400-2PA01-0AA0, Component: Serial no.: 01673287 Version: Order no./designation: Component: OS: Build no.: 0.0.0.0 Version: 0.0.0.0 Order no./designation: SINAMICS integrated Component: OS: Build no.: 0.0.0.0 Version: 2.60.42.0 Order no./designation: Boot loader Component: Serial no.: D4xx_BOOT_V02.10 Version: Order no./designation: Bios Component: Serial no.: V02.02.00.00 Version: -------------------------------------------------------------------------------- -------------------------------------------------------------------------------- -------------------------------------------------------------------------------- - Diagnostics buffer - -------------------------------------------------------------------------------- Event details: 1 of 507 : 21:59:48:564 03.01.92 Event ID: 16# F260:B410 Additional information 4 / 5: 16# C0 50 Additional information 1 / 2 / 3: 16# 000F 0000 0003 PROFIBUS-DP 3: Station recovery, station 15 Outgoing event ................................................................................ Event details: 2 of 507 : 21:59:48:554 03.01.92 Event ID: 16# F260:B410 Additional information 4 / 5: 16# C0 50 Additional information 1 / 2 / 3: 16# 0003 0000 0003 PROFIBUS-DP 3: Station recovery, station 3 Outgoing event ................................................................................ Event details: 3 of 507 : 21:59:11:936 03.01.92 Event ID: 16# F360:B281 Additional information 4 / 5: 16# 00 00 Additional information 1 / 2 / 3: 16# 0003 0000 BC03 Operating mode STOP reached Incoming event ................................................................................ Event details: 4 of 507 : 21:59:11:924 03.01.92 Event ID: 16# F360:B299 Additional information 4 / 5: 16# 00 00 Additional information 1 / 2 / 3: 16# 1203 0000 0000 Operating mode transition from SHUTDOWN to STOP: Start Incoming event ................................................................................ Event details: 5 of 507 : 21:59:10:860 03.01.92 Event ID: 16# F360:B285 Additional information 4 / 5: 16# 00 00 Additional information 1 / 2 / 3: 16# 0012 0000 BC18 Operating mode SHUTDOWN reached Incoming event ................................................................................ Event details: 6 of 507 : 21:59:10:858 03.01.92 Event ID: 16# F360:B295 Additional information 4 / 5: 16# 00 00 Additional information 1 / 2 / 3: 16# 0812 0000 0000 Operating mode transition from RUN to SHUTDOWN: Start Incoming event ................................................................................ Event details: 7 of 507 : 21:59:10:858 03.01.92 Event ID: 16# F360:BE03 Additional information 4 / 5: 16# C4 50 Additional information 1 / 2 / 3: 16# 0006 0000 000A STOP caused by execution system, cause: STOP by user program in the task MotionTask_13 Incoming event ................................................................................ Event details: 8 of 507 : 21:59:10:858 03.01.92 Event ID: 16# F360:B284 Additional information 4 / 5: 16# 00 00 Additional information 1 / 2 / 3: 16# 0008 0000 BC08 Operating mode RUN reached Incoming event ................................................................................ Event details: 9 of 507 : 21:59:10:816 03.01.92 Event ID: 16# F360:B290 Additional information 4 / 5: 16# 00 00 Additional information 1 / 2 / 3: 16# 1108 0000 0000 Operating mode transition from STARTUP to RUN: Start Incoming event ................................................................................ Event details: 10 of 507 : 21:59:10:814 03.01.92 Event ID: 16# F360:B283 Additional information 4 / 5: 16# 00 00 Additional information 1 / 2 / 3: 16# 0011 0000 BC17 Operating mode STARTUP reached Incoming event ................................................................................ Event details: 11 of 507 : 21:59:10:792 03.01.92 Event ID: 16# F360:B28E Additional information 4 / 5: 16# 00 00 Additional information 1 / 2 / 3: 16# 1011 0000 0000 Operating mode transition from STOP_U to STARTUP: Start Incoming event ................................................................................ Event details: 12 of 507 : 21:59:10:792 03.01.92 Event ID: 16# F360:B282 Additional information 4 / 5: 16# 00 00 Additional information 1 / 2 / 3: 16# 0010 0000 BC16 Operating mode STOP_U reached Incoming event ................................................................................ Event details: 13 of 507 : 21:59:10:758 03.01.92 Event ID: 16# F360:B28C Additional information 4 / 5: 16# 00 00 Additional information 1 / 2 / 3: 16# 0310 0000 0000 Operating mode transition from STOP to STOP_U: Start Incoming event ................................................................................ Event details: 14 of 507 : 21:59:10:746 03.01.92 Event ID: 16# F360:B281 Additional information 4 / 5: 16# 00 00 Additional information 1 / 2 / 3: 16# 0003 0000 BC03 Operating mode STOP reached Incoming event ................................................................................ Event details: 15 of 507 : 21:59:06:778 03.01.92 Event ID: 16# F360:B68B Additional information 4 / 5: 16# 00 50 Additional information 1 / 2 / 3: 16# 0003 0000 0001 Loading user program, mode: 3 Incoming event ................................................................................ Event details: 16 of 507 : 21:58:39:764 03.01.92 Event ID: 16# F260:B410 Additional information 4 / 5: 16# C0 50 Additional information 1 / 2 / 3: 16# 0028 0000 0001 PROFIBUS-DP 1: Station recovery, station 40 Outgoing event ................................................................................ Event details: 17 of 507 : 21:58:39:744 03.01.92 Event ID: 16# F260:B40E Additional information 4 / 5: 16# C0 50 Additional information 1 / 2 / 3: 16# 0028 0000 0001 PROFIBUS-DP 1: Module ok, station: 40, slot: 0 Outgoing event ................................................................................ Event details: 18 of 507 : 21:58:39:034 03.01.92 Event ID: 16# F260:B410 Additional information 4 / 5: 16# C0 50 Additional information 1 / 2 / 3: 16# 0035 0000 0002 PROFIBUS-DP 2: Station recovery, station 53 Outgoing event ................................................................................ Event details: 19 of 507 : 21:58:39:014 03.01.92 Event ID: 16# F260:B40E Additional information 4 / 5: 16# C0 50 Additional information 1 / 2 / 3: 16# 0035 0000 0002 PROFIBUS-DP 2: Module ok, station: 53, slot: 0 Outgoing event ................................................................................ Event details: 20 of 507 : 21:58:39:004 03.01.92 Event ID: 16# F360:B28B Additional information 4 / 5: 16# 00 00 Additional information 1 / 2 / 3: 16# 0103 0000 0000 Operating mode transition from INIT to STOP: Start Incoming event ................................................................................ Event details: 21 of 507 : 21:58:39:004 03.01.92 Event ID: 16# F360:B280 Additional information 4 / 5: 16# 00 00 Additional information 1 / 2 / 3: 16# 0001 0000 BC01 Operating mode INIT reached Incoming event ................................................................................ Event details: 22 of 507 : 21:57:54:000 03.01.92 Event ID: 16# F360:B486 Additional information 4 / 5: 16# 00 00 Additional information 1 / 2 / 3: 16# FFFF 0000 0000 SINAMICS and PROFIBUS software loaded and started Incoming event ................................................................................ Event details: 23 of 507 : 21:57:54:000 03.01.92 Event ID: 16# F260:B815 Additional information 4 / 5: 16# 00 00 Additional information 1 / 2 / 3: 16# 0000 0000 0000 Device with battery module Outgoing event ................................................................................ Event details: 24 of 507 : 01:04:50:924 01.01.92 Event ID: 16# F360:B40F Additional information 4 / 5: 16# C0 50 Additional information 1 / 2 / 3: 16# 0028 0000 0001 PROFIBUS-DP 1: Station failure, station 40 Incoming event ................................................................................ Event details: 25 of 507 : 01:04:50:914 01.01.92 Event ID: 16# F360:BF80 Additional information 4 / 5: 16# 00 53 Additional information 1 / 2 / 3: 16# 4E25 0000 3C03 Technological alarm A_HA: Alarm Error 20005 : Device type:2, log. address:1144 faulted. (Bit:0, encoder number:0, reason: 0x200h) Incoming event ................................................................................ Event details: 26 of 507 : 01:04:50:914 01.01.92 Event ID: 16# F360:BF80 Additional information 4 / 5: 16# 00 53 Additional information 1 / 2 / 3: 16# 4E25 0000 3C02 Technological alarm A_SL_X: Alarm Error 20005 : Device type:2, log. address:284 faulted. (Bit:0, encoder number:0, reason: 0x200h) Incoming event ................................................................................ Event details: 27 of 507 : 01:04:50:910 01.01.92 Event ID: 16# F360:BF80 Additional information 4 / 5: 16# 00 53 Additional information 1 / 2 / 3: 16# 4E25 0000 3C01 Technological alarm A_FZ3: Alarm Error 20005 : Device type:2, log. address:310 faulted. (Bit:0, encoder number:0, reason: 0x200h) Incoming event ................................................................................ Event details: 28 of 507 : 01:04:50:910 01.01.92 Event ID: 16# F360:BF80 Additional information 4 / 5: 16# 00 53 Additional information 1 / 2 / 3: 16# 4E25 0000 3C00 Technological alarm A_WA1: Alarm Error 20005 : Device type:2, log. address:338 faulted. (Bit:0, encoder number:0, reason: 0x200h) Incoming event ................................................................................ Event details: 29 of 507 : 01:04:50:910 01.01.92 Event ID: 16# F360:BF80 Additional information 4 / 5: 16# 00 53 Additional information 1 / 2 / 3: 16# 4E25 0000 3BFF Technological alarm A_SL_YR: Alarm Error 20005 : Device type:2, log. address:386 faulted. (Bit:0, encoder number:0, reason: 0x200h) Incoming event ................................................................................ Event details: 30 of 507 : 01:04:50:910 01.01.92 Event ID: 16# F360:BF80 Additional information 4 / 5: 16# 00 53 Additional information 1 / 2 / 3: 16# 4E25 0000 3BFE Technological alarm A_SL_YL: Alarm Error 20005 : Device type:2, log. address:406 faulted. (Bit:0, encoder number:0, reason: 0x200h) Incoming event ................................................................................ Event details: 31 of 507 : 01:04:50:910 01.01.92 Event ID: 16# F360:BF80 Additional information 4 / 5: 16# 00 53 Additional information 1 / 2 / 3: 16# 4E25 0000 3BFD Technological alarm A_FZ2: Alarm Error 20005 : Device type:2, log. address:264 faulted. (Bit:0, encoder number:0, reason: 0x200h) Incoming event ................................................................................ Event details: 32 of 507 : 01:04:50:910 01.01.92 Event ID: 16# F360:BF80 Additional information 4 / 5: 16# 00 53 Additional information 1 / 2 / 3: 16# 4E25 0000 3BFC Technological alarm A_STK_R: Alarm Error 20005 : Device type:2, log. address:966 faulted. (Bit:0, encoder number:0, reason: 0x200h) Incoming event ................................................................................ Event details: 33 of 507 : 01:04:50:910 01.01.92 Event ID: 16# F360:BF80 Additional information 4 / 5: 16# 00 53 Additional information 1 / 2 / 3: 16# 4E25 0000 3BFB Technological alarm A_WA2: Alarm Error 20005 : Device type:2, log. address:366 faulted. (Bit:0, encoder number:0, reason: 0x200h) Incoming event ................................................................................ Event details: 34 of 507 : 01:04:50:910 01.01.92 Event ID: 16# F360:BF80 Additional information 4 / 5: 16# 00 53 Additional information 1 / 2 / 3: 16# 4E25 0000 3BFA Technological alarm A_STK_L: Alarm Error 20005 : Device type:2, log. address:992 faulted. (Bit:0, encoder number:0, reason: 0x200h) Incoming event ................................................................................ Event details: 35 of 507 : 01:00:36:960 01.01.92 Event ID: 16# F360:B281 Additional information 4 / 5: 16# 00 00 Additional information 1 / 2 / 3: 16# 0003 0000 BC03 Operating mode STOP reached Incoming event ................................................................................ Event details: 36 of 507 : 01:00:36:948 01.01.92 Event ID: 16# F360:B299 Additional information 4 / 5: 16# 00 00 Additional information 1 / 2 / 3: 16# 1203 0000 0000 Operating mode transition from SHUTDOWN to STOP: Start Incoming event ................................................................................ Event details: 37 of 507 : 01:00:35:884 01.01.92 Event ID: 16# F360:B285 Additional information 4 / 5: 16# 00 00 Additional information 1 / 2 / 3: 16# 0012 0000 BC18 Operating mode SHUTDOWN reached Incoming event ................................................................................ Event details: 38 of 507 : 01:00:35:882 01.01.92 Event ID: 16# F360:B295 Additional information 4 / 5: 16# 00 00 Additional information 1 / 2 / 3: 16# 0812 0000 0000 Operating mode transition from RUN to SHUTDOWN: Start Incoming event ................................................................................ Event details: 39 of 507 : 01:00:35:882 01.01.92 Event ID: 16# F360:BE03 Additional information 4 / 5: 16# C4 50 Additional information 1 / 2 / 3: 16# 0006 0000 000A STOP caused by execution system, cause: STOP by user program in the task MotionTask_13 Incoming event ................................................................................ Event details: 40 of 507 : 01:00:35:882 01.01.92 Event ID: 16# F360:B284 Additional information 4 / 5: 16# 00 00 Additional information 1 / 2 / 3: 16# 0008 0000 BC08 Operating mode RUN reached Incoming event ................................................................................ Event details: 41 of 507 : 01:00:35:840 01.01.92 Event ID: 16# F360:B290 Additional information 4 / 5: 16# 00 00 Additional information 1 / 2 / 3: 16# 1108 0000 0000 Operating mode transition from STARTUP to RUN: Start Incoming event ................................................................................ Event details: 42 of 507 : 01:00:35:838 01.01.92 Event ID: 16# F360:B283 Additional information 4 / 5: 16# 00 00 Additional information 1 / 2 / 3: 16# 0011 0000 BC17 Operating mode STARTUP reached Incoming event ................................................................................ Event details: 43 of 507 : 01:00:35:816 01.01.92 Event ID: 16# F360:B28E Additional information 4 / 5: 16# 00 00 Additional information 1 / 2 / 3: 16# 1011 0000 0000 Operating mode transition from STOP_U to STARTUP: Start Incoming event ................................................................................ Event details: 44 of 507 : 01:00:35:816 01.01.92 Event ID: 16# F360:B282 Additional information 4 / 5: 16# 00 00 Additional information 1 / 2 / 3: 16# 0010 0000 BC16 Operating mode STOP_U reached Incoming event ................................................................................ Event details: 45 of 507 : 01:00:35:784 01.01.92 Event ID: 16# F360:B28C Additional information 4 / 5: 16# 00 00 Additional information 1 / 2 / 3: 16# 0310 0000 0000 Operating mode transition from STOP to STOP_U: Start Incoming event ................................................................................ Event details: 46 of 507 : 00:47:55:780 01.01.92 Event ID: 16# F360:B281 Additional information 4 / 5: 16# 00 00 Additional information 1 / 2 / 3: 16# 0003 0000 BC03 Operating mode STOP reached Incoming event ................................................................................ Event details: 47 of 507 : 00:47:55:768 01.01.92 Event ID: 16# F360:B299 Additional information 4 / 5: 16# 00 00 Additional information 1 / 2 / 3: 16# 1203 0000 0000 Operating mode transition from SHUTDOWN to STOP: Start Incoming event ................................................................................ Event details: 48 of 507 : 00:47:54:698 01.01.92 Event ID: 16# F360:B285 Additional information 4 / 5: 16# 00 00 Additional information 1 / 2 / 3: 16# 0012 0000 BC18 Operating mode SHUTDOWN reached Incoming event ................................................................................ Event details: 49 of 507 : 00:47:54:692 01.01.92 Event ID: 16# F360:B295 Additional information 4 / 5: 16# 00 00 Additional information 1 / 2 / 3: 16# 0812 0000 0000 Operating mode transition from RUN to SHUTDOWN: Start Incoming event ................................................................................ Event details: 50 of 507 : 00:47:54:692 01.01.92 Event ID: 16# F360:BE03 Additional information 4 / 5: 16# C4 50 Additional information 1 / 2 / 3: 16# 0006 0000 000A STOP caused by execution system, cause: STOP by user program in the task MotionTask_13 Incoming event ................................................................................ Event details: 51 of 507 : 00:47:54:688 01.01.92 Event ID: 16# F360:B284 Additional information 4 / 5: 16# 00 00 Additional information 1 / 2 / 3: 16# 0008 0000 BC08 Operating mode RUN reached Incoming event ................................................................................ Event details: 52 of 507 : 00:47:54:646 01.01.92 Event ID: 16# F360:B290 Additional information 4 / 5: 16# 00 00 Additional information 1 / 2 / 3: 16# 1108 0000 0000 Operating mode transition from STARTUP to RUN: Start Incoming event ................................................................................ Event details: 53 of 507 : 00:47:54:642 01.01.92 Event ID: 16# F360:B283 Additional information 4 / 5: 16# 00 00 Additional information 1 / 2 / 3: 16# 0011 0000 BC17 Operating mode STARTUP reached Incoming event ................................................................................ Event details: 54 of 507 : 00:47:54:602 01.01.92 Event ID: 16# F360:B28E Additional information 4 / 5: 16# 00 00 Additional information 1 / 2 / 3: 16# 1011 0000 0000 Operating mode transition from STOP_U to STARTUP: Start Incoming event ................................................................................ Event details: 55 of 507 : 00:47:54:602 01.01.92 Event ID: 16# F360:B282 Additional information 4 / 5: 16# 00 00 Additional information 1 / 2 / 3: 16# 0010 0000 BC16 Operating mode STOP_U reached Incoming event ................................................................................ Event details: 56 of 507 : 00:47:54:566 01.01.92 Event ID: 16# F360:B28C Additional information 4 / 5: 16# 00 00 Additional information 1 / 2 / 3: 16# 0310 0000 0000 Operating mode transition from STOP to STOP_U: Start Incoming event ................................................................................ Event details: 57 of 507 : 00:46:27:244 01.01.92 Event ID: 16# F260:B410 Additional information 4 / 5: 16# C0 50 Additional information 1 / 2 / 3: 16# 000F 0000 0003 PROFIBUS-DP 3: Station recovery, station 15 Outgoing event ................................................................................ Event details: 58 of 507 : 00:46:27:234 01.01.92 Event ID: 16# F260:B410 Additional information 4 / 5: 16# C0 50 Additional information 1 / 2 / 3: 16# 0003 0000 0003 PROFIBUS-DP 3: Station recovery, station 3 Outgoing event ................................................................................ Event details: 59 of 507 : 00:45:50:036 01.01.92 Event ID: 16# F360:B281 Additional information 4 / 5: 16# 00 00 Additional information 1 / 2 / 3: 16# 0003 0000 BC03 Operating mode STOP reached Incoming event ................................................................................ Event details: 60 of 507 : 00:45:50:024 01.01.92 Event ID: 16# F360:B299 Additional information 4 / 5: 16# 00 00 Additional information 1 / 2 / 3: 16# 1203 0000 0000 Operating mode transition from SHUTDOWN to STOP: Start Incoming event ................................................................................ Event details: 61 of 507 : 00:45:48:960 01.01.92 Event ID: 16# F360:B285 Additional information 4 / 5: 16# 00 00 Additional information 1 / 2 / 3: 16# 0012 0000 BC18 Operating mode SHUTDOWN reached Incoming event ................................................................................ Event details: 62 of 507 : 00:45:48:958 01.01.92 Event ID: 16# F360:B295 Additional information 4 / 5: 16# 00 00 Additional information 1 / 2 / 3: 16# 0812 0000 0000 Operating mode transition from RUN to SHUTDOWN: Start Incoming event ................................................................................ Event details: 63 of 507 : 00:45:48:958 01.01.92 Event ID: 16# F360:BE03 Additional information 4 / 5: 16# C4 50 Additional information 1 / 2 / 3: 16# 0006 0000 000A STOP caused by execution system, cause: STOP by user program in the task MotionTask_13 Incoming event ................................................................................ Event details: 64 of 507 : 00:45:48:958 01.01.92 Event ID: 16# F360:B284 Additional information 4 / 5: 16# 00 00 Additional information 1 / 2 / 3: 16# 0008 0000 BC08 Operating mode RUN reached Incoming event ................................................................................ Event details: 65 of 507 : 00:45:48:916 01.01.92 Event ID: 16# F360:B290 Additional information 4 / 5: 16# 00 00 Additional information 1 / 2 / 3: 16# 1108 0000 0000 Operating mode transition from STARTUP to RUN: Start Incoming event ................................................................................ Event details: 66 of 507 : 00:45:48:914 01.01.92 Event ID: 16# F360:B283 Additional information 4 / 5: 16# 00 00 Additional information 1 / 2 / 3: 16# 0011 0000 BC17 Operating mode STARTUP reached Incoming event ................................................................................ Event details: 67 of 507 : 00:45:48:892 01.01.92 Event ID: 16# F360:B28E Additional information 4 / 5: 16# 00 00 Additional information 1 / 2 / 3: 16# 1011 0000 0000 Operating mode transition from STOP_U to STARTUP: Start Incoming event ................................................................................ Event details: 68 of 507 : 00:45:48:892 01.01.92 Event ID: 16# F360:B282 Additional information 4 / 5: 16# 00 00 Additional information 1 / 2 / 3: 16# 0010 0000 BC16 Operating mode STOP_U reached Incoming event ................................................................................ Event details: 69 of 507 : 00:45:48:858 01.01.92 Event ID: 16# F360:B28C Additional information 4 / 5: 16# 00 00 Additional information 1 / 2 / 3: 16# 0310 0000 0000 Operating mode transition from STOP to STOP_U: Start Incoming event ................................................................................ Event details: 70 of 507 : 00:45:48:846 01.01.92 Event ID: 16# F360:B281 Additional information 4 / 5: 16# 00 00 Additional information 1 / 2 / 3: 16# 0003 0000 BC03 Operating mode STOP reached Incoming event ................................................................................ Event details: 71 of 507 : 00:45:44:850 01.01.92 Event ID: 16# F360:B68B Additional information 4 / 5: 16# 00 50 Additional information 1 / 2 / 3: 16# 0003 0000 0001 Loading user program, mode: 3 Incoming event ................................................................................ Event details: 72 of 507 : 00:45:17:764 01.01.92 Event ID: 16# F260:B410 Additional information 4 / 5: 16# C0 50 Additional information 1 / 2 / 3: 16# 0028 0000 0001 PROFIBUS-DP 1: Station recovery, station 40 Outgoing event ................................................................................ Event details: 73 of 507 : 00:45:17:744 01.01.92 Event ID: 16# F260:B40E Additional information 4 / 5: 16# C0 50 Additional information 1 / 2 / 3: 16# 0028 0000 0001 PROFIBUS-DP 1: Module ok, station: 40, slot: 0 Outgoing event ................................................................................ Event details: 74 of 507 : 00:45:17:034 01.01.92 Event ID: 16# F260:B410 Additional information 4 / 5: 16# C0 50 Additional information 1 / 2 / 3: 16# 0035 0000 0002 PROFIBUS-DP 2: Station recovery, station 53 Outgoing event ................................................................................ Event details: 75 of 507 : 00:45:17:014 01.01.92 Event ID: 16# F260:B40E Additional information 4 / 5: 16# C0 50 Additional information 1 / 2 / 3: 16# 0035 0000 0002 PROFIBUS-DP 2: Module ok, station: 53, slot: 0 Outgoing event ................................................................................ Event details: 76 of 507 : 00:45:17:004 01.01.92 Event ID: 16# F360:B28B Additional information 4 / 5: 16# 00 00 Additional information 1 / 2 / 3: 16# 0103 0000 0000 Operating mode transition from INIT to STOP: Start Incoming event ................................................................................ Event details: 77 of 507 : 00:45:17:004 01.01.92 Event ID: 16# F360:B280 Additional information 4 / 5: 16# 00 00 Additional information 1 / 2 / 3: 16# 0001 0000 BC01 Operating mode INIT reached Incoming event ................................................................................ Event details: 78 of 507 : 00:44:32:000 01.01.92 Event ID: 16# F360:B486 Additional information 4 / 5: 16# 00 00 Additional information 1 / 2 / 3: 16# FFFF 0000 0000 SINAMICS and PROFIBUS software loaded and started Incoming event ................................................................................ Event details: 79 of 507 : 00:44:32:000 01.01.92 Event ID: 16# F260:B815 Additional information 4 / 5: 16# 00 00 Additional information 1 / 2 / 3: 16# 0000 0000 0000 Device with battery module Outgoing event ................................................................................ Event details: 80 of 507 : 00:41:38:804 01.01.92 Event ID: 16# F360:B40F Additional information 4 / 5: 16# C0 50 Additional information 1 / 2 / 3: 16# 0028 0000 0001 PROFIBUS-DP 1: Station failure, station 40 Incoming event ................................................................................ Event details: 81 of 507 : 00:24:24:774 01.01.92 Event ID: 16# F260:B410 Additional information 4 / 5: 16# C0 50 Additional information 1 / 2 / 3: 16# 0003 0000 0003 PROFIBUS-DP 3: Station recovery, station 3 Outgoing event ................................................................................ Event details: 82 of 507 : 00:24:24:644 01.01.92 Event ID: 16# F260:B410 Additional information 4 / 5: 16# C0 50 Additional information 1 / 2 / 3: 16# 000F 0000 0003 PROFIBUS-DP 3: Station recovery, station 15 Outgoing event ................................................................................ Event details: 83 of 507 : 00:23:48:036 01.01.92 Event ID: 16# F360:B281 Additional information 4 / 5: 16# 00 00 Additional information 1 / 2 / 3: 16# 0003 0000 BC03 Operating mode STOP reached Incoming event ................................................................................ Event details: 84 of 507 : 00:23:48:024 01.01.92 Event ID: 16# F360:B299 Additional information 4 / 5: 16# 00 00 Additional information 1 / 2 / 3: 16# 1203 0000 0000 Operating mode transition from SHUTDOWN to STOP: Start Incoming event ................................................................................ Event details: 85 of 507 : 00:23:46:960 01.01.92 Event ID: 16# F360:B285 Additional information 4 / 5: 16# 00 00 Additional information 1 / 2 / 3: 16# 0012 0000 BC18 Operating mode SHUTDOWN reached Incoming event ................................................................................ Event details: 86 of 507 : 00:23:46:958 01.01.92 Event ID: 16# F360:B295 Additional information 4 / 5: 16# 00 00 Additional information 1 / 2 / 3: 16# 0812 0000 0000 Operating mode transition from RUN to SHUTDOWN: Start Incoming event ................................................................................ Event details: 87 of 507 : 00:23:46:958 01.01.92 Event ID: 16# F360:BE03 Additional information 4 / 5: 16# C4 50 Additional information 1 / 2 / 3: 16# 0006 0000 000A STOP caused by execution system, cause: STOP by user program in the task MotionTask_13 Incoming event ................................................................................ Event details: 88 of 507 : 00:23:46:958 01.01.92 Event ID: 16# F360:B284 Additional information 4 / 5: 16# 00 00 Additional information 1 / 2 / 3: 16# 0008 0000 BC08 Operating mode RUN reached Incoming event ................................................................................ Event details: 89 of 507 : 00:23:46:916 01.01.92 Event ID: 16# F360:B290 Additional information 4 / 5: 16# 00 00 Additional information 1 / 2 / 3: 16# 1108 0000 0000 Operating mode transition from STARTUP to RUN: Start Incoming event ................................................................................ Event details: 90 of 507 : 00:23:46:914 01.01.92 Event ID: 16# F360:B283 Additional information 4 / 5: 16# 00 00 Additional information 1 / 2 / 3: 16# 0011 0000 BC17 Operating mode STARTUP reached Incoming event ................................................................................ Event details: 91 of 507 : 00:23:46:892 01.01.92 Event ID: 16# F360:B28E Additional information 4 / 5: 16# 00 00 Additional information 1 / 2 / 3: 16# 1011 0000 0000 Operating mode transition from STOP_U to STARTUP: Start Incoming event ................................................................................ Event details: 92 of 507 : 00:23:46:892 01.01.92 Event ID: 16# F360:B282 Additional information 4 / 5: 16# 00 00 Additional information 1 / 2 / 3: 16# 0010 0000 BC16 Operating mode STOP_U reached Incoming event ................................................................................ Event details: 93 of 507 : 00:23:46:858 01.01.92 Event ID: 16# F360:B28C Additional information 4 / 5: 16# 00 00 Additional information 1 / 2 / 3: 16# 0310 0000 0000 Operating mode transition from STOP to STOP_U: Start Incoming event ................................................................................ Event details: 94 of 507 : 00:23:46:846 01.01.92 Event ID: 16# F360:B281 Additional information 4 / 5: 16# 00 00 Additional information 1 / 2 / 3: 16# 0003 0000 BC03 Operating mode STOP reached Incoming event ................................................................................ Event details: 95 of 507 : 00:23:42:864 01.01.92 Event ID: 16# F360:B68B Additional information 4 / 5: 16# 00 50 Additional information 1 / 2 / 3: 16# 0003 0000 0001 Loading user program, mode: 3 Incoming event ................................................................................ Event details: 96 of 507 : 00:23:15:764 01.01.92 Event ID: 16# F260:B410 Additional information 4 / 5: 16# C0 50 Additional information 1 / 2 / 3: 16# 0028 0000 0001 PROFIBUS-DP 1: Station recovery, station 40 Outgoing event ................................................................................ Event details: 97 of 507 : 00:23:15:744 01.01.92 Event ID: 16# F260:B40E Additional information 4 / 5: 16# C0 50 Additional information 1 / 2 / 3: 16# 0028 0000 0001 PROFIBUS-DP 1: Module ok, station: 40, slot: 0 Outgoing event ................................................................................ Event details: 98 of 507 : 00:23:15:034 01.01.92 Event ID: 16# F260:B410 Additional information 4 / 5: 16# C0 50 Additional information 1 / 2 / 3: 16# 0035 0000 0002 PROFIBUS-DP 2: Station recovery, station 53 Outgoing event ................................................................................ Event details: 99 of 507 : 00:23:15:014 01.01.92 Event ID: 16# F260:B40E Additional information 4 / 5: 16# C0 50 Additional information 1 / 2 / 3: 16# 0035 0000 0002 PROFIBUS-DP 2: Module ok, station: 53, slot: 0 Outgoing event ................................................................................ Event details: 100 of 507 : 00:23:15:004 01.01.92 Event ID: 16# F360:B28B Additional information 4 / 5: 16# 00 00 Additional information 1 / 2 / 3: 16# 0103 0000 0000 Operating mode transition from INIT to STOP: Start Incoming event ................................................................................ Event details: 101 of 507 : 00:23:15:004 01.01.92 Event ID: 16# F360:B280 Additional information 4 / 5: 16# 00 00 Additional information 1 / 2 / 3: 16# 0001 0000 BC01 Operating mode INIT reached Incoming event ................................................................................ Event details: 102 of 507 : 00:22:31:000 01.01.92 Event ID: 16# F360:B486 Additional information 4 / 5: 16# 00 00 Additional information 1 / 2 / 3: 16# FFFF 0000 0000 SINAMICS and PROFIBUS software loaded and started Incoming event ................................................................................ Event details: 103 of 507 : 00:22:31:000 01.01.92 Event ID: 16# F260:B815 Additional information 4 / 5: 16# 00 00 Additional information 1 / 2 / 3: 16# 0000 0000 0000 Device with battery module Outgoing event ................................................................................ Event details: 104 of 507 : 00:22:04:254 01.01.92 Event ID: 16# F360:B40F Additional information 4 / 5: 16# C0 50 Additional information 1 / 2 / 3: 16# 0028 0000 0001 PROFIBUS-DP 1: Station failure, station 40 Incoming event ................................................................................ Event details: 105 of 507 : 00:12:07:984 01.01.92 Event ID: 16# F260:B410 Additional information 4 / 5: 16# C0 50 Additional information 1 / 2 / 3: 16# 000F 0000 0003 PROFIBUS-DP 3: Station recovery, station 15 Outgoing event ................................................................................ Event details: 106 of 507 : 00:12:07:974 01.01.92 Event ID: 16# F260:B410 Additional information 4 / 5: 16# C0 50 Additional information 1 / 2 / 3: 16# 0003 0000 0003 PROFIBUS-DP 3: Station recovery, station 3 Outgoing event ................................................................................ Event details: 107 of 507 : 00:11:31:036 01.01.92 Event ID: 16# F360:B281 Additional information 4 / 5: 16# 00 00 Additional information 1 / 2 / 3: 16# 0003 0000 BC03 Operating mode STOP reached Incoming event ................................................................................ Event details: 108 of 507 : 00:11:31:024 01.01.92 Event ID: 16# F360:B299 Additional information 4 / 5: 16# 00 00 Additional information 1 / 2 / 3: 16# 1203 0000 0000 Operating mode transition from SHUTDOWN to STOP: Start Incoming event ................................................................................ Event details: 109 of 507 : 00:11:29:960 01.01.92 Event ID: 16# F360:B285 Additional information 4 / 5: 16# 00 00 Additional information 1 / 2 / 3: 16# 0012 0000 BC18 Operating mode SHUTDOWN reached Incoming event ................................................................................ Event details: 110 of 507 : 00:11:29:958 01.01.92 Event ID: 16# F360:B295 Additional information 4 / 5: 16# 00 00 Additional information 1 / 2 / 3: 16# 0812 0000 0000 Operating mode transition from RUN to SHUTDOWN: Start Incoming event ................................................................................ Event details: 111 of 507 : 00:11:29:958 01.01.92 Event ID: 16# F360:BE03 Additional information 4 / 5: 16# C4 50 Additional information 1 / 2 / 3: 16# 0006 0000 000A STOP caused by execution system, cause: STOP by user program in the task MotionTask_13 Incoming event ................................................................................ Event details: 112 of 507 : 00:11:29:958 01.01.92 Event ID: 16# F360:B284 Additional information 4 / 5: 16# 00 00 Additional information 1 / 2 / 3: 16# 0008 0000 BC08 Operating mode RUN reached Incoming event ................................................................................ Event details: 113 of 507 : 00:11:29:916 01.01.92 Event ID: 16# F360:B290 Additional information 4 / 5: 16# 00 00 Additional information 1 / 2 / 3: 16# 1108 0000 0000 Operating mode transition from STARTUP to RUN: Start Incoming event ................................................................................ Event details: 114 of 507 : 00:11:29:914 01.01.92 Event ID: 16# F360:B283 Additional information 4 / 5: 16# 00 00 Additional information 1 / 2 / 3: 16# 0011 0000 BC17 Operating mode STARTUP reached Incoming event ................................................................................ Event details: 115 of 507 : 00:11:29:892 01.01.92 Event ID: 16# F360:B28E Additional information 4 / 5: 16# 00 00 Additional information 1 / 2 / 3: 16# 1011 0000 0000 Operating mode transition from STOP_U to STARTUP: Start Incoming event ................................................................................ Event details: 116 of 507 : 00:11:29:892 01.01.92 Event ID: 16# F360:B282 Additional information 4 / 5: 16# 00 00 Additional information 1 / 2 / 3: 16# 0010 0000 BC16 Operating mode STOP_U reached Incoming event ................................................................................ Event details: 117 of 507 : 00:11:29:858 01.01.92 Event ID: 16# F360:B28C Additional information 4 / 5: 16# 00 00 Additional information 1 / 2 / 3: 16# 0310 0000 0000 Operating mode transition from STOP to STOP_U: Start Incoming event ................................................................................ Event details: 118 of 507 : 00:11:29:846 01.01.92 Event ID: 16# F360:B281 Additional information 4 / 5: 16# 00 00 Additional information 1 / 2 / 3: 16# 0003 0000 BC03 Operating mode STOP reached Incoming event ................................................................................ Event details: 119 of 507 : 00:11:25:884 01.01.92 Event ID: 16# F360:B68B Additional information 4 / 5: 16# 00 50 Additional information 1 / 2 / 3: 16# 0003 0000 0001 Loading user program, mode: 3 Incoming event ................................................................................ Event details: 120 of 507 : 00:10:58:764 01.01.92 Event ID: 16# F260:B410 Additional information 4 / 5: 16# C0 50 Additional information 1 / 2 / 3: 16# 0028 0000 0001 PROFIBUS-DP 1: Station recovery, station 40 Outgoing event ................................................................................ Event details: 121 of 507 : 00:10:58:744 01.01.92 Event ID: 16# F260:B40E Additional information 4 / 5: 16# C0 50 Additional information 1 / 2 / 3: 16# 0028 0000 0001 PROFIBUS-DP 1: Module ok, station: 40, slot: 0 Outgoing event ................................................................................ Event details: 122 of 507 : 00:10:58:034 01.01.92 Event ID: 16# F260:B410 Additional information 4 / 5: 16# C0 50 Additional information 1 / 2 / 3: 16# 0035 0000 0002 PROFIBUS-DP 2: Station recovery, station 53 Outgoing event ................................................................................ Event details: 123 of 507 : 00:10:58:014 01.01.92 Event ID: 16# F260:B40E Additional information 4 / 5: 16# C0 50 Additional information 1 / 2 / 3: 16# 0035 0000 0002 PROFIBUS-DP 2: Module ok, station: 53, slot: 0 Outgoing event ................................................................................ Event details: 124 of 507 : 00:10:58:004 01.01.92 Event ID: 16# F360:B28B Additional information 4 / 5: 16# 00 00 Additional information 1 / 2 / 3: 16# 0103 0000 0000 Operating mode transition from INIT to STOP: Start Incoming event ................................................................................ Event details: 125 of 507 : 00:10:58:004 01.01.92 Event ID: 16# F360:B280 Additional information 4 / 5: 16# 00 00 Additional information 1 / 2 / 3: 16# 0001 0000 BC01 Operating mode INIT reached Incoming event ................................................................................ Event details: 126 of 507 : 00:10:14:000 01.01.92 Event ID: 16# F360:B486 Additional information 4 / 5: 16# 00 00 Additional information 1 / 2 / 3: 16# FFFF 0000 0000 SINAMICS and PROFIBUS software loaded and started Incoming event ................................................................................ Event details: 127 of 507 : 00:10:14:000 01.01.92 Event ID: 16# F260:B815 Additional information 4 / 5: 16# 00 00 Additional information 1 / 2 / 3: 16# 0000 0000 0000 Device with battery module Outgoing event ................................................................................ Event details: 128 of 507 : 00:09:47:144 01.01.92 Event ID: 16# F360:B40F Additional information 4 / 5: 16# C0 50 Additional information 1 / 2 / 3: 16# 0028 0000 0001 PROFIBUS-DP 1: Station failure, station 40 Incoming event ................................................................................ Event details: 129 of 507 : 00:03:28:184 01.01.92 Event ID: 16# F260:B410 Additional information 4 / 5: 16# C0 50 Additional information 1 / 2 / 3: 16# 000F 0000 0003 PROFIBUS-DP 3: Station recovery, station 15 Outgoing event ................................................................................ Event details: 130 of 507 : 00:03:28:174 01.01.92 Event ID: 16# F260:B410 Additional information 4 / 5: 16# C0 50 Additional information 1 / 2 / 3: 16# 0003 0000 0003 PROFIBUS-DP 3: Station recovery, station 3 Outgoing event ................................................................................ Event details: 131 of 507 : 00:01:02:136 01.01.92 Event ID: 16# F360:B281 Additional information 4 / 5: 16# 00 00 Additional information 1 / 2 / 3: 16# 0003 0000 BC03 Operating mode STOP reached Incoming event ................................................................................ Event details: 132 of 507 : 00:01:02:124 01.01.92 Event ID: 16# F360:B299 Additional information 4 / 5: 16# 00 00 Additional information 1 / 2 / 3: 16# 1203 0000 0000 Operating mode transition from SHUTDOWN to STOP: Start Incoming event ................................................................................ Event details: 133 of 507 : 00:01:01:060 01.01.92 Event ID: 16# F360:B285 Additional information 4 / 5: 16# 00 00 Additional information 1 / 2 / 3: 16# 0012 0000 BC18 Operating mode SHUTDOWN reached Incoming event ................................................................................ Event details: 134 of 507 : 00:01:01:058 01.01.92 Event ID: 16# F360:B295 Additional information 4 / 5: 16# 00 00 Additional information 1 / 2 / 3: 16# 0812 0000 0000 Operating mode transition from RUN to SHUTDOWN: Start Incoming event ................................................................................ Event details: 135 of 507 : 00:01:01:058 01.01.92 Event ID: 16# F360:BE03 Additional information 4 / 5: 16# C4 50 Additional information 1 / 2 / 3: 16# 0006 0000 000A STOP caused by execution system, cause: STOP by user program in the task MotionTask_13 Incoming event ................................................................................ Event details: 136 of 507 : 00:01:01:058 01.01.92 Event ID: 16# F360:B284 Additional information 4 / 5: 16# 00 00 Additional information 1 / 2 / 3: 16# 0008 0000 BC08 Operating mode RUN reached Incoming event ................................................................................ Event details: 137 of 507 : 00:01:01:016 01.01.92 Event ID: 16# F360:B290 Additional information 4 / 5: 16# 00 00 Additional information 1 / 2 / 3: 16# 1108 0000 0000 Operating mode transition from STARTUP to RUN: Start Incoming event ................................................................................ Event details: 138 of 507 : 00:01:01:014 01.01.92 Event ID: 16# F360:B283 Additional information 4 / 5: 16# 00 00 Additional information 1 / 2 / 3: 16# 0011 0000 BC17 Operating mode STARTUP reached Incoming event ................................................................................ Event details: 139 of 507 : 00:01:00:992 01.01.92 Event ID: 16# F360:B28E Additional information 4 / 5: 16# 00 00 Additional information 1 / 2 / 3: 16# 1011 0000 0000 Operating mode transition from STOP_U to STARTUP: Start Incoming event ................................................................................ Event details: 140 of 507 : 00:01:00:992 01.01.92 Event ID: 16# F360:B282 Additional information 4 / 5: 16# 00 00 Additional information 1 / 2 / 3: 16# 0010 0000 BC16 Operating mode STOP_U reached Incoming event ................................................................................ Event details: 141 of 507 : 00:01:00:958 01.01.92 Event ID: 16# F360:B28C Additional information 4 / 5: 16# 00 00 Additional information 1 / 2 / 3: 16# 0310 0000 0000 Operating mode transition from STOP to STOP_U: Start Incoming event ................................................................................ Event details: 142 of 507 : 00:01:00:946 01.01.92 Event ID: 16# F360:B281 Additional information 4 / 5: 16# 00 00 Additional information 1 / 2 / 3: 16# 0003 0000 BC03 Operating mode STOP reached Incoming event ................................................................................ Event details: 143 of 507 : 00:01:00:822 01.01.92 Event ID: 16# F360:BF90 Additional information 4 / 5: 16# 00 00 Additional information 1 / 2 / 3: 16# 0000 0000 3BF9 Retain data segment recovered from back-up copy Information 11202 v_savedat, segment 2: Retain data restored Incoming event ................................................................................ Event details: 144 of 507 : 00:01:00:778 01.01.92 Event ID: 16# F360:BF90 Additional information 4 / 5: 16# 00 00 Additional information 1 / 2 / 3: 16# 0000 0000 3BF8 Retain data segment recovered from back-up copy Information 11202 v_konfig, segment 2: Retain data restored Incoming event ................................................................................ Event details: 145 of 507 : 00:01:00:590 01.01.92 Event ID: 16# F360:BF90 Additional information 4 / 5: 16# 00 00 Additional information 1 / 2 / 3: 16# 0000 0000 3BF7 Retain data segment recovered from back-up copy Information 11202 v_global, segment 2: Retain data restored Incoming event ................................................................................ Event details: 146 of 507 : 00:01:00:482 01.01.92 Event ID: 16# F360:BF90 Additional information 4 / 5: 16# 00 00 Additional information 1 / 2 / 3: 16# 0000 0000 3BF6 Retain data segment recovered from back-up copy Information 11202 v_bo, segment 2: Retain data restored Incoming event ................................................................................ Event details: 147 of 507 : 00:01:00:446 01.01.92 Event ID: 16# F360:BF90 Additional information 4 / 5: 16# 00 00 Additional information 1 / 2 / 3: 16# 0000 0000 3BF5 Retain data segment recovered from back-up copy Information 11202 v_baum, segment 2: Retain data restored Incoming event ................................................................................ Event details: 148 of 507 : 00:00:56:742 01.01.92 Event ID: 16# F360:B68B Additional information 4 / 5: 16# 00 50 Additional information 1 / 2 / 3: 16# 0003 0000 0001 Loading user program, mode: 3 Incoming event ................................................................................ Event details: 149 of 507 : 00:00:28:764 01.01.92 Event ID: 16# F260:B410 Additional information 4 / 5: 16# C0 50 Additional information 1 / 2 / 3: 16# 0028 0000 0001 PROFIBUS-DP 1: Station recovery, station 40 Outgoing event ................................................................................ Event details: 150 of 507 : 00:00:28:744 01.01.92 Event ID: 16# F260:B40E Additional information 4 / 5: 16# C0 50 Additional information 1 / 2 / 3: 16# 0028 0000 0001 PROFIBUS-DP 1: Module ok, station: 40, slot: 0 Outgoing event ................................................................................ Event details: 151 of 507 : 00:00:28:034 01.01.92 Event ID: 16# F260:B410 Additional information 4 / 5: 16# C0 50 Additional information 1 / 2 / 3: 16# 0035 0000 0002 PROFIBUS-DP 2: Station recovery, station 53 Outgoing event ................................................................................ Event details: 152 of 507 : 00:00:28:014 01.01.92 Event ID: 16# F260:B40E Additional information 4 / 5: 16# C0 50 Additional information 1 / 2 / 3: 16# 0035 0000 0002 PROFIBUS-DP 2: Module ok, station: 53, slot: 0 Outgoing event ................................................................................ Event details: 153 of 507 : 00:00:28:004 01.01.92 Event ID: 16# F360:B28B Additional information 4 / 5: 16# 00 00 Additional information 1 / 2 / 3: 16# 0103 0000 0000 Operating mode transition from INIT to STOP: Start Incoming event ................................................................................ Event details: 154 of 507 : 00:00:28:004 01.01.92 Event ID: 16# F360:B280 Additional information 4 / 5: 16# 00 00 Additional information 1 / 2 / 3: 16# 0001 0000 BC01 Operating mode INIT reached Incoming event ................................................................................ Event details: 155 of 507 : 00:00:00:000 01.01.92 Event ID: 16# F360:B486 Additional information 4 / 5: 16# 00 00 Additional information 1 / 2 / 3: 16# FFFF 0000 0000 SINAMICS and PROFIBUS software loaded and started Incoming event ................................................................................ Event details: 156 of 507 : 00:00:00:000 01.01.92 Event ID: 16# F260:B815 Additional information 4 / 5: 16# 00 00 Additional information 1 / 2 / 3: 16# 0000 0000 0000 Device with battery module Outgoing event ................................................................................ Event details: 157 of 507 : 00:00:00:000 01.01.92 Event ID: 16# F360:B813 Additional information 4 / 5: 16# 00 00 Additional information 1 / 2 / 3: 16# 0000 0000 0000 Persistent data loaded from file Incoming event ................................................................................ Event details: 158 of 507 : 00:00:00:000 01.01.92 Event ID: 16# F360:B486 Additional information 4 / 5: 16# 00 00 Additional information 1 / 2 / 3: 16# FFFF 0000 0000 SINAMICS and PROFIBUS software loaded and started Incoming event ................................................................................ Event details: 159 of 507 : 00:00:00:000 01.01.92 Event ID: 16# F360:B81B Additional information 4 / 5: 16# 00 00 Additional information 1 / 2 / 3: 16# 0000 0000 0000 Initialization of the persistent data - reason: start-up mode 1 Incoming event ................................................................................ Event details: 160 of 507 : 00:00:00:000 01.01.92 Event ID: 16# F260:B815 Additional information 4 / 5: 16# 00 00 Additional information 1 / 2 / 3: 16# 0000 0000 0000 Device with battery module Outgoing event ................................................................................ Event details: 161 of 507 : 06:36:03:210 13.04.20 Event ID: 16# F360:BF80 Additional information 4 / 5: 16# 00 53 Additional information 1 / 2 / 3: 16# 4E25 0000 3BF4 Technological alarm A_HA: Alarm Error 20005 : Device type:1, log. address:1144 faulted. (Bit:0, encoder number:0, reason: 0x4h) Incoming event ................................................................................ Event details: 162 of 507 : 06:35:20:914 13.04.20 Event ID: 16# F260:B410 Additional information 4 / 5: 16# C0 50 Additional information 1 / 2 / 3: 16# 000F 0000 0003 PROFIBUS-DP 3: Station recovery, station 15 Outgoing event ................................................................................ Event details: 163 of 507 : 06:35:20:904 13.04.20 Event ID: 16# F260:B410 Additional information 4 / 5: 16# C0 50 Additional information 1 / 2 / 3: 16# 0003 0000 0003 PROFIBUS-DP 3: Station recovery, station 3 Outgoing event ................................................................................ Event details: 164 of 507 : 06:34:42:658 13.04.20 Event ID: 16# F360:B284 Additional information 4 / 5: 16# 00 00 Additional information 1 / 2 / 3: 16# 0008 0000 BC08 Operating mode RUN reached Incoming event ................................................................................ Event details: 165 of 507 : 06:34:42:616 13.04.20 Event ID: 16# F360:B290 Additional information 4 / 5: 16# 00 00 Additional information 1 / 2 / 3: 16# 1108 0000 0000 Operating mode transition from STARTUP to RUN: Start Incoming event ................................................................................ Event details: 166 of 507 : 06:34:42:614 13.04.20 Event ID: 16# F360:B283 Additional information 4 / 5: 16# 00 00 Additional information 1 / 2 / 3: 16# 0011 0000 BC17 Operating mode STARTUP reached Incoming event ................................................................................ Event details: 167 of 507 : 06:34:42:592 13.04.20 Event ID: 16# F360:B28E Additional information 4 / 5: 16# 00 00 Additional information 1 / 2 / 3: 16# 1011 0000 0000 Operating mode transition from STOP_U to STARTUP: Start Incoming event ................................................................................ Event details: 168 of 507 : 06:34:42:592 13.04.20 Event ID: 16# F360:B282 Additional information 4 / 5: 16# 00 00 Additional information 1 / 2 / 3: 16# 0010 0000 BC16 Operating mode STOP_U reached Incoming event ................................................................................ Event details: 169 of 507 : 06:34:42:558 13.04.20 Event ID: 16# F360:B28C Additional information 4 / 5: 16# 00 00 Additional information 1 / 2 / 3: 16# 0310 0000 0000 Operating mode transition from STOP to STOP_U: Start Incoming event ................................................................................ Event details: 170 of 507 : 06:34:42:546 13.04.20 Event ID: 16# F360:B281 Additional information 4 / 5: 16# 00 00 Additional information 1 / 2 / 3: 16# 0003 0000 BC03 Operating mode STOP reached Incoming event ................................................................................ Event details: 171 of 507 : 06:34:38:536 13.04.20 Event ID: 16# F360:B68B Additional information 4 / 5: 16# 00 50 Additional information 1 / 2 / 3: 16# 0003 0000 0001 Loading user program, mode: 3 Incoming event ................................................................................ Event details: 172 of 507 : 06:34:11:764 13.04.20 Event ID: 16# F260:B410 Additional information 4 / 5: 16# C0 50 Additional information 1 / 2 / 3: 16# 0028 0000 0001 PROFIBUS-DP 1: Station recovery, station 40 Outgoing event ................................................................................ Event details: 173 of 507 : 06:34:11:744 13.04.20 Event ID: 16# F260:B40E Additional information 4 / 5: 16# C0 50 Additional information 1 / 2 / 3: 16# 0028 0000 0001 PROFIBUS-DP 1: Module ok, station: 40, slot: 0 Outgoing event ................................................................................ Event details: 174 of 507 : 06:34:11:034 13.04.20 Event ID: 16# F260:B410 Additional information 4 / 5: 16# C0 50 Additional information 1 / 2 / 3: 16# 0035 0000 0002 PROFIBUS-DP 2: Station recovery, station 53 Outgoing event ................................................................................ Event details: 175 of 507 : 06:34:11:014 13.04.20 Event ID: 16# F260:B40E Additional information 4 / 5: 16# C0 50 Additional information 1 / 2 / 3: 16# 0035 0000 0002 PROFIBUS-DP 2: Module ok, station: 53, slot: 0 Outgoing event ................................................................................ Event details: 176 of 507 : 06:34:11:004 13.04.20 Event ID: 16# F360:B28B Additional information 4 / 5: 16# 00 00 Additional information 1 / 2 / 3: 16# 0103 0000 0000 Operating mode transition from INIT to STOP: Start Incoming event ................................................................................ Event details: 177 of 507 : 06:34:11:004 13.04.20 Event ID: 16# F360:B280 Additional information 4 / 5: 16# 00 00 Additional information 1 / 2 / 3: 16# 0001 0000 BC01 Operating mode INIT reached Incoming event ................................................................................ Event details: 178 of 507 : 06:33:26:000 13.04.20 Event ID: 16# F360:B486 Additional information 4 / 5: 16# 00 00 Additional information 1 / 2 / 3: 16# FFFF 0000 0000 SINAMICS and PROFIBUS software loaded and started Incoming event ................................................................................ Event details: 179 of 507 : 06:33:26:000 13.04.20 Event ID: 16# F260:B815 Additional information 4 / 5: 16# 00 00 Additional information 1 / 2 / 3: 16# 0000 0000 0000 Device with battery module Outgoing event ................................................................................ Event details: 180 of 507 : 06:30:34:814 13.04.20 Event ID: 16# F360:BF80 Additional information 4 / 5: 16# 00 53 Additional information 1 / 2 / 3: 16# 4E25 0000 3BF3 Technological alarm A_SL_YR: Alarm Error 20005 : Device type:1, log. address:386 faulted. (Bit:0, encoder number:0, reason: 0x8001h) Incoming event ................................................................................ Event details: 181 of 507 : 06:30:34:814 13.04.20 Event ID: 16# F360:BF80 Additional information 4 / 5: 16# 00 53 Additional information 1 / 2 / 3: 16# 4E25 0000 3BF2 Technological alarm A_SL_YL: Alarm Error 20005 : Device type:1, log. address:406 faulted. (Bit:0, encoder number:0, reason: 0x8001h) Incoming event ................................................................................ Event details: 182 of 507 : 06:30:34:814 13.04.20 Event ID: 16# F360:BF80 Additional information 4 / 5: 16# 00 53 Additional information 1 / 2 / 3: 16# 4E25 0000 3BF1 Technological alarm A_WA2: Alarm Error 20005 : Device type:1, log. address:366 faulted. (Bit:0, encoder number:0, reason: 0x8001h) Incoming event ................................................................................ Event details: 183 of 507 : 06:30:34:814 13.04.20 Event ID: 16# F360:BF80 Additional information 4 / 5: 16# 00 53 Additional information 1 / 2 / 3: 16# 4E25 0000 3BF0 Technological alarm A_WA1: Alarm Error 20005 : Device type:1, log. address:338 faulted. (Bit:0, encoder number:0, reason: 0x8001h) Incoming event ................................................................................ Event details: 184 of 507 : 06:30:34:814 13.04.20 Event ID: 16# F360:BF80 Additional information 4 / 5: 16# 00 53 Additional information 1 / 2 / 3: 16# 4E25 0000 3BEF Technological alarm A_FZ3: Alarm Error 20005 : Device type:1, log. address:310 faulted. (Bit:0, encoder number:0, reason: 0x8001h) Incoming event ................................................................................ Event details: 185 of 507 : 06:30:34:814 13.04.20 Event ID: 16# F360:BF80 Additional information 4 / 5: 16# 00 53 Additional information 1 / 2 / 3: 16# 4E25 0000 3BEE Technological alarm A_FZ2: Alarm Error 20005 : Device type:1, log. address:264 faulted. (Bit:0, encoder number:0, reason: 0x8001h) Incoming event ................................................................................ Event details: 186 of 507 : 06:30:34:804 13.04.20 Event ID: 16# F360:B40F Additional information 4 / 5: 16# C0 50 Additional information 1 / 2 / 3: 16# 0028 0000 0001 PROFIBUS-DP 1: Station failure, station 40 Incoming event ................................................................................ Event details: 187 of 507 : 06:30:34:782 13.04.20 Event ID: 16# F360:BF80 Additional information 4 / 5: 16# 00 53 Additional information 1 / 2 / 3: 16# 4E25 0000 3BED Technological alarm A_SL_YL: Alarm Error 20005 : Device type:1, log. address:406 faulted. (Bit:0, encoder number:0, reason: 0x1h) Incoming event ................................................................................ Event details: 188 of 507 : 06:30:34:782 13.04.20 Event ID: 16# F360:BF80 Additional information 4 / 5: 16# 00 53 Additional information 1 / 2 / 3: 16# 4E25 0000 3BEC Technological alarm A_SL_X: Alarm Error 20005 : Device type:1, log. address:284 faulted. (Bit:0, encoder number:0, reason: 0x1h) Incoming event ................................................................................ Event details: 189 of 507 : 06:30:34:782 13.04.20 Event ID: 16# F360:BF80 Additional information 4 / 5: 16# 00 53 Additional information 1 / 2 / 3: 16# 4E25 0000 3BEB Technological alarm A_WA2: Alarm Error 20005 : Device type:1, log. address:366 faulted. (Bit:0, encoder number:0, reason: 0x1h) Incoming event ................................................................................ Event details: 190 of 507 : 06:30:34:782 13.04.20 Event ID: 16# F360:BF80 Additional information 4 / 5: 16# 00 53 Additional information 1 / 2 / 3: 16# 4E25 0000 3BEA Technological alarm A_FZ3: Alarm Error 20005 : Device type:1, log. address:310 faulted. (Bit:0, encoder number:0, reason: 0x1h) Incoming event ................................................................................ Event details: 191 of 507 : 06:30:34:782 13.04.20 Event ID: 16# F360:BF80 Additional information 4 / 5: 16# 00 53 Additional information 1 / 2 / 3: 16# 4E25 0000 3BE9 Technological alarm A_HA: Alarm Error 20005 : Device type:1, log. address:1144 faulted. (Bit:0, encoder number:0, reason: 0x1h) Incoming event ................................................................................ Event details: 192 of 507 : 06:30:34:782 13.04.20 Event ID: 16# F360:BF80 Additional information 4 / 5: 16# 00 53 Additional information 1 / 2 / 3: 16# 4E25 0000 3BE8 Technological alarm A_SL_X: Alarm Error 20005 : Device type:2, log. address:284 faulted. (Bit:0, encoder number:0, reason: 0x200h) Incoming event ................................................................................ Event details: 193 of 507 : 06:30:34:782 13.04.20 Event ID: 16# F360:BF80 Additional information 4 / 5: 16# 00 53 Additional information 1 / 2 / 3: 16# 4E25 0000 3BE7 Technological alarm A_HA: Alarm Error 20005 : Device type:2, log. address:1144 faulted. (Bit:0, encoder number:0, reason: 0x200h) Incoming event ................................................................................ Event details: 194 of 507 : 06:30:34:778 13.04.20 Event ID: 16# F360:BF80 Additional information 4 / 5: 16# 00 53 Additional information 1 / 2 / 3: 16# 4E25 0000 3BE6 Technological alarm A_SL_YR: Alarm Error 20005 : Device type:1, log. address:386 faulted. (Bit:0, encoder number:0, reason: 0x1h) Incoming event ................................................................................ Event details: 195 of 507 : 06:30:34:778 13.04.20 Event ID: 16# F360:BF80 Additional information 4 / 5: 16# 00 53 Additional information 1 / 2 / 3: 16# 4E25 0000 3BE5 Technological alarm A_WA1: Alarm Error 20005 : Device type:1, log. address:338 faulted. (Bit:0, encoder number:0, reason: 0x1h) Incoming event ................................................................................ Event details: 196 of 507 : 06:30:34:778 13.04.20 Event ID: 16# F360:BF80 Additional information 4 / 5: 16# 00 53 Additional information 1 / 2 / 3: 16# 4E25 0000 3BE4 Technological alarm A_FZ2: Alarm Error 20005 : Device type:1, log. address:264 faulted. (Bit:0, encoder number:0, reason: 0x1h) Incoming event ................................................................................ Event details: 197 of 507 : 06:30:34:778 13.04.20 Event ID: 16# F360:BF80 Additional information 4 / 5: 16# 00 53 Additional information 1 / 2 / 3: 16# 4E25 0000 3BE3 Technological alarm A_STK_L: Alarm Error 20005 : Device type:1, log. address:992 faulted. (Bit:0, encoder number:0, reason: 0x1h) Incoming event ................................................................................ Event details: 198 of 507 : 06:30:34:778 13.04.20 Event ID: 16# F360:BF80 Additional information 4 / 5: 16# 00 53 Additional information 1 / 2 / 3: 16# 4E25 0000 3BE2 Technological alarm A_STK_R: Alarm Error 20005 : Device type:1, log. address:966 faulted. (Bit:0, encoder number:0, reason: 0x1h) Incoming event ................................................................................ Event details: 199 of 507 : 06:30:34:778 13.04.20 Event ID: 16# F360:BF80 Additional information 4 / 5: 16# 00 53 Additional information 1 / 2 / 3: 16# 4E25 0000 3BE1 Technological alarm Incoming event ................................................................................ Event details: 200 of 507 : 06:30:34:778 13.04.20 Event ID: 16# F360:BF80 Additional information 4 / 5: 16# 00 53 Additional information 1 / 2 / 3: 16# 4E25 0000 3BE0 Technological alarm Incoming event ................................................................................ Event details: 201 of 507 : 22:02:08:836 03.01.92 Event ID: 16# F360:B305 Additional information 4 / 5: 16# 00 50 Additional information 1 / 2 / 3: 16# 0003 0000 0000 >>>>>>>>>>>> Sinamics Integrated: Start diagnostic buffer, station address = 3 >>>>>>>>>>>> Incoming event ................................................................................ Event details: 202 of 507 : 17:19:51:318 16.09.96 Event ID: 16# F360:240C Additional information 4 / 5: 16# 00 00 Additional information 1 / 2 / 3: 16# 0000 0000 0000 Ramp-up completed, cyclic operation Incoming event ................................................................................ Event details: 203 of 507 : 17:19:43:610 16.09.96 Event ID: 16# F360:240B Additional information 4 / 5: 16# 00 00 Additional information 1 / 2 / 3: 16# 029E 0000 0000 Ramp-up state r3988 = 670 reached Incoming event ................................................................................ Event details: 204 of 507 : 17:19:30:544 16.09.96 Event ID: 16# F360:240B Additional information 4 / 5: 16# 00 00 Additional information 1 / 2 / 3: 16# 02A8 0000 0000 Ramp-up state r3988 = 680 reached Incoming event ................................................................................ Event details: 205 of 507 : 17:19:28:432 16.09.96 Event ID: 16# F360:2416 Additional information 4 / 5: 16# 00 00 Additional information 1 / 2 / 3: 16# 0000 0000 0000 Cyclic data exchange PZD IF1 started Incoming event ................................................................................ Event details: 206 of 507 : 17:19:28:400 16.09.96 Event ID: 16# F360:2418 Additional information 4 / 5: 16# 00 00 Additional information 1 / 2 / 3: 16# 0000 0000 0000 Cyclic data exchange PZD IF1 completed Incoming event ................................................................................ Event details: 207 of 507 : 17:19:04:042 16.09.96 Event ID: 16# F360:2400 Additional information 4 / 5: 16# 00 00 Additional information 1 / 2 / 3: 16# 0000 0000 0000 Power On Incoming event ................................................................................ Event details: 208 of 507 : 17:19:01:082 16.09.96 Event ID: 16# F360:2420 Additional information 4 / 5: 16# 00 00 Additional information 1 / 2 / 3: 16# 7C8D 0000 1121 Fault DO 6: Fault number 31885, fault value 0x1121 Incoming event ................................................................................ Event details: 209 of 507 : 17:14:48:402 16.09.96 Event ID: 16# F360:241C Additional information 4 / 5: 16# 00 00 Additional information 1 / 2 / 3: 16# 0776 0000 0000 Fault DO 2: Fault number 1910, fault value 0x0 Incoming event ................................................................................ Event details: 210 of 507 : 17:14:48:258 16.09.96 Event ID: 16# F360:241B Additional information 4 / 5: 16# 00 00 Additional information 1 / 2 / 3: 16# 077B 0000 0000 Fault DO 1: Fault number 1915, fault value 0x0 Incoming event ................................................................................ Event details: 211 of 507 : 17:14:48:145 16.09.96 Event ID: 16# F360:241D Additional information 4 / 5: 16# 00 00 Additional information 1 / 2 / 3: 16# 0776 0000 0000 Fault DO 3: Fault number 1910, fault value 0x0 Incoming event ................................................................................ Event details: 212 of 507 : 17:14:48:001 16.09.96 Event ID: 16# F360:241D Additional information 4 / 5: 16# 00 00 Additional information 1 / 2 / 3: 16# 0778 0000 0000 Fault DO 3: Fault number 1912, fault value 0x0 Incoming event ................................................................................ Event details: 213 of 507 : 17:14:47:857 16.09.96 Event ID: 16# F360:241D Additional information 4 / 5: 16# 00 00 Additional information 1 / 2 / 3: 16# 077B 0000 0000 Fault DO 3: Fault number 1915, fault value 0x0 Incoming event ................................................................................ Event details: 214 of 507 : 17:14:47:761 16.09.96 Event ID: 16# F360:241E Additional information 4 / 5: 16# 00 00 Additional information 1 / 2 / 3: 16# 0776 0000 0000 Fault DO 4: Fault number 1910, fault value 0x0 Incoming event ................................................................................ Event details: 215 of 507 : 17:14:47:641 16.09.96 Event ID: 16# F360:241E Additional information 4 / 5: 16# 00 00 Additional information 1 / 2 / 3: 16# 0778 0000 0000 Fault DO 4: Fault number 1912, fault value 0x0 Incoming event ................................................................................ Event details: 216 of 507 : 17:14:47:538 16.09.96 Event ID: 16# F360:241F Additional information 4 / 5: 16# 00 00 Additional information 1 / 2 / 3: 16# 0776 0000 0000 Fault DO 5: Fault number 1910, fault value 0x0 Incoming event ................................................................................ Event details: 217 of 507 : 17:14:47:409 16.09.96 Event ID: 16# F360:241F Additional information 4 / 5: 16# 00 00 Additional information 1 / 2 / 3: 16# 0778 0000 0000 Fault DO 5: Fault number 1912, fault value 0x0 Incoming event ................................................................................ Event details: 218 of 507 : 17:14:47:298 16.09.96 Event ID: 16# F360:2420 Additional information 4 / 5: 16# 00 00 Additional information 1 / 2 / 3: 16# 0776 0000 0000 Fault DO 6: Fault number 1910, fault value 0x0 Incoming event ................................................................................ Event details: 219 of 507 : 17:14:47:137 16.09.96 Event ID: 16# F360:2420 Additional information 4 / 5: 16# 00 00 Additional information 1 / 2 / 3: 16# 0778 0000 0000 Fault DO 6: Fault number 1912, fault value 0x0 Incoming event ................................................................................ Event details: 220 of 507 : 17:11:36:049 16.09.96 Event ID: 16# F360:2412 Additional information 4 / 5: 16# 00 00 Additional information 1 / 2 / 3: 16# 0003 0000 0000 Commissioning DO 3: New status P0010 = 0 Incoming event ................................................................................ Event details: 221 of 507 : 17:10:55:425 16.09.96 Event ID: 16# F360:2412 Additional information 4 / 5: 16# 00 00 Additional information 1 / 2 / 3: 16# 0003 0004 0000 Commissioning DO 3: New status P0010 = 4 Incoming event ................................................................................ Event details: 222 of 507 : 17:09:06:313 16.09.96 Event ID: 16# F360:241D Additional information 4 / 5: 16# 00 00 Additional information 1 / 2 / 3: 16# 1CF6 0000 0000 Fault DO 3: Fault number 7414, fault value 0x0 Incoming event ................................................................................ Event details: 223 of 507 : 17:02:07:489 16.09.96 Event ID: 16# F360:241E Additional information 4 / 5: 16# 00 00 Additional information 1 / 2 / 3: 16# 0776 0000 0000 Fault DO 4: Fault number 1910, fault value 0x0 Incoming event ................................................................................ Event details: 224 of 507 : 17:02:07:377 16.09.96 Event ID: 16# F360:241E Additional information 4 / 5: 16# 00 00 Additional information 1 / 2 / 3: 16# 0778 0000 0000 Fault DO 4: Fault number 1912, fault value 0x0 Incoming event ................................................................................ Event details: 225 of 507 : 17:02:07:201 16.09.96 Event ID: 16# F360:241F Additional information 4 / 5: 16# 00 00 Additional information 1 / 2 / 3: 16# 0776 0000 0000 Fault DO 5: Fault number 1910, fault value 0x0 Incoming event ................................................................................ Event details: 226 of 507 : 17:02:07:074 16.09.96 Event ID: 16# F360:241F Additional information 4 / 5: 16# 00 00 Additional information 1 / 2 / 3: 16# 0778 0000 0000 Fault DO 5: Fault number 1912, fault value 0x0 Incoming event ................................................................................ Event details: 227 of 507 : 17:02:06:882 16.09.96 Event ID: 16# F360:2420 Additional information 4 / 5: 16# 00 00 Additional information 1 / 2 / 3: 16# 0776 0000 0000 Fault DO 6: Fault number 1910, fault value 0x0 Incoming event ................................................................................ Event details: 228 of 507 : 17:02:06:753 16.09.96 Event ID: 16# F360:2420 Additional information 4 / 5: 16# 00 00 Additional information 1 / 2 / 3: 16# 0778 0000 0000 Fault DO 6: Fault number 1912, fault value 0x0 Incoming event ................................................................................ Event details: 229 of 507 : 17:02:06:577 16.09.96 Event ID: 16# F360:241B Additional information 4 / 5: 16# 00 00 Additional information 1 / 2 / 3: 16# 077B 0000 0000 Fault DO 1: Fault number 1915, fault value 0x0 Incoming event ................................................................................ Event details: 230 of 507 : 17:02:06:441 16.09.96 Event ID: 16# F360:241C Additional information 4 / 5: 16# 00 00 Additional information 1 / 2 / 3: 16# 0776 0000 0000 Fault DO 2: Fault number 1910, fault value 0x0 Incoming event ................................................................................ Event details: 231 of 507 : 17:02:06:249 16.09.96 Event ID: 16# F360:241D Additional information 4 / 5: 16# 00 00 Additional information 1 / 2 / 3: 16# 0776 0000 0000 Fault DO 3: Fault number 1910, fault value 0x0 Incoming event ................................................................................ Event details: 232 of 507 : 17:02:06:145 16.09.96 Event ID: 16# F360:241D Additional information 4 / 5: 16# 00 00 Additional information 1 / 2 / 3: 16# 0778 0000 0000 Fault DO 3: Fault number 1912, fault value 0x0 Incoming event ................................................................................ Event details: 233 of 507 : 17:02:06:049 16.09.96 Event ID: 16# F360:241D Additional information 4 / 5: 16# 00 00 Additional information 1 / 2 / 3: 16# 077B 0000 0000 Fault DO 3: Fault number 1915, fault value 0x0 Incoming event ................................................................................ Event details: 234 of 507 : 17:00:30:010 16.09.96 Event ID: 16# F360:240C Additional information 4 / 5: 16# 00 00 Additional information 1 / 2 / 3: 16# 0000 0000 0000 Ramp-up completed, cyclic operation Incoming event ................................................................................ Event details: 235 of 507 : 17:00:21:554 16.09.96 Event ID: 16# F360:240B Additional information 4 / 5: 16# 00 00 Additional information 1 / 2 / 3: 16# 029E 0000 0000 Ramp-up state r3988 = 670 reached Incoming event ................................................................................ Event details: 236 of 507 : 17:00:07:989 16.09.96 Event ID: 16# F360:240B Additional information 4 / 5: 16# 00 00 Additional information 1 / 2 / 3: 16# 02A8 0000 0000 Ramp-up state r3988 = 680 reached Incoming event ................................................................................ Event details: 237 of 507 : 17:00:06:437 16.09.96 Event ID: 16# F360:2416 Additional information 4 / 5: 16# 00 00 Additional information 1 / 2 / 3: 16# 0000 0000 0000 Cyclic data exchange PZD IF1 started Incoming event ................................................................................ Event details: 238 of 507 : 17:00:06:413 16.09.96 Event ID: 16# F360:2418 Additional information 4 / 5: 16# 00 00 Additional information 1 / 2 / 3: 16# 0000 0000 0000 Cyclic data exchange PZD IF1 completed Incoming event ................................................................................ Event details: 239 of 507 : 16:59:42:029 16.09.96 Event ID: 16# F360:2400 Additional information 4 / 5: 16# 00 00 Additional information 1 / 2 / 3: 16# 0000 0000 0000 Power On Incoming event ................................................................................ Event details: 240 of 507 : 16:59:39:008 16.09.96 Event ID: 16# F360:2456 Additional information 4 / 5: 16# 00 00 Additional information 1 / 2 / 3: 16# 9F93 0000 C70A Fault DO 60: Fault number 40851, fault value 0xc70a Incoming event ................................................................................ Event details: 241 of 507 : 16:42:17:812 16.09.96 Event ID: 16# F360:240C Additional information 4 / 5: 16# 00 00 Additional information 1 / 2 / 3: 16# 0000 0000 0000 Ramp-up completed, cyclic operation Incoming event ................................................................................ Event details: 242 of 507 : 16:42:09:630 16.09.96 Event ID: 16# F360:240B Additional information 4 / 5: 16# 00 00 Additional information 1 / 2 / 3: 16# 029E 0000 0000 Ramp-up state r3988 = 670 reached Incoming event ................................................................................ Event details: 243 of 507 : 16:41:56:126 16.09.96 Event ID: 16# F360:240B Additional information 4 / 5: 16# 00 00 Additional information 1 / 2 / 3: 16# 02A8 0000 0000 Ramp-up state r3988 = 680 reached Incoming event ................................................................................ Event details: 244 of 507 : 16:41:54:270 16.09.96 Event ID: 16# F360:2416 Additional information 4 / 5: 16# 00 00 Additional information 1 / 2 / 3: 16# 0000 0000 0000 Cyclic data exchange PZD IF1 started Incoming event ................................................................................ Event details: 245 of 507 : 16:41:54:246 16.09.96 Event ID: 16# F360:2418 Additional information 4 / 5: 16# 00 00 Additional information 1 / 2 / 3: 16# 0000 0000 0000 Cyclic data exchange PZD IF1 completed Incoming event ................................................................................ Event details: 246 of 507 : 16:41:30:059 16.09.96 Event ID: 16# F360:2400 Additional information 4 / 5: 16# 00 00 Additional information 1 / 2 / 3: 16# 0000 0000 0000 Power On Incoming event ................................................................................ Event details: 247 of 507 : 16:41:27:434 16.09.96 Event ID: 16# F360:2456 Additional information 4 / 5: 16# 00 00 Additional information 1 / 2 / 3: 16# 9F93 0000 C70A Fault DO 60: Fault number 40851, fault value 0xc70a Incoming event ................................................................................ Event details: 248 of 507 : 16:31:23:989 16.09.96 Event ID: 16# F360:240C Additional information 4 / 5: 16# 00 00 Additional information 1 / 2 / 3: 16# 0000 0000 0000 Ramp-up completed, cyclic operation Incoming event ................................................................................ Event details: 249 of 507 : 16:31:16:179 16.09.96 Event ID: 16# F360:240B Additional information 4 / 5: 16# 00 00 Additional information 1 / 2 / 3: 16# 029E 0000 0000 Ramp-up state r3988 = 670 reached Incoming event ................................................................................ Event details: 250 of 507 : 16:31:02:091 16.09.96 Event ID: 16# F360:240B Additional information 4 / 5: 16# 00 00 Additional information 1 / 2 / 3: 16# 02A8 0000 0000 Ramp-up state r3988 = 680 reached Incoming event ................................................................................ Event details: 251 of 507 : 16:31:00:539 16.09.96 Event ID: 16# F360:2416 Additional information 4 / 5: 16# 00 00 Additional information 1 / 2 / 3: 16# 0000 0000 0000 Cyclic data exchange PZD IF1 started Incoming event ................................................................................ Event details: 252 of 507 : 16:31:00:515 16.09.96 Event ID: 16# F360:2418 Additional information 4 / 5: 16# 00 00 Additional information 1 / 2 / 3: 16# 0000 0000 0000 Cyclic data exchange PZD IF1 completed Incoming event ................................................................................ Event details: 253 of 507 : 16:30:36:047 16.09.96 Event ID: 16# F360:2400 Additional information 4 / 5: 16# 00 00 Additional information 1 / 2 / 3: 16# 0000 0000 0000 Power On Incoming event ................................................................................ Event details: 254 of 507 : 16:29:05:719 16.09.96 Event ID: 16# F360:2414 Additional information 4 / 5: 16# 00 00 Additional information 1 / 2 / 3: 16# 0000 0000 0000 Ram2Rom of DO 0 performed Incoming event ................................................................................ Event details: 255 of 507 : 16:28:07:775 16.09.96 Event ID: 16# F360:2413 Additional information 4 / 5: 16# 00 00 Additional information 1 / 2 / 3: 16# 0000 0000 0000 Ram2Rom of DO 0 started Incoming event ................................................................................ Event details: 256 of 507 : 16:27:51:431 16.09.96 Event ID: 16# F360:2414 Additional information 4 / 5: 16# 00 00 Additional information 1 / 2 / 3: 16# 0000 0000 0000 Ram2Rom of DO 0 performed Incoming event ................................................................................ Event details: 257 of 507 : 16:27:42:655 16.09.96 Event ID: 16# F360:2413 Additional information 4 / 5: 16# 00 00 Additional information 1 / 2 / 3: 16# 0007 0000 0000 Ram2Rom of DO 7 started Incoming event ................................................................................ Event details: 258 of 507 : 16:27:32:575 16.09.96 Event ID: 16# F360:2422 Additional information 4 / 5: 16# 00 00 Additional information 1 / 2 / 3: 16# 0672 0000 0BBB Fault DO 8: Fault number 1650, fault value 0xbbb Incoming event ................................................................................ Event details: 259 of 507 : 16:27:19:943 16.09.96 Event ID: 16# F360:2422 Additional information 4 / 5: 16# 00 00 Additional information 1 / 2 / 3: 16# 894E 8000 3F04 Fault DO 8: Fault number 35150, fault value 0x80003f04 Incoming event ................................................................................ Event details: 260 of 507 : 16:24:18:711 16.09.96 Event ID: 16# F360:2422 Additional information 4 / 5: 16# 00 00 Additional information 1 / 2 / 3: 16# 894E 8000 3F04 Fault DO 8: Fault number 35150, fault value 0x80003f04 Incoming event ................................................................................ Event details: 261 of 507 : 16:24:18:655 16.09.96 Event ID: 16# F360:241E Additional information 4 / 5: 16# 00 00 Additional information 1 / 2 / 3: 16# 0640 0000 0000 Fault DO 4: Fault number 1600, fault value 0x0 Incoming event ................................................................................ Event details: 262 of 507 : 16:24:07:104 16.09.96 Event ID: 16# F360:240C Additional information 4 / 5: 16# 00 00 Additional information 1 / 2 / 3: 16# 0000 0000 0000 Ramp-up completed, cyclic operation Incoming event ................................................................................ Event details: 263 of 507 : 16:23:59:338 16.09.96 Event ID: 16# F360:240B Additional information 4 / 5: 16# 00 00 Additional information 1 / 2 / 3: 16# 029E 0000 0000 Ramp-up state r3988 = 670 reached Incoming event ................................................................................ Event details: 264 of 507 : 16:23:14:229 16.09.96 Event ID: 16# F360:240B Additional information 4 / 5: 16# 00 00 Additional information 1 / 2 / 3: 16# 02A8 0000 0000 Ramp-up state r3988 = 680 reached Incoming event ................................................................................ Event details: 265 of 507 : 16:23:14:221 16.09.96 Event ID: 16# F360:2414 Additional information 4 / 5: 16# 00 00 Additional information 1 / 2 / 3: 16# 0000 0000 0000 Ram2Rom of DO 0 performed Incoming event ................................................................................ Event details: 266 of 507 : 16:22:34:413 16.09.96 Event ID: 16# F360:2413 Additional information 4 / 5: 16# 00 00 Additional information 1 / 2 / 3: 16# 0000 0000 0000 Ram2Rom of DO 0 started Incoming event ................................................................................ Event details: 267 of 507 : 16:22:33:141 16.09.96 Event ID: 16# F360:2416 Additional information 4 / 5: 16# 00 00 Additional information 1 / 2 / 3: 16# 0000 0000 0000 Cyclic data exchange PZD IF1 started Incoming event ................................................................................ Event details: 268 of 507 : 16:22:33:117 16.09.96 Event ID: 16# F360:2418 Additional information 4 / 5: 16# 00 00 Additional information 1 / 2 / 3: 16# 0000 0000 0000 Cyclic data exchange PZD IF1 completed Incoming event ................................................................................ Event details: 269 of 507 : 16:22:32:049 16.09.96 Event ID: 16# F360:241D Additional information 4 / 5: 16# 00 00 Additional information 1 / 2 / 3: 16# 0672 0000 07D5 Fault DO 3: Fault number 1650, fault value 0x7d5 Incoming event ................................................................................ Event details: 270 of 507 : 16:22:31:993 16.09.96 Event ID: 16# F360:241E Additional information 4 / 5: 16# 00 00 Additional information 1 / 2 / 3: 16# 0672 0000 07D5 Fault DO 4: Fault number 1650, fault value 0x7d5 Incoming event ................................................................................ Event details: 271 of 507 : 16:22:31:921 16.09.96 Event ID: 16# F360:241F Additional information 4 / 5: 16# 00 00 Additional information 1 / 2 / 3: 16# 0672 0000 07D5 Fault DO 5: Fault number 1650, fault value 0x7d5 Incoming event ................................................................................ Event details: 272 of 507 : 16:22:31:841 16.09.96 Event ID: 16# F360:2420 Additional information 4 / 5: 16# 00 00 Additional information 1 / 2 / 3: 16# 0672 0000 07D5 Fault DO 6: Fault number 1650, fault value 0x7d5 Incoming event ................................................................................ Event details: 273 of 507 : 16:22:23:097 16.09.96 Event ID: 16# F360:2414 Additional information 4 / 5: 16# 00 00 Additional information 1 / 2 / 3: 16# 0000 0000 0000 Ram2Rom of DO 0 performed Incoming event ................................................................................ Event details: 274 of 507 : 16:21:55:786 16.09.96 Event ID: 16# F360:2413 Additional information 4 / 5: 16# 00 00 Additional information 1 / 2 / 3: 16# 0001 0000 0000 Ram2Rom of DO 1 started Incoming event ................................................................................ Event details: 275 of 507 : 16:21:28:617 16.09.96 Event ID: 16# F360:2400 Additional information 4 / 5: 16# 00 00 Additional information 1 / 2 / 3: 16# 0000 0000 0000 Power On Incoming event ................................................................................ Event details: 276 of 507 : 16:20:24:947 16.09.96 Event ID: 16# F360:2422 Additional information 4 / 5: 16# 00 00 Additional information 1 / 2 / 3: 16# 894E 8000 3F04 Fault DO 8: Fault number 35150, fault value 0x80003f04 Incoming event ................................................................................ Event details: 277 of 507 : 16:16:51:731 16.09.96 Event ID: 16# F360:2422 Additional information 4 / 5: 16# 00 00 Additional information 1 / 2 / 3: 16# 894E 8000 3F04 Fault DO 8: Fault number 35150, fault value 0x80003f04 Incoming event ................................................................................ Event details: 278 of 507 : 16:14:46:259 16.09.96 Event ID: 16# F360:2422 Additional information 4 / 5: 16# 00 00 Additional information 1 / 2 / 3: 16# 894E 8000 3F04 Fault DO 8: Fault number 35150, fault value 0x80003f04 Incoming event ................................................................................ Event details: 279 of 507 : 16:13:14:075 16.09.96 Event ID: 16# F360:2422 Additional information 4 / 5: 16# 00 00 Additional information 1 / 2 / 3: 16# 894E 8000 3F04 Fault DO 8: Fault number 35150, fault value 0x80003f04 Incoming event ................................................................................ Event details: 280 of 507 : 16:04:19:003 16.09.96 Event ID: 16# F360:2422 Additional information 4 / 5: 16# 00 00 Additional information 1 / 2 / 3: 16# 894E 8000 3F04 Fault DO 8: Fault number 35150, fault value 0x80003f04 Incoming event ................................................................................ Event details: 281 of 507 : 16:02:26:043 16.09.96 Event ID: 16# F360:2422 Additional information 4 / 5: 16# 00 00 Additional information 1 / 2 / 3: 16# 894E 8000 3F04 Fault DO 8: Fault number 35150, fault value 0x80003f04 Incoming event ................................................................................ Event details: 282 of 507 : 16:00:58:499 16.09.96 Event ID: 16# F360:2422 Additional information 4 / 5: 16# 00 00 Additional information 1 / 2 / 3: 16# 894E 8000 3F04 Fault DO 8: Fault number 35150, fault value 0x80003f04 Incoming event ................................................................................ Event details: 283 of 507 : 15:52:03:467 16.09.96 Event ID: 16# F360:2422 Additional information 4 / 5: 16# 00 00 Additional information 1 / 2 / 3: 16# 894E 8000 3F04 Fault DO 8: Fault number 35150, fault value 0x80003f04 Incoming event ................................................................................ Event details: 284 of 507 : 15:50:10:579 16.09.96 Event ID: 16# F360:2422 Additional information 4 / 5: 16# 00 00 Additional information 1 / 2 / 3: 16# 894E 8000 3F04 Fault DO 8: Fault number 35150, fault value 0x80003f04 Incoming event ................................................................................ Event details: 285 of 507 : 15:46:18:019 16.09.96 Event ID: 16# F360:241E Additional information 4 / 5: 16# 00 00 Additional information 1 / 2 / 3: 16# 7788 0000 270F Fault DO 4: Fault number 30600, fault value 0x270f Incoming event ................................................................................ Event details: 286 of 507 : 15:46:17:419 16.09.96 Event ID: 16# F360:241D Additional information 4 / 5: 16# 00 00 Additional information 1 / 2 / 3: 16# 077B 0000 0000 Fault DO 3: Fault number 1915, fault value 0x0 Incoming event ................................................................................ Event details: 287 of 507 : 15:46:17:275 16.09.96 Event ID: 16# F360:241E Additional information 4 / 5: 16# 00 00 Additional information 1 / 2 / 3: 16# 0776 0000 0000 Fault DO 4: Fault number 1910, fault value 0x0 Incoming event ................................................................................ Event details: 288 of 507 : 15:46:17:083 16.09.96 Event ID: 16# F360:241E Additional information 4 / 5: 16# 00 00 Additional information 1 / 2 / 3: 16# 0778 0000 0000 Fault DO 4: Fault number 1912, fault value 0x0 Incoming event ................................................................................ Event details: 289 of 507 : 15:46:16:891 16.09.96 Event ID: 16# F360:241F Additional information 4 / 5: 16# 00 00 Additional information 1 / 2 / 3: 16# 0776 0000 0000 Fault DO 5: Fault number 1910, fault value 0x0 Incoming event ................................................................................ Event details: 290 of 507 : 15:46:16:747 16.09.96 Event ID: 16# F360:241F Additional information 4 / 5: 16# 00 00 Additional information 1 / 2 / 3: 16# 0778 0000 0000 Fault DO 5: Fault number 1912, fault value 0x0 Incoming event ................................................................................ Event details: 291 of 507 : 15:46:16:587 16.09.96 Event ID: 16# F360:2420 Additional information 4 / 5: 16# 00 00 Additional information 1 / 2 / 3: 16# 0776 0000 0000 Fault DO 6: Fault number 1910, fault value 0x0 Incoming event ................................................................................ Event details: 292 of 507 : 15:46:16:411 16.09.96 Event ID: 16# F360:2420 Additional information 4 / 5: 16# 00 00 Additional information 1 / 2 / 3: 16# 0778 0000 0000 Fault DO 6: Fault number 1912, fault value 0x0 Incoming event ................................................................................ Event details: 293 of 507 : 15:46:16:251 16.09.96 Event ID: 16# F360:241B Additional information 4 / 5: 16# 00 00 Additional information 1 / 2 / 3: 16# 077B 0000 0000 Fault DO 1: Fault number 1915, fault value 0x0 Incoming event ................................................................................ Event details: 294 of 507 : 15:46:16:083 16.09.96 Event ID: 16# F360:241C Additional information 4 / 5: 16# 00 00 Additional information 1 / 2 / 3: 16# 0776 0000 0000 Fault DO 2: Fault number 1910, fault value 0x0 Incoming event ................................................................................ Event details: 295 of 507 : 15:46:15:867 16.09.96 Event ID: 16# F360:241D Additional information 4 / 5: 16# 00 00 Additional information 1 / 2 / 3: 16# 0776 0000 0000 Fault DO 3: Fault number 1910, fault value 0x0 Incoming event ................................................................................ Event details: 296 of 507 : 15:46:15:675 16.09.96 Event ID: 16# F360:241D Additional information 4 / 5: 16# 00 00 Additional information 1 / 2 / 3: 16# 0778 0000 0000 Fault DO 3: Fault number 1912, fault value 0x0 Incoming event ................................................................................ Event details: 297 of 507 : 15:46:15:539 16.09.96 Event ID: 16# F360:241D Additional information 4 / 5: 16# 00 00 Additional information 1 / 2 / 3: 16# 077B 0000 0000 Fault DO 3: Fault number 1915, fault value 0x0 Incoming event ................................................................................ Event details: 298 of 507 : 15:46:15:355 16.09.96 Event ID: 16# F360:241E Additional information 4 / 5: 16# 00 00 Additional information 1 / 2 / 3: 16# 0776 0000 0000 Fault DO 4: Fault number 1910, fault value 0x0 Incoming event ................................................................................ Event details: 299 of 507 : 15:46:15:139 16.09.96 Event ID: 16# F360:241E Additional information 4 / 5: 16# 00 00 Additional information 1 / 2 / 3: 16# 0778 0000 0000 Fault DO 4: Fault number 1912, fault value 0x0 Incoming event ................................................................................ Event details: 300 of 507 : 15:46:14:835 16.09.96 Event ID: 16# F360:241F Additional information 4 / 5: 16# 00 00 Additional information 1 / 2 / 3: 16# 0776 0000 0000 Fault DO 5: Fault number 1910, fault value 0x0 Incoming event ................................................................................ Event details: 301 of 507 : 15:46:14:659 16.09.96 Event ID: 16# F360:241F Additional information 4 / 5: 16# 00 00 Additional information 1 / 2 / 3: 16# 0778 0000 0000 Fault DO 5: Fault number 1912, fault value 0x0 Incoming event ................................................................................ Event details: 302 of 507 : 15:46:14:491 16.09.96 Event ID: 16# F360:2420 Additional information 4 / 5: 16# 00 00 Additional information 1 / 2 / 3: 16# 0776 0000 0000 Fault DO 6: Fault number 1910, fault value 0x0 Incoming event ................................................................................ Event details: 303 of 507 : 15:46:14:323 16.09.96 Event ID: 16# F360:2420 Additional information 4 / 5: 16# 00 00 Additional information 1 / 2 / 3: 16# 0778 0000 0000 Fault DO 6: Fault number 1912, fault value 0x0 Incoming event ................................................................................ Event details: 304 of 507 : 15:46:14:123 16.09.96 Event ID: 16# F360:241B Additional information 4 / 5: 16# 00 00 Additional information 1 / 2 / 3: 16# 077B 0000 0000 Fault DO 1: Fault number 1915, fault value 0x0 Incoming event ................................................................................ Event details: 305 of 507 : 15:46:13:939 16.09.96 Event ID: 16# F360:241C Additional information 4 / 5: 16# 00 00 Additional information 1 / 2 / 3: 16# 0776 0000 0000 Fault DO 2: Fault number 1910, fault value 0x0 Incoming event ................................................................................ Event details: 306 of 507 : 15:46:13:203 16.09.96 Event ID: 16# F360:241B Additional information 4 / 5: 16# 00 00 Additional information 1 / 2 / 3: 16# 077B 0000 0000 Fault DO 1: Fault number 1915, fault value 0x0 Incoming event ................................................................................ Event details: 307 of 507 : 15:46:13:011 16.09.96 Event ID: 16# F360:241C Additional information 4 / 5: 16# 00 00 Additional information 1 / 2 / 3: 16# 0776 0000 0000 Fault DO 2: Fault number 1910, fault value 0x0 Incoming event ................................................................................ Event details: 308 of 507 : 15:46:12:811 16.09.96 Event ID: 16# F360:241D Additional information 4 / 5: 16# 00 00 Additional information 1 / 2 / 3: 16# 0776 0000 0000 Fault DO 3: Fault number 1910, fault value 0x0 Incoming event ................................................................................ Event details: 309 of 507 : 15:46:12:691 16.09.96 Event ID: 16# F360:241D Additional information 4 / 5: 16# 00 00 Additional information 1 / 2 / 3: 16# 0778 0000 0000 Fault DO 3: Fault number 1912, fault value 0x0 Incoming event ................................................................................ Event details: 310 of 507 : 15:46:12:547 16.09.96 Event ID: 16# F360:241D Additional information 4 / 5: 16# 00 00 Additional information 1 / 2 / 3: 16# 077B 0000 0000 Fault DO 3: Fault number 1915, fault value 0x0 Incoming event ................................................................................ Event details: 311 of 507 : 15:46:12:115 16.09.96 Event ID: 16# F360:241E Additional information 4 / 5: 16# 00 00 Additional information 1 / 2 / 3: 16# 0776 0000 0000 Fault DO 4: Fault number 1910, fault value 0x0 Incoming event ................................................................................ Event details: 312 of 507 : 15:46:11:971 16.09.96 Event ID: 16# F360:241E Additional information 4 / 5: 16# 00 00 Additional information 1 / 2 / 3: 16# 0778 0000 0000 Fault DO 4: Fault number 1912, fault value 0x0 Incoming event ................................................................................ Event details: 313 of 507 : 15:46:11:787 16.09.96 Event ID: 16# F360:241F Additional information 4 / 5: 16# 00 00 Additional information 1 / 2 / 3: 16# 0776 0000 0000 Fault DO 5: Fault number 1910, fault value 0x0 Incoming event ................................................................................ Event details: 314 of 507 : 15:46:11:587 16.09.96 Event ID: 16# F360:241F Additional information 4 / 5: 16# 00 00 Additional information 1 / 2 / 3: 16# 0778 0000 0000 Fault DO 5: Fault number 1912, fault value 0x0 Incoming event ................................................................................ Event details: 315 of 507 : 15:41:36:003 16.09.96 Event ID: 16# F360:2422 Additional information 4 / 5: 16# 00 00 Additional information 1 / 2 / 3: 16# 894E 8000 3F04 Fault DO 8: Fault number 35150, fault value 0x80003f04 Incoming event ................................................................................ Event details: 316 of 507 : 15:38:18:827 16.09.96 Event ID: 16# F360:2422 Additional information 4 / 5: 16# 00 00 Additional information 1 / 2 / 3: 16# 894E 8000 3F04 Fault DO 8: Fault number 35150, fault value 0x80003f04 Incoming event ................................................................................ Event details: 317 of 507 : 15:38:12:751 16.09.96 Event ID: 16# F360:2422 Additional information 4 / 5: 16# 00 00 Additional information 1 / 2 / 3: 16# 894E 8000 3F04 Fault DO 8: Fault number 35150, fault value 0x80003f04 Incoming event ................................................................................ Event details: 318 of 507 : 15:38:12:679 16.09.96 Event ID: 16# F360:241E Additional information 4 / 5: 16# 00 00 Additional information 1 / 2 / 3: 16# 0640 0000 0000 Fault DO 4: Fault number 1600, fault value 0x0 Incoming event ................................................................................ Event details: 319 of 507 : 15:38:06:343 16.09.96 Event ID: 16# F360:240C Additional information 4 / 5: 16# 00 00 Additional information 1 / 2 / 3: 16# 0000 0000 0000 Ramp-up completed, cyclic operation Incoming event ................................................................................ Event details: 320 of 507 : 15:38:02:263 16.09.96 Event ID: 16# F360:240B Additional information 4 / 5: 16# 00 00 Additional information 1 / 2 / 3: 16# 029E 0000 0000 Ramp-up state r3988 = 670 reached Incoming event ................................................................................ Event details: 321 of 507 : 15:38:01:496 16.09.96 Event ID: 16# F360:240B Additional information 4 / 5: 16# 00 00 Additional information 1 / 2 / 3: 16# 02A8 0000 0000 Ramp-up state r3988 = 680 reached Incoming event ................................................................................ Event details: 322 of 507 : 15:38:01:480 16.09.96 Event ID: 16# F360:2414 Additional information 4 / 5: 16# 00 00 Additional information 1 / 2 / 3: 16# 0000 0000 0000 Ram2Rom of DO 0 performed Incoming event ................................................................................ Event details: 323 of 507 : 15:37:23:800 16.09.96 Event ID: 16# F360:2413 Additional information 4 / 5: 16# 00 00 Additional information 1 / 2 / 3: 16# 0000 0000 0000 Ram2Rom of DO 0 started Incoming event ................................................................................ Event details: 324 of 507 : 15:37:22:088 16.09.96 Event ID: 16# F360:2416 Additional information 4 / 5: 16# 00 00 Additional information 1 / 2 / 3: 16# 0000 0000 0000 Cyclic data exchange PZD IF1 started Incoming event ................................................................................ Event details: 325 of 507 : 15:37:22:064 16.09.96 Event ID: 16# F360:2418 Additional information 4 / 5: 16# 00 00 Additional information 1 / 2 / 3: 16# 0000 0000 0000 Cyclic data exchange PZD IF1 completed Incoming event ................................................................................ Event details: 326 of 507 : 15:37:21:662 16.09.96 Event ID: 16# F360:241D Additional information 4 / 5: 16# 00 00 Additional information 1 / 2 / 3: 16# 0672 0000 07D5 Fault DO 3: Fault number 1650, fault value 0x7d5 Incoming event ................................................................................ Event details: 327 of 507 : 15:37:21:598 16.09.96 Event ID: 16# F360:241E Additional information 4 / 5: 16# 00 00 Additional information 1 / 2 / 3: 16# 0672 0000 07D5 Fault DO 4: Fault number 1650, fault value 0x7d5 Incoming event ................................................................................ Event details: 328 of 507 : 15:37:21:534 16.09.96 Event ID: 16# F360:241F Additional information 4 / 5: 16# 00 00 Additional information 1 / 2 / 3: 16# 0672 0000 07D5 Fault DO 5: Fault number 1650, fault value 0x7d5 Incoming event ................................................................................ Event details: 329 of 507 : 15:37:21:470 16.09.96 Event ID: 16# F360:2420 Additional information 4 / 5: 16# 00 00 Additional information 1 / 2 / 3: 16# 0672 0000 07D5 Fault DO 6: Fault number 1650, fault value 0x7d5 Incoming event ................................................................................ Event details: 330 of 507 : 15:36:58:429 16.09.96 Event ID: 16# F360:2400 Additional information 4 / 5: 16# 00 00 Additional information 1 / 2 / 3: 16# 0000 0000 0000 Power On Incoming event ................................................................................ Event details: 331 of 507 : 15:36:45:248 16.09.96 Event ID: 16# F360:241F Additional information 4 / 5: 16# 00 00 Additional information 1 / 2 / 3: 16# 78A5 0000 0B21 Fault DO 5: Fault number 30885, fault value 0xb21 Incoming event ................................................................................ Event details: 332 of 507 : 15:36:45:176 16.09.96 Event ID: 16# F360:2420 Additional information 4 / 5: 16# 00 00 Additional information 1 / 2 / 3: 16# 0659 0000 0001 Fault DO 6: Fault number 1625, fault value 0x1 Incoming event ................................................................................ Event details: 333 of 507 : 15:35:45:336 16.09.96 Event ID: 16# F360:2422 Additional information 4 / 5: 16# 00 00 Additional information 1 / 2 / 3: 16# 894E 8000 3F04 Fault DO 8: Fault number 35150, fault value 0x80003f04 Incoming event ................................................................................ Event details: 334 of 507 : 15:35:14:384 16.09.96 Event ID: 16# F360:2412 Additional information 4 / 5: 16# 00 00 Additional information 1 / 2 / 3: 16# 0008 0000 0000 Commissioning DO 8: New status P0010 = 0 Incoming event ................................................................................ Event details: 335 of 507 : 15:35:14:368 16.09.96 Event ID: 16# F360:2412 Additional information 4 / 5: 16# 00 00 Additional information 1 / 2 / 3: 16# 0007 0000 0000 Commissioning DO 7: New status P0010 = 0 Incoming event ................................................................................ Event details: 336 of 507 : 15:35:05:656 16.09.96 Event ID: 16# F360:2414 Additional information 4 / 5: 16# 00 00 Additional information 1 / 2 / 3: 16# 0000 0000 0000 Ram2Rom of DO 0 performed Incoming event ................................................................................ Event details: 337 of 507 : 15:34:58:800 16.09.96 Event ID: 16# F360:2413 Additional information 4 / 5: 16# 00 00 Additional information 1 / 2 / 3: 16# 0007 0000 0000 Ram2Rom of DO 7 started Incoming event ................................................................................ Event details: 338 of 507 : 15:34:50:208 16.09.96 Event ID: 16# F360:2422 Additional information 4 / 5: 16# 00 00 Additional information 1 / 2 / 3: 16# 0672 0000 0BBB Fault DO 8: Fault number 1650, fault value 0xbbb Incoming event ................................................................................ Event details: 339 of 507 : 15:34:23:920 16.09.96 Event ID: 16# F360:2412 Additional information 4 / 5: 16# 00 00 Additional information 1 / 2 / 3: 16# 0008 001E 0000 Commissioning DO 8: New status P0010 = 30 Incoming event ................................................................................ Event details: 340 of 507 : 15:34:23:920 16.09.96 Event ID: 16# F360:2412 Additional information 4 / 5: 16# 00 00 Additional information 1 / 2 / 3: 16# 0007 001E 0000 Commissioning DO 7: New status P0010 = 30 Incoming event ................................................................................ Event details: 341 of 507 : 15:34:01:768 16.09.96 Event ID: 16# F360:2420 Additional information 4 / 5: 16# 00 00 Additional information 1 / 2 / 3: 16# 0778 0000 0000 Fault DO 6: Fault number 1912, fault value 0x0 Incoming event ................................................................................ Event details: 342 of 507 : 15:34:01:552 16.09.96 Event ID: 16# F360:241B Additional information 4 / 5: 16# 00 00 Additional information 1 / 2 / 3: 16# 077B 0000 0000 Fault DO 1: Fault number 1915, fault value 0x0 Incoming event ................................................................................ Event details: 343 of 507 : 15:34:01:360 16.09.96 Event ID: 16# F360:241C Additional information 4 / 5: 16# 00 00 Additional information 1 / 2 / 3: 16# 0776 0000 0000 Fault DO 2: Fault number 1910, fault value 0x0 Incoming event ................................................................................ Event details: 344 of 507 : 15:34:01:160 16.09.96 Event ID: 16# F360:241D Additional information 4 / 5: 16# 00 00 Additional information 1 / 2 / 3: 16# 0776 0000 0000 Fault DO 3: Fault number 1910, fault value 0x0 Incoming event ................................................................................ Event details: 345 of 507 : 15:34:01:016 16.09.96 Event ID: 16# F360:241D Additional information 4 / 5: 16# 00 00 Additional information 1 / 2 / 3: 16# 0778 0000 0000 Fault DO 3: Fault number 1912, fault value 0x0 Incoming event ................................................................................ Event details: 346 of 507 : 15:34:00:864 16.09.96 Event ID: 16# F360:241D Additional information 4 / 5: 16# 00 00 Additional information 1 / 2 / 3: 16# 077B 0000 0000 Fault DO 3: Fault number 1915, fault value 0x0 Incoming event ................................................................................ Event details: 347 of 507 : 15:34:00:704 16.09.96 Event ID: 16# F360:241E Additional information 4 / 5: 16# 00 00 Additional information 1 / 2 / 3: 16# 0776 0000 0000 Fault DO 4: Fault number 1910, fault value 0x0 Incoming event ................................................................................ Event details: 348 of 507 : 15:34:00:520 16.09.96 Event ID: 16# F360:241E Additional information 4 / 5: 16# 00 00 Additional information 1 / 2 / 3: 16# 0778 0000 0000 Fault DO 4: Fault number 1912, fault value 0x0 Incoming event ................................................................................ Event details: 349 of 507 : 15:34:00:392 16.09.96 Event ID: 16# F360:241F Additional information 4 / 5: 16# 00 00 Additional information 1 / 2 / 3: 16# 0776 0000 0000 Fault DO 5: Fault number 1910, fault value 0x0 Incoming event ................................................................................ Event details: 350 of 507 : 15:34:00:256 16.09.96 Event ID: 16# F360:241F Additional information 4 / 5: 16# 00 00 Additional information 1 / 2 / 3: 16# 0778 0000 0000 Fault DO 5: Fault number 1912, fault value 0x0 Incoming event ................................................................................ Event details: 351 of 507 : 15:34:00:120 16.09.96 Event ID: 16# F360:2420 Additional information 4 / 5: 16# 00 00 Additional information 1 / 2 / 3: 16# 0776 0000 0000 Fault DO 6: Fault number 1910, fault value 0x0 Incoming event ................................................................................ Event details: 352 of 507 : 15:33:59:960 16.09.96 Event ID: 16# F360:2420 Additional information 4 / 5: 16# 00 00 Additional information 1 / 2 / 3: 16# 0778 0000 0000 Fault DO 6: Fault number 1912, fault value 0x0 Incoming event ................................................................................ Event details: 353 of 507 : 15:33:59:792 16.09.96 Event ID: 16# F360:241B Additional information 4 / 5: 16# 00 00 Additional information 1 / 2 / 3: 16# 077B 0000 0000 Fault DO 1: Fault number 1915, fault value 0x0 Incoming event ................................................................................ Event details: 354 of 507 : 15:33:59:560 16.09.96 Event ID: 16# F360:241C Additional information 4 / 5: 16# 00 00 Additional information 1 / 2 / 3: 16# 0776 0000 0000 Fault DO 2: Fault number 1910, fault value 0x0 Incoming event ................................................................................ Event details: 355 of 507 : 15:33:59:424 16.09.96 Event ID: 16# F360:241D Additional information 4 / 5: 16# 00 00 Additional information 1 / 2 / 3: 16# 0776 0000 0000 Fault DO 3: Fault number 1910, fault value 0x0 Incoming event ................................................................................ Event details: 356 of 507 : 15:33:59:256 16.09.96 Event ID: 16# F360:241D Additional information 4 / 5: 16# 00 00 Additional information 1 / 2 / 3: 16# 0778 0000 0000 Fault DO 3: Fault number 1912, fault value 0x0 Incoming event ................................................................................ Event details: 357 of 507 : 15:33:59:064 16.09.96 Event ID: 16# F360:241D Additional information 4 / 5: 16# 00 00 Additional information 1 / 2 / 3: 16# 077B 0000 0000 Fault DO 3: Fault number 1915, fault value 0x0 Incoming event ................................................................................ Event details: 358 of 507 : 15:33:58:912 16.09.96 Event ID: 16# F360:241E Additional information 4 / 5: 16# 00 00 Additional information 1 / 2 / 3: 16# 0776 0000 0000 Fault DO 4: Fault number 1910, fault value 0x0 Incoming event ................................................................................ Event details: 359 of 507 : 15:33:58:760 16.09.96 Event ID: 16# F360:241E Additional information 4 / 5: 16# 00 00 Additional information 1 / 2 / 3: 16# 0778 0000 0000 Fault DO 4: Fault number 1912, fault value 0x0 Incoming event ................................................................................ Event details: 360 of 507 : 15:33:58:608 16.09.96 Event ID: 16# F360:241F Additional information 4 / 5: 16# 00 00 Additional information 1 / 2 / 3: 16# 0776 0000 0000 Fault DO 5: Fault number 1910, fault value 0x0 Incoming event ................................................................................ Event details: 361 of 507 : 15:33:58:376 16.09.96 Event ID: 16# F360:241F Additional information 4 / 5: 16# 00 00 Additional information 1 / 2 / 3: 16# 0778 0000 0000 Fault DO 5: Fault number 1912, fault value 0x0 Incoming event ................................................................................ Event details: 362 of 507 : 15:33:58:192 16.09.96 Event ID: 16# F360:2420 Additional information 4 / 5: 16# 00 00 Additional information 1 / 2 / 3: 16# 0776 0000 0000 Fault DO 6: Fault number 1910, fault value 0x0 Incoming event ................................................................................ Event details: 363 of 507 : 15:33:57:872 16.09.96 Event ID: 16# F360:2420 Additional information 4 / 5: 16# 00 00 Additional information 1 / 2 / 3: 16# 0778 0000 0000 Fault DO 6: Fault number 1912, fault value 0x0 Incoming event ................................................................................ Event details: 364 of 507 : 15:33:57:744 16.09.96 Event ID: 16# F360:241B Additional information 4 / 5: 16# 00 00 Additional information 1 / 2 / 3: 16# 077B 0000 0000 Fault DO 1: Fault number 1915, fault value 0x0 Incoming event ................................................................................ Event details: 365 of 507 : 15:33:57:624 16.09.96 Event ID: 16# F360:241C Additional information 4 / 5: 16# 00 00 Additional information 1 / 2 / 3: 16# 0776 0000 0000 Fault DO 2: Fault number 1910, fault value 0x0 Incoming event ................................................................................ Event details: 366 of 507 : 15:33:57:504 16.09.96 Event ID: 16# F360:241D Additional information 4 / 5: 16# 00 00 Additional information 1 / 2 / 3: 16# 0776 0000 0000 Fault DO 3: Fault number 1910, fault value 0x0 Incoming event ................................................................................ Event details: 367 of 507 : 15:33:57:360 16.09.96 Event ID: 16# F360:241D Additional information 4 / 5: 16# 00 00 Additional information 1 / 2 / 3: 16# 0778 0000 0000 Fault DO 3: Fault number 1912, fault value 0x0 Incoming event ................................................................................ Event details: 368 of 507 : 15:33:57:168 16.09.96 Event ID: 16# F360:241D Additional information 4 / 5: 16# 00 00 Additional information 1 / 2 / 3: 16# 077B 0000 0000 Fault DO 3: Fault number 1915, fault value 0x0 Incoming event ................................................................................ Event details: 369 of 507 : 15:33:56:968 16.09.96 Event ID: 16# F360:241E Additional information 4 / 5: 16# 00 00 Additional information 1 / 2 / 3: 16# 0776 0000 0000 Fault DO 4: Fault number 1910, fault value 0x0 Incoming event ................................................................................ Event details: 370 of 507 : 15:33:56:808 16.09.96 Event ID: 16# F360:241E Additional information 4 / 5: 16# 00 00 Additional information 1 / 2 / 3: 16# 0778 0000 0000 Fault DO 4: Fault number 1912, fault value 0x0 Incoming event ................................................................................ Event details: 371 of 507 : 15:33:56:520 16.09.96 Event ID: 16# F360:241E Additional information 4 / 5: 16# 00 00 Additional information 1 / 2 / 3: 16# 7788 0000 270F Fault DO 4: Fault number 30600, fault value 0x270f Incoming event ................................................................................ Event details: 372 of 507 : 15:33:55:888 16.09.96 Event ID: 16# F360:241E Additional information 4 / 5: 16# 00 00 Additional information 1 / 2 / 3: 16# 0776 0000 0000 Fault DO 4: Fault number 1910, fault value 0x0 Incoming event ................................................................................ Event details: 373 of 507 : 15:33:55:720 16.09.96 Event ID: 16# F360:241E Additional information 4 / 5: 16# 00 00 Additional information 1 / 2 / 3: 16# 0778 0000 0000 Fault DO 4: Fault number 1912, fault value 0x0 Incoming event ................................................................................ Event details: 374 of 507 : 15:33:55:568 16.09.96 Event ID: 16# F360:241F Additional information 4 / 5: 16# 00 00 Additional information 1 / 2 / 3: 16# 0776 0000 0000 Fault DO 5: Fault number 1910, fault value 0x0 Incoming event ................................................................................ Event details: 375 of 507 : 15:33:55:376 16.09.96 Event ID: 16# F360:241F Additional information 4 / 5: 16# 00 00 Additional information 1 / 2 / 3: 16# 0778 0000 0000 Fault DO 5: Fault number 1912, fault value 0x0 Incoming event ................................................................................ Event details: 376 of 507 : 15:33:55:152 16.09.96 Event ID: 16# F360:2420 Additional information 4 / 5: 16# 00 00 Additional information 1 / 2 / 3: 16# 0776 0000 0000 Fault DO 6: Fault number 1910, fault value 0x0 Incoming event ................................................................................ Event details: 377 of 507 : 15:33:54:976 16.09.96 Event ID: 16# F360:2420 Additional information 4 / 5: 16# 00 00 Additional information 1 / 2 / 3: 16# 0778 0000 0000 Fault DO 6: Fault number 1912, fault value 0x0 Incoming event ................................................................................ Event details: 378 of 507 : 15:33:54:712 16.09.96 Event ID: 16# F360:241B Additional information 4 / 5: 16# 00 00 Additional information 1 / 2 / 3: 16# 077B 0000 0000 Fault DO 1: Fault number 1915, fault value 0x0 Incoming event ................................................................................ Event details: 379 of 507 : 15:33:54:592 16.09.96 Event ID: 16# F360:241C Additional information 4 / 5: 16# 00 00 Additional information 1 / 2 / 3: 16# 0776 0000 0000 Fault DO 2: Fault number 1910, fault value 0x0 Incoming event ................................................................................ Event details: 380 of 507 : 15:33:54:280 16.09.96 Event ID: 16# F360:241D Additional information 4 / 5: 16# 00 00 Additional information 1 / 2 / 3: 16# 0776 0000 0000 Fault DO 3: Fault number 1910, fault value 0x0 Incoming event ................................................................................ Event details: 381 of 507 : 15:33:54:080 16.09.96 Event ID: 16# F360:241D Additional information 4 / 5: 16# 00 00 Additional information 1 / 2 / 3: 16# 0778 0000 0000 Fault DO 3: Fault number 1912, fault value 0x0 Incoming event ................................................................................ Event details: 382 of 507 : 15:33:53:920 16.09.96 Event ID: 16# F360:241D Additional information 4 / 5: 16# 00 00 Additional information 1 / 2 / 3: 16# 077B 0000 0000 Fault DO 3: Fault number 1915, fault value 0x0 Incoming event ................................................................................ Event details: 383 of 507 : 15:27:10:912 16.09.96 Event ID: 16# F360:2422 Additional information 4 / 5: 16# 00 00 Additional information 1 / 2 / 3: 16# 894E 8000 3F04 Fault DO 8: Fault number 35150, fault value 0x80003f04 Incoming event ................................................................................ Event details: 384 of 507 : 15:23:53:544 16.09.96 Event ID: 16# F360:2422 Additional information 4 / 5: 16# 00 00 Additional information 1 / 2 / 3: 16# 894E 8000 3F04 Fault DO 8: Fault number 35150, fault value 0x80003f04 Incoming event ................................................................................ Event details: 385 of 507 : 15:23:47:626 16.09.96 Event ID: 16# F360:2422 Additional information 4 / 5: 16# 00 00 Additional information 1 / 2 / 3: 16# 894E 8000 3F04 Fault DO 8: Fault number 35150, fault value 0x80003f04 Incoming event ................................................................................ Event details: 386 of 507 : 15:23:47:554 16.09.96 Event ID: 16# F360:241E Additional information 4 / 5: 16# 00 00 Additional information 1 / 2 / 3: 16# 0640 0000 0000 Fault DO 4: Fault number 1600, fault value 0x0 Incoming event ................................................................................ Event details: 387 of 507 : 15:23:41:389 16.09.96 Event ID: 16# F360:240C Additional information 4 / 5: 16# 00 00 Additional information 1 / 2 / 3: 16# 0000 0000 0000 Ramp-up completed, cyclic operation Incoming event ................................................................................ Event details: 388 of 507 : 15:23:33:559 16.09.96 Event ID: 16# F360:240B Additional information 4 / 5: 16# 00 00 Additional information 1 / 2 / 3: 16# 029E 0000 0000 Ramp-up state r3988 = 670 reached Incoming event ................................................................................ Event details: 389 of 507 : 15:22:51:296 16.09.96 Event ID: 16# F360:240B Additional information 4 / 5: 16# 00 00 Additional information 1 / 2 / 3: 16# 02A8 0000 0000 Ramp-up state r3988 = 680 reached Incoming event ................................................................................ Event details: 390 of 507 : 15:22:51:280 16.09.96 Event ID: 16# F360:2414 Additional information 4 / 5: 16# 00 00 Additional information 1 / 2 / 3: 16# 0000 0000 0000 Ram2Rom of DO 0 performed Incoming event ................................................................................ Event details: 391 of 507 : 15:22:15:896 16.09.96 Event ID: 16# F360:2413 Additional information 4 / 5: 16# 00 00 Additional information 1 / 2 / 3: 16# 0000 0000 0000 Ram2Rom of DO 0 started Incoming event ................................................................................ Event details: 392 of 507 : 15:22:14:264 16.09.96 Event ID: 16# F360:2416 Additional information 4 / 5: 16# 00 00 Additional information 1 / 2 / 3: 16# 0000 0000 0000 Cyclic data exchange PZD IF1 started Incoming event ................................................................................ Event details: 393 of 507 : 15:22:14:240 16.09.96 Event ID: 16# F360:2418 Additional information 4 / 5: 16# 00 00 Additional information 1 / 2 / 3: 16# 0000 0000 0000 Cyclic data exchange PZD IF1 completed Incoming event ................................................................................ Event details: 394 of 507 : 15:22:13:429 16.09.96 Event ID: 16# F360:241D Additional information 4 / 5: 16# 00 00 Additional information 1 / 2 / 3: 16# 0672 0000 07D5 Fault DO 3: Fault number 1650, fault value 0x7d5 Incoming event ................................................................................ Event details: 395 of 507 : 15:22:13:365 16.09.96 Event ID: 16# F360:241E Additional information 4 / 5: 16# 00 00 Additional information 1 / 2 / 3: 16# 0672 0000 07D5 Fault DO 4: Fault number 1650, fault value 0x7d5 Incoming event ................................................................................ Event details: 396 of 507 : 15:22:13:293 16.09.96 Event ID: 16# F360:241F Additional information 4 / 5: 16# 00 00 Additional information 1 / 2 / 3: 16# 0672 0000 07D5 Fault DO 5: Fault number 1650, fault value 0x7d5 Incoming event ................................................................................ Event details: 397 of 507 : 15:22:13:213 16.09.96 Event ID: 16# F360:2420 Additional information 4 / 5: 16# 00 00 Additional information 1 / 2 / 3: 16# 0672 0000 07D5 Fault DO 6: Fault number 1650, fault value 0x7d5 Incoming event ................................................................................ Event details: 398 of 507 : 15:22:04:765 16.09.96 Event ID: 16# F360:2414 Additional information 4 / 5: 16# 00 00 Additional information 1 / 2 / 3: 16# 0000 0000 0000 Ram2Rom of DO 0 performed Incoming event ................................................................................ Event details: 399 of 507 : 15:21:38:909 16.09.96 Event ID: 16# F360:2413 Additional information 4 / 5: 16# 00 00 Additional information 1 / 2 / 3: 16# 0001 0000 0000 Ram2Rom of DO 1 started Incoming event ................................................................................ Event details: 400 of 507 : 15:21:22:997 16.09.96 Event ID: 16# F360:2400 Additional information 4 / 5: 16# 00 00 Additional information 1 / 2 / 3: 16# 0000 0000 0000 Power On Incoming event ................................................................................ Event details: 401 of 507 : 13:55:46:540 16.09.96 Event ID: 16# F360:2407 Additional information 4 / 5: 16# 00 00 Additional information 1 / 2 / 3: 16# 0000 0000 0000 Waiting for first commissioning (r3988 = 200) Incoming event ................................................................................ Event details: 402 of 507 : 13:55:45:996 16.09.96 Event ID: 16# F360:2400 Additional information 4 / 5: 16# 00 00 Additional information 1 / 2 / 3: 16# 0000 0000 0000 Power On Incoming event ................................................................................ Event details: 403 of 507 : 13:51:16:008 16.09.96 Event ID: 16# F360:2422 Additional information 4 / 5: 16# 00 00 Additional information 1 / 2 / 3: 16# 894E 8000 3F04 Fault DO 8: Fault number 35150, fault value 0x80003f04 Incoming event ................................................................................ Event details: 404 of 507 : 13:45:31:040 16.09.96 Event ID: 16# F360:2422 Additional information 4 / 5: 16# 00 00 Additional information 1 / 2 / 3: 16# 894E 8000 3F04 Fault DO 8: Fault number 35150, fault value 0x80003f04 Incoming event ................................................................................ Event details: 405 of 507 : 13:45:30:936 16.09.96 Event ID: 16# F360:241E Additional information 4 / 5: 16# 00 00 Additional information 1 / 2 / 3: 16# 0640 0000 0000 Fault DO 4: Fault number 1600, fault value 0x0 Incoming event ................................................................................ Event details: 406 of 507 : 22:02:09:318 03.01.92 Event ID: 16# F360:B306 Additional information 4 / 5: 16# 00 50 Additional information 1 / 2 / 3: 16# 000F 0000 0000 >>>>>>>>>>>> CX32: Start of diagnostic buffer, station address = 15 >>>>>>>>>>>> Incoming event ................................................................................ Event details: 407 of 507 : 02:33:46:255 19.09.96 Event ID: 16# F360:240C Additional information 4 / 5: 16# 00 00 Additional information 1 / 2 / 3: 16# 0000 0000 0000 Ramp-up completed, cyclic operation Incoming event ................................................................................ Event details: 408 of 507 : 02:33:43:928 19.09.96 Event ID: 16# F360:2416 Additional information 4 / 5: 16# 00 00 Additional information 1 / 2 / 3: 16# 0000 0000 0000 Cyclic data exchange PZD IF1 started Incoming event ................................................................................ Event details: 409 of 507 : 02:33:38:096 19.09.96 Event ID: 16# F360:240B Additional information 4 / 5: 16# 00 00 Additional information 1 / 2 / 3: 16# 029E 0000 0000 Ramp-up state r3988 = 670 reached Incoming event ................................................................................ Event details: 410 of 507 : 02:33:35:709 19.09.96 Event ID: 16# F360:2418 Additional information 4 / 5: 16# 00 00 Additional information 1 / 2 / 3: 16# 0000 0000 0000 Cyclic data exchange PZD IF1 completed Incoming event ................................................................................ Event details: 411 of 507 : 02:33:23:276 19.09.96 Event ID: 16# F360:2400 Additional information 4 / 5: 16# 00 00 Additional information 1 / 2 / 3: 16# 0000 0000 0000 Power On Incoming event ................................................................................ Event details: 412 of 507 : 02:29:08:583 19.09.96 Event ID: 16# F360:2421 Additional information 4 / 5: 16# 00 00 Additional information 1 / 2 / 3: 16# 0776 0000 0000 Fault DO 7: Fault number 1910, fault value 0x0 Incoming event ................................................................................ Event details: 413 of 507 : 02:29:08:503 19.09.96 Event ID: 16# F360:241B Additional information 4 / 5: 16# 00 00 Additional information 1 / 2 / 3: 16# 077B 0000 0000 Fault DO 1: Fault number 1915, fault value 0x0 Incoming event ................................................................................ Event details: 414 of 507 : 02:29:08:423 19.09.96 Event ID: 16# F360:241C Additional information 4 / 5: 16# 00 00 Additional information 1 / 2 / 3: 16# 0776 0000 0000 Fault DO 2: Fault number 1910, fault value 0x0 Incoming event ................................................................................ Event details: 415 of 507 : 02:29:08:351 19.09.96 Event ID: 16# F360:241C Additional information 4 / 5: 16# 00 00 Additional information 1 / 2 / 3: 16# 0778 0000 0000 Fault DO 2: Fault number 1912, fault value 0x0 Incoming event ................................................................................ Event details: 416 of 507 : 02:29:08:279 19.09.96 Event ID: 16# F360:241C Additional information 4 / 5: 16# 00 00 Additional information 1 / 2 / 3: 16# 077B 0000 0000 Fault DO 2: Fault number 1915, fault value 0x0 Incoming event ................................................................................ Event details: 417 of 507 : 02:29:08:191 19.09.96 Event ID: 16# F360:241D Additional information 4 / 5: 16# 00 00 Additional information 1 / 2 / 3: 16# 0776 0000 0000 Fault DO 3: Fault number 1910, fault value 0x0 Incoming event ................................................................................ Event details: 418 of 507 : 02:29:08:111 19.09.96 Event ID: 16# F360:241D Additional information 4 / 5: 16# 00 00 Additional information 1 / 2 / 3: 16# 0778 0000 0000 Fault DO 3: Fault number 1912, fault value 0x0 Incoming event ................................................................................ Event details: 419 of 507 : 02:29:08:039 19.09.96 Event ID: 16# F360:241E Additional information 4 / 5: 16# 00 00 Additional information 1 / 2 / 3: 16# 0776 0000 0000 Fault DO 4: Fault number 1910, fault value 0x0 Incoming event ................................................................................ Event details: 420 of 507 : 02:29:07:959 19.09.96 Event ID: 16# F360:241E Additional information 4 / 5: 16# 00 00 Additional information 1 / 2 / 3: 16# 0778 0000 0000 Fault DO 4: Fault number 1912, fault value 0x0 Incoming event ................................................................................ Event details: 421 of 507 : 02:29:07:887 19.09.96 Event ID: 16# F360:241F Additional information 4 / 5: 16# 00 00 Additional information 1 / 2 / 3: 16# 0776 0000 0000 Fault DO 5: Fault number 1910, fault value 0x0 Incoming event ................................................................................ Event details: 422 of 507 : 02:29:07:815 19.09.96 Event ID: 16# F360:241F Additional information 4 / 5: 16# 00 00 Additional information 1 / 2 / 3: 16# 0778 0000 0000 Fault DO 5: Fault number 1912, fault value 0x0 Incoming event ................................................................................ Event details: 423 of 507 : 02:29:07:735 19.09.96 Event ID: 16# F360:2420 Additional information 4 / 5: 16# 00 00 Additional information 1 / 2 / 3: 16# 0776 0000 0000 Fault DO 6: Fault number 1910, fault value 0x0 Incoming event ................................................................................ Event details: 424 of 507 : 02:29:07:655 19.09.96 Event ID: 16# F360:2420 Additional information 4 / 5: 16# 00 00 Additional information 1 / 2 / 3: 16# 0778 0000 0000 Fault DO 6: Fault number 1912, fault value 0x0 Incoming event ................................................................................ Event details: 425 of 507 : 02:29:07:583 19.09.96 Event ID: 16# F360:2421 Additional information 4 / 5: 16# 00 00 Additional information 1 / 2 / 3: 16# 0778 0000 0000 Fault DO 7: Fault number 1912, fault value 0x0 Incoming event ................................................................................ Event details: 426 of 507 : 02:16:27:501 19.09.96 Event ID: 16# F360:241B Additional information 4 / 5: 16# 00 00 Additional information 1 / 2 / 3: 16# 077B 0000 0000 Fault DO 1: Fault number 1915, fault value 0x0 Incoming event ................................................................................ Event details: 427 of 507 : 02:16:27:389 19.09.96 Event ID: 16# F360:241C Additional information 4 / 5: 16# 00 00 Additional information 1 / 2 / 3: 16# 0776 0000 0000 Fault DO 2: Fault number 1910, fault value 0x0 Incoming event ................................................................................ Event details: 428 of 507 : 02:16:27:317 19.09.96 Event ID: 16# F360:241C Additional information 4 / 5: 16# 00 00 Additional information 1 / 2 / 3: 16# 0778 0000 0000 Fault DO 2: Fault number 1912, fault value 0x0 Incoming event ................................................................................ Event details: 429 of 507 : 02:16:27:237 19.09.96 Event ID: 16# F360:241C Additional information 4 / 5: 16# 00 00 Additional information 1 / 2 / 3: 16# 077B 0000 0000 Fault DO 2: Fault number 1915, fault value 0x0 Incoming event ................................................................................ Event details: 430 of 507 : 02:16:27:157 19.09.96 Event ID: 16# F360:241D Additional information 4 / 5: 16# 00 00 Additional information 1 / 2 / 3: 16# 0776 0000 0000 Fault DO 3: Fault number 1910, fault value 0x0 Incoming event ................................................................................ Event details: 431 of 507 : 02:16:27:061 19.09.96 Event ID: 16# F360:241D Additional information 4 / 5: 16# 00 00 Additional information 1 / 2 / 3: 16# 0778 0000 0000 Fault DO 3: Fault number 1912, fault value 0x0 Incoming event ................................................................................ Event details: 432 of 507 : 02:16:26:957 19.09.96 Event ID: 16# F360:241E Additional information 4 / 5: 16# 00 00 Additional information 1 / 2 / 3: 16# 0776 0000 0000 Fault DO 4: Fault number 1910, fault value 0x0 Incoming event ................................................................................ Event details: 433 of 507 : 02:16:26:877 19.09.96 Event ID: 16# F360:241E Additional information 4 / 5: 16# 00 00 Additional information 1 / 2 / 3: 16# 0778 0000 0000 Fault DO 4: Fault number 1912, fault value 0x0 Incoming event ................................................................................ Event details: 434 of 507 : 02:16:26:773 19.09.96 Event ID: 16# F360:241F Additional information 4 / 5: 16# 00 00 Additional information 1 / 2 / 3: 16# 0776 0000 0000 Fault DO 5: Fault number 1910, fault value 0x0 Incoming event ................................................................................ Event details: 435 of 507 : 02:16:26:693 19.09.96 Event ID: 16# F360:241F Additional information 4 / 5: 16# 00 00 Additional information 1 / 2 / 3: 16# 0778 0000 0000 Fault DO 5: Fault number 1912, fault value 0x0 Incoming event ................................................................................ Event details: 436 of 507 : 02:16:26:621 19.09.96 Event ID: 16# F360:2420 Additional information 4 / 5: 16# 00 00 Additional information 1 / 2 / 3: 16# 0776 0000 0000 Fault DO 6: Fault number 1910, fault value 0x0 Incoming event ................................................................................ Event details: 437 of 507 : 02:16:26:549 19.09.96 Event ID: 16# F360:2420 Additional information 4 / 5: 16# 00 00 Additional information 1 / 2 / 3: 16# 0778 0000 0000 Fault DO 6: Fault number 1912, fault value 0x0 Incoming event ................................................................................ Event details: 438 of 507 : 02:16:26:461 19.09.96 Event ID: 16# F360:2421 Additional information 4 / 5: 16# 00 00 Additional information 1 / 2 / 3: 16# 0776 0000 0000 Fault DO 7: Fault number 1910, fault value 0x0 Incoming event ................................................................................ Event details: 439 of 507 : 02:16:26:390 19.09.96 Event ID: 16# F360:2421 Additional information 4 / 5: 16# 00 00 Additional information 1 / 2 / 3: 16# 0778 0000 0000 Fault DO 7: Fault number 1912, fault value 0x0 Incoming event ................................................................................ Event details: 440 of 507 : 02:14:50:442 19.09.96 Event ID: 16# F360:240C Additional information 4 / 5: 16# 00 00 Additional information 1 / 2 / 3: 16# 0000 0000 0000 Ramp-up completed, cyclic operation Incoming event ................................................................................ Event details: 441 of 507 : 02:14:48:246 19.09.96 Event ID: 16# F360:2416 Additional information 4 / 5: 16# 00 00 Additional information 1 / 2 / 3: 16# 0000 0000 0000 Cyclic data exchange PZD IF1 started Incoming event ................................................................................ Event details: 442 of 507 : 02:14:41:654 19.09.96 Event ID: 16# F360:240B Additional information 4 / 5: 16# 00 00 Additional information 1 / 2 / 3: 16# 029E 0000 0000 Ramp-up state r3988 = 670 reached Incoming event ................................................................................ Event details: 443 of 507 : 02:14:39:098 19.09.96 Event ID: 16# F360:2418 Additional information 4 / 5: 16# 00 00 Additional information 1 / 2 / 3: 16# 0000 0000 0000 Cyclic data exchange PZD IF1 completed Incoming event ................................................................................ Event details: 444 of 507 : 02:14:27:295 19.09.96 Event ID: 16# F360:2400 Additional information 4 / 5: 16# 00 00 Additional information 1 / 2 / 3: 16# 0000 0000 0000 Power On Incoming event ................................................................................ Event details: 445 of 507 : 02:14:25:711 19.09.96 Event ID: 16# F360:2421 Additional information 4 / 5: 16# 00 00 Additional information 1 / 2 / 3: 16# 0659 0000 0001 Fault DO 7: Fault number 1625, fault value 0x1 Incoming event ................................................................................ Event details: 446 of 507 : 01:57:04:564 19.09.96 Event ID: 16# F360:240C Additional information 4 / 5: 16# 00 00 Additional information 1 / 2 / 3: 16# 0000 0000 0000 Ramp-up completed, cyclic operation Incoming event ................................................................................ Event details: 447 of 507 : 01:57:02:169 19.09.96 Event ID: 16# F360:2416 Additional information 4 / 5: 16# 00 00 Additional information 1 / 2 / 3: 16# 0000 0000 0000 Cyclic data exchange PZD IF1 started Incoming event ................................................................................ Event details: 448 of 507 : 01:56:56:065 19.09.96 Event ID: 16# F360:240B Additional information 4 / 5: 16# 00 00 Additional information 1 / 2 / 3: 16# 029E 0000 0000 Ramp-up state r3988 = 670 reached Incoming event ................................................................................ Event details: 449 of 507 : 01:56:53:324 19.09.96 Event ID: 16# F360:2418 Additional information 4 / 5: 16# 00 00 Additional information 1 / 2 / 3: 16# 0000 0000 0000 Cyclic data exchange PZD IF1 completed Incoming event ................................................................................ Event details: 450 of 507 : 01:56:41:246 19.09.96 Event ID: 16# F360:2400 Additional information 4 / 5: 16# 00 00 Additional information 1 / 2 / 3: 16# 0000 0000 0000 Power On Incoming event ................................................................................ Event details: 451 of 507 : 01:56:39:903 19.09.96 Event ID: 16# F360:2421 Additional information 4 / 5: 16# 00 00 Additional information 1 / 2 / 3: 16# 0659 0000 0001 Fault DO 7: Fault number 1625, fault value 0x1 Incoming event ................................................................................ Event details: 452 of 507 : 01:46:36:479 19.09.96 Event ID: 16# F360:240C Additional information 4 / 5: 16# 00 00 Additional information 1 / 2 / 3: 16# 0000 0000 0000 Ramp-up completed, cyclic operation Incoming event ................................................................................ Event details: 453 of 507 : 01:46:34:004 19.09.96 Event ID: 16# F360:2416 Additional information 4 / 5: 16# 00 00 Additional information 1 / 2 / 3: 16# 0000 0000 0000 Cyclic data exchange PZD IF1 started Incoming event ................................................................................ Event details: 454 of 507 : 01:46:28:236 19.09.96 Event ID: 16# F360:240B Additional information 4 / 5: 16# 00 00 Additional information 1 / 2 / 3: 16# 029E 0000 0000 Ramp-up state r3988 = 670 reached Incoming event ................................................................................ Event details: 455 of 507 : 01:46:26:196 19.09.96 Event ID: 16# F360:2418 Additional information 4 / 5: 16# 00 00 Additional information 1 / 2 / 3: 16# 0000 0000 0000 Cyclic data exchange PZD IF1 completed Incoming event ................................................................................ Event details: 456 of 507 : 01:46:13:191 19.09.96 Event ID: 16# F360:2400 Additional information 4 / 5: 16# 00 00 Additional information 1 / 2 / 3: 16# 0000 0000 0000 Power On Incoming event ................................................................................ Event details: 457 of 507 : 01:46:11:036 19.09.96 Event ID: 16# F360:2421 Additional information 4 / 5: 16# 00 00 Additional information 1 / 2 / 3: 16# 0659 0000 0001 Fault DO 7: Fault number 1625, fault value 0x1 Incoming event ................................................................................ Event details: 458 of 507 : 01:39:44:558 19.09.96 Event ID: 16# F360:240C Additional information 4 / 5: 16# 00 00 Additional information 1 / 2 / 3: 16# 0000 0000 0000 Ramp-up completed, cyclic operation Incoming event ................................................................................ Event details: 459 of 507 : 01:39:42:310 19.09.96 Event ID: 16# F360:2416 Additional information 4 / 5: 16# 00 00 Additional information 1 / 2 / 3: 16# 0000 0000 0000 Cyclic data exchange PZD IF1 started Incoming event ................................................................................ Event details: 460 of 507 : 01:39:36:382 19.09.96 Event ID: 16# F360:240B Additional information 4 / 5: 16# 00 00 Additional information 1 / 2 / 3: 16# 029E 0000 0000 Ramp-up state r3988 = 670 reached Incoming event ................................................................................ Event details: 461 of 507 : 01:39:35:873 19.09.96 Event ID: 16# F360:2414 Additional information 4 / 5: 16# 00 00 Additional information 1 / 2 / 3: 16# 0000 0000 0000 Ram2Rom of DO 0 performed Incoming event ................................................................................ Event details: 462 of 507 : 01:38:58:825 19.09.96 Event ID: 16# F360:2413 Additional information 4 / 5: 16# 00 00 Additional information 1 / 2 / 3: 16# 0000 0000 0000 Ram2Rom of DO 0 started Incoming event ................................................................................ Event details: 463 of 507 : 01:38:56:969 19.09.96 Event ID: 16# F360:2418 Additional information 4 / 5: 16# 00 00 Additional information 1 / 2 / 3: 16# 0000 0000 0000 Cyclic data exchange PZD IF1 completed Incoming event ................................................................................ Event details: 464 of 507 : 01:38:14:634 19.09.96 Event ID: 16# F360:2400 Additional information 4 / 5: 16# 00 00 Additional information 1 / 2 / 3: 16# 0000 0000 0000 Power On Incoming event ................................................................................ Event details: 465 of 507 : 01:02:59:654 19.09.96 Event ID: 16# F360:2421 Additional information 4 / 5: 16# 00 00 Additional information 1 / 2 / 3: 16# 0776 0000 0000 Fault DO 7: Fault number 1910, fault value 0x0 Incoming event ................................................................................ Event details: 466 of 507 : 01:02:59:565 19.09.96 Event ID: 16# F360:241B Additional information 4 / 5: 16# 00 00 Additional information 1 / 2 / 3: 16# 077B 0000 0000 Fault DO 1: Fault number 1915, fault value 0x0 Incoming event ................................................................................ Event details: 467 of 507 : 01:02:59:493 19.09.96 Event ID: 16# F360:241C Additional information 4 / 5: 16# 00 00 Additional information 1 / 2 / 3: 16# 0776 0000 0000 Fault DO 2: Fault number 1910, fault value 0x0 Incoming event ................................................................................ Event details: 468 of 507 : 01:02:59:413 19.09.96 Event ID: 16# F360:241C Additional information 4 / 5: 16# 00 00 Additional information 1 / 2 / 3: 16# 0778 0000 0000 Fault DO 2: Fault number 1912, fault value 0x0 Incoming event ................................................................................ Event details: 469 of 507 : 01:02:59:341 19.09.96 Event ID: 16# F360:241C Additional information 4 / 5: 16# 00 00 Additional information 1 / 2 / 3: 16# 077B 0000 0000 Fault DO 2: Fault number 1915, fault value 0x0 Incoming event ................................................................................ Event details: 470 of 507 : 01:02:59:269 19.09.96 Event ID: 16# F360:241D Additional information 4 / 5: 16# 00 00 Additional information 1 / 2 / 3: 16# 0776 0000 0000 Fault DO 3: Fault number 1910, fault value 0x0 Incoming event ................................................................................ Event details: 471 of 507 : 01:02:59:189 19.09.96 Event ID: 16# F360:241D Additional information 4 / 5: 16# 00 00 Additional information 1 / 2 / 3: 16# 0778 0000 0000 Fault DO 3: Fault number 1912, fault value 0x0 Incoming event ................................................................................ Event details: 472 of 507 : 01:02:59:109 19.09.96 Event ID: 16# F360:241E Additional information 4 / 5: 16# 00 00 Additional information 1 / 2 / 3: 16# 0776 0000 0000 Fault DO 4: Fault number 1910, fault value 0x0 Incoming event ................................................................................ Event details: 473 of 507 : 01:02:59:037 19.09.96 Event ID: 16# F360:241E Additional information 4 / 5: 16# 00 00 Additional information 1 / 2 / 3: 16# 0778 0000 0000 Fault DO 4: Fault number 1912, fault value 0x0 Incoming event ................................................................................ Event details: 474 of 507 : 01:02:58:949 19.09.96 Event ID: 16# F360:241F Additional information 4 / 5: 16# 00 00 Additional information 1 / 2 / 3: 16# 0776 0000 0000 Fault DO 5: Fault number 1910, fault value 0x0 Incoming event ................................................................................ Event details: 475 of 507 : 01:02:58:877 19.09.96 Event ID: 16# F360:241F Additional information 4 / 5: 16# 00 00 Additional information 1 / 2 / 3: 16# 0778 0000 0000 Fault DO 5: Fault number 1912, fault value 0x0 Incoming event ................................................................................ Event details: 476 of 507 : 01:02:58:805 19.09.96 Event ID: 16# F360:2420 Additional information 4 / 5: 16# 00 00 Additional information 1 / 2 / 3: 16# 0776 0000 0000 Fault DO 6: Fault number 1910, fault value 0x0 Incoming event ................................................................................ Event details: 477 of 507 : 01:02:58:725 19.09.96 Event ID: 16# F360:2420 Additional information 4 / 5: 16# 00 00 Additional information 1 / 2 / 3: 16# 0778 0000 0000 Fault DO 6: Fault number 1912, fault value 0x0 Incoming event ................................................................................ Event details: 478 of 507 : 01:02:58:646 19.09.96 Event ID: 16# F360:2421 Additional information 4 / 5: 16# 00 00 Additional information 1 / 2 / 3: 16# 0778 0000 0000 Fault DO 7: Fault number 1912, fault value 0x0 Incoming event ................................................................................ Event details: 479 of 507 : 01:02:57:821 19.09.96 Event ID: 16# F360:2421 Additional information 4 / 5: 16# 00 00 Additional information 1 / 2 / 3: 16# 0776 0000 0000 Fault DO 7: Fault number 1910, fault value 0x0 Incoming event ................................................................................ Event details: 480 of 507 : 01:02:57:589 19.09.96 Event ID: 16# F360:241B Additional information 4 / 5: 16# 00 00 Additional information 1 / 2 / 3: 16# 077B 0000 0000 Fault DO 1: Fault number 1915, fault value 0x0 Incoming event ................................................................................ Event details: 481 of 507 : 01:02:57:509 19.09.96 Event ID: 16# F360:241C Additional information 4 / 5: 16# 00 00 Additional information 1 / 2 / 3: 16# 0776 0000 0000 Fault DO 2: Fault number 1910, fault value 0x0 Incoming event ................................................................................ Event details: 482 of 507 : 01:02:57:429 19.09.96 Event ID: 16# F360:241C Additional information 4 / 5: 16# 00 00 Additional information 1 / 2 / 3: 16# 0778 0000 0000 Fault DO 2: Fault number 1912, fault value 0x0 Incoming event ................................................................................ Event details: 483 of 507 : 01:02:57:357 19.09.96 Event ID: 16# F360:241C Additional information 4 / 5: 16# 00 00 Additional information 1 / 2 / 3: 16# 077B 0000 0000 Fault DO 2: Fault number 1915, fault value 0x0 Incoming event ................................................................................ Event details: 484 of 507 : 01:02:57:285 19.09.96 Event ID: 16# F360:241D Additional information 4 / 5: 16# 00 00 Additional information 1 / 2 / 3: 16# 0776 0000 0000 Fault DO 3: Fault number 1910, fault value 0x0 Incoming event ................................................................................ Event details: 485 of 507 : 01:02:57:205 19.09.96 Event ID: 16# F360:241D Additional information 4 / 5: 16# 00 00 Additional information 1 / 2 / 3: 16# 0778 0000 0000 Fault DO 3: Fault number 1912, fault value 0x0 Incoming event ................................................................................ Event details: 486 of 507 : 01:02:57:125 19.09.96 Event ID: 16# F360:241E Additional information 4 / 5: 16# 00 00 Additional information 1 / 2 / 3: 16# 0776 0000 0000 Fault DO 4: Fault number 1910, fault value 0x0 Incoming event ................................................................................ Event details: 487 of 507 : 01:02:57:053 19.09.96 Event ID: 16# F360:241E Additional information 4 / 5: 16# 00 00 Additional information 1 / 2 / 3: 16# 0778 0000 0000 Fault DO 4: Fault number 1912, fault value 0x0 Incoming event ................................................................................ Event details: 488 of 507 : 01:02:56:973 19.09.96 Event ID: 16# F360:241F Additional information 4 / 5: 16# 00 00 Additional information 1 / 2 / 3: 16# 0776 0000 0000 Fault DO 5: Fault number 1910, fault value 0x0 Incoming event ................................................................................ Event details: 489 of 507 : 01:02:56:901 19.09.96 Event ID: 16# F360:241F Additional information 4 / 5: 16# 00 00 Additional information 1 / 2 / 3: 16# 0778 0000 0000 Fault DO 5: Fault number 1912, fault value 0x0 Incoming event ................................................................................ Event details: 490 of 507 : 01:02:56:829 19.09.96 Event ID: 16# F360:2420 Additional information 4 / 5: 16# 00 00 Additional information 1 / 2 / 3: 16# 0776 0000 0000 Fault DO 6: Fault number 1910, fault value 0x0 Incoming event ................................................................................ Event details: 491 of 507 : 01:02:56:749 19.09.96 Event ID: 16# F360:2420 Additional information 4 / 5: 16# 00 00 Additional information 1 / 2 / 3: 16# 0778 0000 0000 Fault DO 6: Fault number 1912, fault value 0x0 Incoming event ................................................................................ Event details: 492 of 507 : 01:02:56:669 19.09.96 Event ID: 16# F360:2421 Additional information 4 / 5: 16# 00 00 Additional information 1 / 2 / 3: 16# 0778 0000 0000 Fault DO 7: Fault number 1912, fault value 0x0 Incoming event ................................................................................ Event details: 493 of 507 : 01:02:55:621 19.09.96 Event ID: 16# F360:241F Additional information 4 / 5: 16# 00 00 Additional information 1 / 2 / 3: 16# 0776 0000 0000 Fault DO 5: Fault number 1910, fault value 0x0 Incoming event ................................................................................ Event details: 494 of 507 : 01:02:55:541 19.09.96 Event ID: 16# F360:241F Additional information 4 / 5: 16# 00 00 Additional information 1 / 2 / 3: 16# 0778 0000 0000 Fault DO 5: Fault number 1912, fault value 0x0 Incoming event ................................................................................ Event details: 495 of 507 : 01:02:55:453 19.09.96 Event ID: 16# F360:2420 Additional information 4 / 5: 16# 00 00 Additional information 1 / 2 / 3: 16# 0776 0000 0000 Fault DO 6: Fault number 1910, fault value 0x0 Incoming event ................................................................................ Event details: 496 of 507 : 01:02:55:373 19.09.96 Event ID: 16# F360:2420 Additional information 4 / 5: 16# 00 00 Additional information 1 / 2 / 3: 16# 0778 0000 0000 Fault DO 6: Fault number 1912, fault value 0x0 Incoming event ................................................................................ Event details: 497 of 507 : 01:02:55:293 19.09.96 Event ID: 16# F360:2421 Additional information 4 / 5: 16# 00 00 Additional information 1 / 2 / 3: 16# 0776 0000 0000 Fault DO 7: Fault number 1910, fault value 0x0 Incoming event ................................................................................ Event details: 498 of 507 : 01:02:55:189 19.09.96 Event ID: 16# F360:2421 Additional information 4 / 5: 16# 00 00 Additional information 1 / 2 / 3: 16# 0778 0000 0000 Fault DO 7: Fault number 1912, fault value 0x0 Incoming event ................................................................................ Event details: 499 of 507 : 01:02:55:109 19.09.96 Event ID: 16# F360:241B Additional information 4 / 5: 16# 00 00 Additional information 1 / 2 / 3: 16# 077B 0000 0000 Fault DO 1: Fault number 1915, fault value 0x0 Incoming event ................................................................................ Event details: 500 of 507 : 01:02:55:013 19.09.96 Event ID: 16# F360:241C Additional information 4 / 5: 16# 00 00 Additional information 1 / 2 / 3: 16# 0776 0000 0000 Fault DO 2: Fault number 1910, fault value 0x0 Incoming event ................................................................................ Event details: 501 of 507 : 01:02:54:917 19.09.96 Event ID: 16# F360:241C Additional information 4 / 5: 16# 00 00 Additional information 1 / 2 / 3: 16# 0778 0000 0000 Fault DO 2: Fault number 1912, fault value 0x0 Incoming event ................................................................................ Event details: 502 of 507 : 01:02:54:845 19.09.96 Event ID: 16# F360:241C Additional information 4 / 5: 16# 00 00 Additional information 1 / 2 / 3: 16# 077B 0000 0000 Fault DO 2: Fault number 1915, fault value 0x0 Incoming event ................................................................................ Event details: 503 of 507 : 01:02:54:765 19.09.96 Event ID: 16# F360:241D Additional information 4 / 5: 16# 00 00 Additional information 1 / 2 / 3: 16# 0776 0000 0000 Fault DO 3: Fault number 1910, fault value 0x0 Incoming event ................................................................................ Event details: 504 of 507 : 01:02:54:685 19.09.96 Event ID: 16# F360:241D Additional information 4 / 5: 16# 00 00 Additional information 1 / 2 / 3: 16# 0778 0000 0000 Fault DO 3: Fault number 1912, fault value 0x0 Incoming event ................................................................................ Event details: 505 of 507 : 01:02:54:613 19.09.96 Event ID: 16# F360:241E Additional information 4 / 5: 16# 00 00 Additional information 1 / 2 / 3: 16# 0776 0000 0000 Fault DO 4: Fault number 1910, fault value 0x0 Incoming event ................................................................................ Event details: 506 of 507 : 01:02:54:525 19.09.96 Event ID: 16# F360:241E Additional information 4 / 5: 16# 00 00 Additional information 1 / 2 / 3: 16# 0778 0000 0000 Fault DO 4: Fault number 1912, fault value 0x0 Incoming event ................................................................................ Event details: 507 of 507 : 00:54:49:240 19.09.96 Event ID: 16# F360:240C Additional information 4 / 5: 16# 00 00 Additional information 1 / 2 / 3: 16# 0000 0000 0000 Ramp-up completed, cyclic operation Incoming event ................................................................................ -------------------------------------------------------------------------------- -------------------------------------------------------------------------------- ------------------------------------------------------------------------------------- - Task manager - ------------------------------------------------------------------------------------- Task Task status Current min max Mean value ------------------------------------------------------------------------------------- BackgroundTask STOPPED 0.000 ms 0.000 ms 0.000 ms 0.000 ms ControlPanelTask STOPPED 0.000 ms 0.000 ms 0.000 ms 0.000 ms ExecutionFaultTask STOPPED 0.000 ms 0.000 ms 0.000 ms 0.000 ms IPOsynchronousTask STOPPED 0.000 ms 0.000 ms 0.000 ms 0.000 ms MotionTask_1 STOPPED 0.000 ms 0.000 ms 0.000 ms 0.000 ms MotionTask_2 STOPPED 0.000 ms 0.000 ms 0.000 ms 0.000 ms MotionTask_3 STOPPED 0.000 ms 0.000 ms 0.000 ms 0.000 ms MotionTask_10 STOPPED 0.000 ms 0.000 ms 0.000 ms 0.000 ms MotionTask_11 STOPPED 0.000 ms 0.000 ms 0.000 ms 0.000 ms MotionTask_12 STOPPED 0.000 ms 0.000 ms 0.000 ms 0.000 ms MotionTask_13 STOPPED 0.000 ms 0.000 ms 0.000 ms 0.000 ms MotionTask_14 STOPPED 0.000 ms 0.000 ms 0.000 ms 0.000 ms MotionTask_15 STOPPED 0.000 ms 0.000 ms 0.000 ms 0.000 ms MotionTask_16 STOPPED 0.000 ms 0.000 ms 0.000 ms 0.000 ms MotionTask_17 STOPPED 0.000 ms 0.000 ms 0.000 ms 0.000 ms MotionTask_18 STOPPED 0.000 ms 0.000 ms 0.000 ms 0.000 ms MotionTask_19 STOPPED 0.000 ms 0.000 ms 0.000 ms 0.000 ms MotionTask_23 STOPPED 0.000 ms 0.000 ms 0.000 ms 0.000 ms PeripheralFaultTask STOPPED 0.000 ms 0.000 ms 0.000 ms 0.000 ms ServoSynchronousTask STOPPED 0.000 ms 0.000 ms 0.000 ms 0.000 ms ShutdownTask STOPPED 1001.920 ms 1001.920 ms 1001.920 ms 1001.920 ms StartupTask STOPPED 0.436 ms 0.436 ms 0.436 ms 0.436 ms TechnologicalFaultTask STOPPED 0.000 ms 0.000 ms 0.000 ms 0.000 ms TimeFaultBackgroundTask STOPPED 0.000 ms 0.000 ms 0.000 ms 0.000 ms TimeFaultTask STOPPED 0.000 ms 0.000 ms 0.000 ms 0.000 ms of a system task STOPPED 0.000 ms 0.000 ms 0.000 ms 0.000 ms of a system task STOPPED 0.000 ms 0.000 ms 0.000 ms 0.000 ms ------------------------------------------------------------------------------------- ------------------------------------------------------------------------------------- -------------------------------------------------------------------------------- - System utilization - -------------------------------------------------------------------------------- RAM disk........ 0.8 % RAM............. 38.0 % ROM............. 6.1 % Retentive data.. 22.3 % CPU utilization: 16 % min...... 2.00 ms Current.. 2.00 ms max...... 2.00 ms I/O controller..... 77 % Round robin........ 0 % Communication...... 1 % I/O copying time... 0 % I/O cycle time..... 0 % -------------------------------------------------------------------------------- -------------------------------------------------------------------------------- -------------------------------------------------------------------------------- - Userlog - -------------------------------------------------------------------------------- -------------------------------------------------------------------------------- -------------------------------------------------------------------------------- -------------------------------------------------------------------------------- - Syslog - -------------------------------------------------------------------------------- 04/08/2013 08:04:54.000 HINT: File system successfully mounted 04/08/2013 08:04:54.000 HINT: Starting control 04/08/2013 08:22:55.000 HINT: File system successfully mounted 04/08/2013 08:22:55.000 HINT: Starting control 04/08/2013 08:25:50.000 HINT: File system successfully mounted 04/08/2013 08:25:50.000 HINT: Starting control 04/09/2013 02:00:51.000 HINT: File system successfully mounted 04/09/2013 02:00:51.000 HINT: Starting control 04/11/2013 02:46:08.000 HINT: File system successfully mounted 04/11/2013 02:46:08.000 HINT: Starting control 04/19/2013 07:31:57.000 HINT: File system successfully mounted 04/19/2013 07:31:57.000 HINT: Starting control 04/24/2013 00:40:39.000 HINT: File system successfully mounted 04/24/2013 00:40:39.000 HINT: Starting control 05/13/2013 01:02:27.000 HINT: File system successfully mounted 05/13/2013 01:02:27.000 HINT: Starting control 05/22/2013 15:16:36.000 HINT: File system successfully mounted 05/22/2013 15:16:36.000 HINT: Starting control 05/22/2013 15:32:07.000 HINT: File system successfully mounted 05/22/2013 15:32:07.000 HINT: Starting control 06/05/2013 09:05:53.000 HINT: File system successfully mounted 06/05/2013 09:05:53.000 HINT: Starting control 06/08/2013 04:30:56.000 HINT: File system successfully mounted 06/08/2013 04:30:56.000 HINT: Starting control 06/17/2013 12:02:44.000 HINT: File system successfully mounted 06/17/2013 12:02:44.000 HINT: Starting control 06/17/2013 12:05:45.000 HINT: File system successfully mounted 06/17/2013 12:05:45.000 HINT: Starting control 06/29/2013 21:57:45.000 HINT: File system successfully mounted 06/29/2013 21:57:45.000 HINT: Starting control 07/02/2013 21:32:51.000 HINT: File system successfully mounted 07/02/2013 21:32:51.000 HINT: Starting control 07/06/2013 23:58:05.000 HINT: File system successfully mounted 07/06/2013 23:58:05.000 HINT: Starting control 07/10/2013 14:00:31.000 HINT: File system successfully mounted 07/10/2013 14:00:31.000 HINT: Starting control 07/21/2013 08:58:30.000 HINT: File system successfully mounted 07/21/2013 08:58:30.000 HINT: Starting control 07/21/2013 11:36:11.000 HINT: File system successfully mounted 07/21/2013 11:36:11.000 HINT: Starting control 07/26/2013 03:31:32.000 HINT: File system successfully mounted 07/26/2013 03:31:32.000 HINT: Starting control 07/26/2013 14:11:39.000 HINT: File system successfully mounted 07/26/2013 14:11:39.000 HINT: Starting control 07/27/2013 01:21:42.000 HINT: File system successfully mounted 07/27/2013 01:21:42.000 HINT: Starting control 07/27/2013 01:29:43.000 HINT: File system successfully mounted 07/27/2013 01:29:43.000 HINT: Starting control 07/28/2013 14:37:16.000 HINT: File system successfully mounted 07/28/2013 14:37:16.000 HINT: Starting control 07/29/2013 12:05:49.000 HINT: File system successfully mounted 07/29/2013 12:05:49.000 HINT: Starting control 07/31/2013 02:11:33.000 HINT: File system successfully mounted 07/31/2013 02:11:33.000 HINT: Starting control 08/01/2013 12:52:52.000 HINT: File system successfully mounted 08/01/2013 12:52:52.000 HINT: Starting control 08/02/2013 12:53:53.000 HINT: File system successfully mounted 08/02/2013 12:53:53.000 HINT: Starting control 08/08/2013 13:14:23.000 HINT: File system successfully mounted 08/08/2013 13:14:23.000 HINT: Starting control 08/09/2013 03:48:17.000 HINT: File system successfully mounted 08/09/2013 03:48:17.000 HINT: Starting control 08/09/2013 08:52:42.000 HINT: File system successfully mounted 08/09/2013 08:52:42.000 HINT: Starting control 08/09/2013 09:48:50.000 HINT: File system successfully mounted 08/09/2013 09:48:50.000 HINT: Starting control 08/10/2013 12:48:57.000 HINT: File system successfully mounted 08/10/2013 12:48:57.000 HINT: Starting control 08/11/2013 05:34:27.000 HINT: File system successfully mounted 08/11/2013 05:34:27.000 HINT: Starting control 08/15/2013 02:44:55.000 HINT: File system successfully mounted 08/15/2013 02:44:55.000 HINT: Starting control 08/16/2013 11:19:12.000 HINT: File system successfully mounted 08/16/2013 11:19:12.000 HINT: Starting control 08/24/2013 10:53:15.000 HINT: File system successfully mounted 08/24/2013 10:53:15.000 HINT: Starting control 08/26/2013 04:18:35.000 HINT: File system successfully mounted 08/26/2013 04:18:35.000 HINT: Starting control 08/26/2013 09:40:02.000 HINT: File system successfully mounted 08/26/2013 09:40:02.000 HINT: Starting control 08/26/2013 10:41:01.000 HINT: File system successfully mounted 08/26/2013 10:41:01.000 HINT: Starting control 09/08/2013 05:08:58.000 HINT: File system successfully mounted 09/08/2013 05:08:58.000 HINT: Starting control 09/13/2013 15:15:28.000 HINT: File system successfully mounted 09/13/2013 15:15:28.000 HINT: Starting control 09/13/2013 15:23:23.000 HINT: File system successfully mounted 09/13/2013 15:23:23.000 HINT: Starting control 09/13/2013 15:33:50.000 HINT: File system successfully mounted 09/13/2013 15:33:50.000 HINT: Starting control 09/13/2013 15:50:29.000 HINT: File system successfully mounted 09/13/2013 15:50:29.000 HINT: Starting control 09/13/2013 16:08:28.000 HINT: File system successfully mounted 09/13/2013 16:08:28.000 HINT: Starting control 09/20/2013 18:25:09.000 HINT: File system successfully mounted 09/20/2013 18:25:09.000 HINT: Starting control 09/27/2013 07:50:57.000 HINT: File system successfully mounted 09/27/2013 07:50:57.000 HINT: Starting control 09/27/2013 07:52:06.000 HINT: File system successfully mounted 09/27/2013 07:52:06.000 HINT: Starting control 09/30/2013 09:36:13.000 HINT: File system successfully mounted 09/30/2013 09:36:13.000 HINT: Starting control 09/30/2013 09:44:09.000 HINT: File system successfully mounted 09/30/2013 09:44:09.000 HINT: Starting control 10/10/2013 04:35:20.000 HINT: File system successfully mounted 10/10/2013 04:35:20.000 HINT: Starting control 10/10/2013 07:30:00.000 HINT: File system successfully mounted 10/10/2013 07:30:00.000 HINT: Starting control 10/25/2013 07:09:23.000 HINT: File system successfully mounted 10/25/2013 07:09:23.000 HINT: Starting control 10/25/2013 07:16:53.000 HINT: File system successfully mounted 10/25/2013 07:16:53.000 HINT: Starting control 10/25/2013 07:41:52.000 HINT: File system successfully mounted 10/25/2013 07:41:52.000 HINT: Starting control 12/05/2013 11:00:55.000 HINT: File system successfully mounted 12/05/2013 11:00:55.000 HINT: Starting control 01/01/2014 07:57:35.000 HINT: File system successfully mounted 01/01/2014 07:57:35.000 HINT: Starting control 02/05/2014 02:35:58.000 HINT: File system successfully mounted 02/05/2014 02:35:58.000 HINT: Starting control 02/06/2014 01:41:59.000 HINT: File system successfully mounted 02/06/2014 01:41:59.000 HINT: Starting control 02/07/2014 07:32:52.000 HINT: File system successfully mounted 02/07/2014 07:32:52.000 HINT: Starting control 02/13/2014 20:52:45.000 HINT: File system successfully mounted 02/13/2014 20:52:45.000 HINT: Starting control 03/26/2014 10:46:59.000 HINT: File system successfully mounted 03/26/2014 10:46:59.000 HINT: Starting control 05/12/2014 09:33:53.000 HINT: File system successfully mounted 05/12/2014 09:33:53.000 HINT: Starting control 05/13/2014 12:35:08.000 HINT: File system successfully mounted 05/13/2014 12:35:08.000 HINT: Starting control 05/15/2014 03:19:47.000 HINT: File system successfully mounted 05/15/2014 03:19:47.000 HINT: Starting control 05/18/2014 08:46:05.000 HINT: File system successfully mounted 05/18/2014 08:46:05.000 HINT: Starting control 05/19/2014 03:54:17.000 HINT: File system successfully mounted 05/19/2014 03:54:17.000 HINT: Starting control 05/24/2014 07:09:20.000 HINT: File system successfully mounted 05/24/2014 07:09:20.000 HINT: Starting control 05/24/2014 07:25:29.000 HINT: File system successfully mounted 05/24/2014 07:25:29.000 HINT: Starting control 05/24/2014 07:36:10.000 HINT: File system successfully mounted 05/24/2014 07:36:10.000 HINT: Starting control 05/24/2014 07:58:53.000 HINT: File system successfully mounted 05/24/2014 07:58:53.000 HINT: Starting control 05/29/2014 04:50:49.000 HINT: File system successfully mounted 05/29/2014 04:50:49.000 HINT: Starting control 06/04/2014 11:48:37.000 HINT: File system successfully mounted 06/04/2014 11:48:37.000 HINT: Starting control 06/18/2014 05:03:08.000 HINT: File system successfully mounted 06/18/2014 05:03:08.000 HINT: Starting control 06/18/2014 05:56:47.000 HINT: File system successfully mounted 06/18/2014 05:56:47.000 HINT: Starting control 06/18/2014 06:03:48.000 HINT: File system successfully mounted 06/18/2014 06:03:48.000 HINT: Starting control 07/10/2014 21:30:34.000 HINT: File system successfully mounted 07/10/2014 21:30:34.000 HINT: Starting control 07/19/2014 19:12:11.000 HINT: File system successfully mounted 07/19/2014 19:12:11.000 HINT: Starting control 07/20/2014 08:17:37.000 HINT: File system successfully mounted 07/20/2014 08:17:37.000 HINT: Starting control 09/05/2014 09:17:12.000 HINT: File system successfully mounted 09/05/2014 09:17:12.000 HINT: Starting control 10/26/2014 20:05:42.000 HINT: File system successfully mounted 10/26/2014 20:05:42.000 HINT: Starting control 12/02/2014 14:03:52.000 HINT: File system successfully mounted 12/02/2014 14:03:52.000 HINT: Starting control 12/17/2014 15:13:46.000 HINT: File system successfully mounted 12/17/2014 15:13:46.000 HINT: Starting control 12/27/2014 19:43:23.000 HINT: File system successfully mounted 12/27/2014 19:43:23.000 HINT: Starting control 12/27/2014 20:29:49.000 HINT: File system successfully mounted 12/27/2014 20:29:49.000 HINT: Starting control 12/28/2014 03:14:15.000 HINT: File system successfully mounted 12/28/2014 03:14:15.000 HINT: Starting control 12/28/2014 03:55:02.000 HINT: File system successfully mounted 12/28/2014 03:55:02.000 HINT: Starting control 12/28/2014 04:22:21.000 HINT: File system successfully mounted 12/28/2014 04:22:21.000 HINT: Starting control 12/28/2014 06:00:29.000 HINT: File system successfully mounted 12/28/2014 06:00:29.000 HINT: Starting control 12/28/2014 06:22:52.000 HINT: File system successfully mounted 12/28/2014 06:22:52.000 HINT: Starting control 12/28/2014 08:02:17.000 HINT: File system successfully mounted 12/28/2014 08:02:17.000 HINT: Starting control 12/29/2014 11:59:19.000 HINT: File system successfully mounted 12/29/2014 11:59:19.000 HINT: Starting control 12/29/2014 12:51:49.000 HINT: File system successfully mounted 12/29/2014 12:51:49.000 HINT: Starting control 12/29/2014 13:13:59.000 HINT: File system successfully mounted 12/29/2014 13:13:59.000 HINT: Starting control 12/29/2014 14:36:09.000 HINT: File system successfully mounted 12/29/2014 14:36:09.000 HINT: Starting control 12/29/2014 14:58:18.000 HINT: File system successfully mounted 12/29/2014 14:58:18.000 HINT: Starting control 12/30/2014 04:39:14.000 HINT: File system successfully mounted 12/30/2014 04:39:14.000 HINT: Starting control 12/30/2014 04:47:10.000 HINT: File system successfully mounted 12/30/2014 04:47:10.000 HINT: Starting control 12/30/2014 07:24:55.000 HINT: File system successfully mounted 12/30/2014 07:24:55.000 HINT: Starting control 12/30/2014 08:13:27.000 HINT: File system successfully mounted 12/30/2014 08:13:27.000 HINT: Starting control 12/30/2014 08:17:18.000 HINT: File system successfully mounted 12/30/2014 08:17:18.000 HINT: Starting control 12/30/2014 08:33:14.000 HINT: File system successfully mounted 12/30/2014 08:33:14.000 HINT: Starting control 12/30/2014 08:46:07.000 HINT: File system successfully mounted 12/30/2014 08:46:07.000 HINT: Starting control 12/30/2014 09:19:27.000 HINT: File system successfully mounted 12/30/2014 09:19:27.000 HINT: Starting control 12/30/2014 09:52:59.000 HINT: File system successfully mounted 12/30/2014 09:52:59.000 HINT: Starting control 12/30/2014 10:10:44.000 HINT: File system successfully mounted 12/30/2014 10:10:44.000 HINT: Starting control 12/30/2014 10:21:44.000 HINT: File system successfully mounted 12/30/2014 10:21:44.000 HINT: Starting control 12/30/2014 10:37:13.000 HINT: File system successfully mounted 12/30/2014 10:37:13.000 HINT: Starting control 12/30/2014 10:51:50.000 HINT: File system successfully mounted 12/30/2014 10:51:50.000 HINT: Starting control 01/09/2015 13:55:48.000 HINT: File system successfully mounted 01/09/2015 13:55:48.000 HINT: Starting control 01/09/2015 16:02:29.000 HINT: File system successfully mounted 01/09/2015 16:02:29.000 HINT: Starting control 01/09/2015 23:47:29.000 HINT: File system successfully mounted 01/09/2015 23:47:29.000 HINT: Starting control 02/09/2015 17:05:01.000 HINT: File system successfully mounted 02/09/2015 17:05:01.000 HINT: Starting control 02/16/2015 06:19:48.000 HINT: File system successfully mounted 02/16/2015 06:19:48.000 HINT: Starting control 02/25/2015 13:48:22.000 HINT: File system successfully mounted 02/25/2015 13:48:22.000 HINT: Starting control 03/23/2015 20:24:36.000 HINT: File system successfully mounted 03/23/2015 20:24:36.000 HINT: Starting control 04/07/2015 11:36:23.000 HINT: File system successfully mounted 04/07/2015 11:36:23.000 HINT: Starting control 06/23/2015 09:14:19.000 HINT: File system successfully mounted 06/23/2015 09:14:19.000 HINT: Starting control 06/23/2015 20:02:53.000 HINT: File system successfully mounted 06/23/2015 20:02:53.000 HINT: Starting control 07/13/2015 10:03:34.000 HINT: File system successfully mounted 07/13/2015 10:03:34.000 HINT: Starting control 08/03/2015 04:42:33.000 HINT: File system successfully mounted 08/03/2015 04:42:33.000 HINT: Starting control 09/07/2015 11:31:15.000 HINT: File system successfully mounted 09/07/2015 11:31:15.000 HINT: Starting control 10/08/2015 10:32:01.000 HINT: File system successfully mounted 10/08/2015 10:32:01.000 HINT: Starting control 10/11/2015 05:09:04.000 HINT: File system successfully mounted 10/11/2015 05:09:04.000 HINT: Starting control 10/11/2015 05:15:03.000 HINT: File system successfully mounted 10/11/2015 05:15:03.000 HINT: Starting control 10/11/2015 06:09:08.000 HINT: File system successfully mounted 10/11/2015 06:09:08.000 HINT: Starting control 10/11/2015 13:22:01.000 HINT: File system successfully mounted 10/11/2015 13:22:01.000 HINT: Starting control 11/06/2015 04:56:30.000 HINT: File system successfully mounted 11/06/2015 04:56:30.000 HINT: Starting control 11/06/2015 20:35:44.000 HINT: File system successfully mounted 11/06/2015 20:35:44.000 HINT: Starting control 12/10/2015 05:58:33.000 HINT: File system successfully mounted 12/10/2015 05:58:33.000 HINT: Starting control 12/10/2015 06:31:00.000 HINT: File system successfully mounted 12/10/2015 06:31:00.000 HINT: Starting control 12/10/2015 06:35:38.000 HINT: File system successfully mounted 12/10/2015 06:35:38.000 HINT: Starting control 12/15/2015 00:39:39.000 HINT: File system successfully mounted 12/15/2015 00:39:39.000 HINT: Starting control 12/27/2015 08:49:49.000 HINT: File system successfully mounted 12/27/2015 08:49:49.000 HINT: Starting control 03/03/2003 03:03:03.000 HINT: File system successfully mounted 03/03/2003 03:03:03.000 HINT: Starting control 01/13/2016 04:10:49.000 HINT: File system successfully mounted 01/13/2016 04:10:49.000 HINT: Starting control 02/04/2016 13:15:52.000 HINT: File system successfully mounted 02/04/2016 13:15:52.000 HINT: Starting control 02/14/2016 10:09:05.000 HINT: File system successfully mounted 02/14/2016 10:09:05.000 HINT: Starting control 02/14/2016 10:38:15.000 HINT: File system successfully mounted 02/14/2016 10:38:15.000 HINT: Starting control 02/14/2016 10:44:05.000 HINT: File system successfully mounted 02/14/2016 10:44:05.000 HINT: Starting control 02/14/2016 11:19:06.000 HINT: File system successfully mounted 02/14/2016 11:19:06.000 HINT: Starting control 02/14/2016 11:23:12.000 HINT: File system successfully mounted 02/14/2016 11:23:12.000 HINT: Starting control 02/25/2016 08:53:39.000 HINT: File system successfully mounted 02/25/2016 08:53:39.000 HINT: Starting control 02/27/2016 11:37:08.000 HINT: File system successfully mounted 02/27/2016 11:37:08.000 HINT: Starting control 02/28/2016 04:01:23.000 HINT: File system successfully mounted 02/28/2016 04:01:23.000 HINT: Starting control 02/28/2016 06:01:11.000 HINT: File system successfully mounted 02/28/2016 06:01:11.000 HINT: Starting control 02/28/2016 11:08:19.000 HINT: File system successfully mounted 02/28/2016 11:08:19.000 HINT: Starting control 02/28/2016 12:49:47.000 HINT: File system successfully mounted 02/28/2016 12:49:47.000 HINT: Starting control 02/29/2016 05:55:19.000 HINT: File system successfully mounted 02/29/2016 05:55:19.000 HINT: Starting control 03/01/2016 05:41:23.000 HINT: File system successfully mounted 03/01/2016 05:41:23.000 HINT: Starting control 03/03/2016 12:25:51.000 HINT: File system successfully mounted 03/03/2016 12:25:51.000 HINT: Starting control 03/03/2016 12:32:17.000 HINT: File system successfully mounted 03/03/2016 12:32:17.000 HINT: Starting control 03/08/2016 03:10:40.000 HINT: File system successfully mounted 03/08/2016 03:10:40.000 HINT: Starting control 03/10/2016 13:47:32.000 HINT: File system successfully mounted 03/10/2016 13:47:32.000 HINT: Starting control 03/11/2016 00:03:44.000 HINT: File system successfully mounted 03/11/2016 00:03:44.000 HINT: Starting control 04/16/2016 12:11:11.000 HINT: File system successfully mounted 04/16/2016 12:11:11.000 HINT: Starting control 05/19/2016 03:26:52.000 HINT: File system successfully mounted 05/19/2016 03:26:52.000 HINT: Starting control 05/19/2016 04:20:46.000 HINT: File system successfully mounted 05/19/2016 04:20:46.000 HINT: Starting control 06/21/2016 06:17:32.000 HINT: File system successfully mounted 06/21/2016 06:17:32.000 HINT: Starting control 06/23/2016 22:18:47.000 HINT: File system successfully mounted 06/23/2016 22:18:47.000 HINT: Starting control 07/23/2016 02:48:50.000 HINT: File system successfully mounted 07/23/2016 02:48:50.000 HINT: Starting control 08/10/2016 05:56:06.000 HINT: File system successfully mounted 08/10/2016 05:56:06.000 HINT: Starting control 08/10/2016 20:19:00.000 HINT: File system successfully mounted 08/10/2016 20:19:00.000 HINT: Starting control 10/03/2016 22:03:05.000 HINT: File system successfully mounted 10/03/2016 22:03:05.000 HINT: Starting control 11/04/2016 06:39:56.000 HINT: File system successfully mounted 11/04/2016 06:39:56.000 HINT: Starting control 12/30/2016 04:08:30.000 HINT: File system successfully mounted 12/30/2016 04:08:30.000 HINT: Starting control 12/30/2016 05:22:57.000 HINT: File system successfully mounted 12/30/2016 05:22:57.000 HINT: Starting control 12/30/2016 08:04:22.000 HINT: File system successfully mounted 12/30/2016 08:04:22.000 HINT: Starting control 12/30/2016 08:22:39.000 HINT: File system successfully mounted 12/30/2016 08:22:39.000 HINT: Starting control 12/30/2016 12:13:02.000 HINT: File system successfully mounted 12/30/2016 12:13:02.000 HINT: Starting control 12/30/2016 13:00:33.000 HINT: File system successfully mounted 12/30/2016 13:00:33.000 HINT: Starting control 02/02/2017 10:35:34.000 HINT: File system successfully mounted 02/02/2017 10:35:34.000 HINT: Starting control 02/18/2017 14:58:16.000 HINT: File system successfully mounted 02/18/2017 14:58:16.000 HINT: Starting control 02/18/2017 15:43:16.000 HINT: File system successfully mounted 02/18/2017 15:43:16.000 HINT: Starting control 02/18/2017 15:49:47.000 HINT: File system successfully mounted 02/18/2017 15:49:47.000 HINT: Starting control 02/18/2017 16:01:09.000 HINT: File system successfully mounted 02/18/2017 16:01:09.000 HINT: Starting control 02/18/2017 22:40:40.000 HINT: File system successfully mounted 02/18/2017 22:40:40.000 HINT: Starting control 03/05/2017 10:49:50.000 HINT: File system successfully mounted 03/05/2017 10:49:50.000 HINT: Starting control 03/18/2017 08:15:10.000 HINT: File system successfully mounted 03/18/2017 08:15:10.000 HINT: Starting control 08/28/2017 03:59:46.000 HINT: File system successfully mounted 08/28/2017 03:59:46.000 HINT: Starting control 09/29/2017 10:58:08.000 HINT: File system successfully mounted 09/29/2017 10:58:08.000 HINT: Starting control 09/29/2017 11:22:28.000 HINT: File system successfully mounted 09/29/2017 11:22:28.000 HINT: Starting control 10/02/2017 04:28:51.000 HINT: File system successfully mounted 10/02/2017 04:28:51.000 HINT: Starting control 10/02/2017 04:50:33.000 HINT: File system successfully mounted 10/02/2017 04:50:33.000 HINT: Starting control 10/04/2017 04:26:54.000 HINT: File system successfully mounted 10/04/2017 04:26:54.000 HINT: Starting control 10/12/2017 11:20:16.000 HINT: File system successfully mounted 10/12/2017 11:20:16.000 HINT: Starting control 10/26/2017 07:18:24.000 HINT: File system successfully mounted 10/26/2017 07:18:24.000 HINT: Starting control 11/29/2017 04:46:34.000 HINT: File system successfully mounted 11/29/2017 04:46:34.000 HINT: Starting control 12/07/2017 09:12:22.000 HINT: File system successfully mounted 12/07/2017 09:12:22.000 HINT: Starting control 12/07/2017 09:32:42.000 HINT: File system successfully mounted 12/07/2017 09:32:42.000 HINT: Starting control 01/09/2018 02:54:31.000 HINT: File system successfully mounted 01/09/2018 02:54:31.000 HINT: Starting control 01/09/2018 09:50:33.000 HINT: File system successfully mounted 01/09/2018 09:50:33.000 HINT: Starting control 02/07/2018 03:09:14.000 HINT: File system successfully mounted 02/07/2018 03:09:14.000 HINT: Starting control 02/21/2018 11:11:02.000 HINT: File system successfully mounted 02/21/2018 11:11:02.000 HINT: Starting control 03/03/2018 10:16:46.000 HINT: File system successfully mounted 03/03/2018 10:16:46.000 HINT: Starting control 03/03/2018 10:20:57.000 HINT: File system successfully mounted 03/03/2018 10:20:57.000 HINT: Starting control 03/04/2018 14:10:59.000 HINT: File system successfully mounted 03/04/2018 14:10:59.000 HINT: Starting control 03/11/2018 19:42:44.000 HINT: File system successfully mounted 03/11/2018 19:42:44.000 HINT: Starting control 03/11/2018 20:14:42.000 HINT: File system successfully mounted 03/11/2018 20:14:42.000 HINT: Starting control 03/11/2018 20:43:27.000 HINT: File system successfully mounted 03/11/2018 20:43:27.000 HINT: Starting control 03/13/2018 04:15:30.000 HINT: File system successfully mounted 03/13/2018 04:15:30.000 HINT: Starting control 03/13/2018 04:50:53.000 HINT: File system successfully mounted 03/13/2018 04:50:53.000 HINT: Starting control 03/13/2018 07:47:42.000 HINT: File system successfully mounted 03/13/2018 07:47:42.000 HINT: Starting control 03/13/2018 10:27:52.000 HINT: File system successfully mounted 03/13/2018 10:27:52.000 HINT: Starting control 03/13/2018 11:23:11.000 HINT: File system successfully mounted 03/13/2018 11:23:11.000 HINT: Starting control 03/13/2018 11:51:15.000 HINT: File system successfully mounted 03/13/2018 11:51:15.000 HINT: Starting control 03/13/2018 12:24:39.000 HINT: File system successfully mounted 03/13/2018 12:24:39.000 HINT: Starting control 03/14/2018 04:07:44.000 HINT: File system successfully mounted 03/14/2018 04:07:44.000 HINT: Starting control 03/19/2018 12:23:55.000 HINT: File system successfully mounted 03/19/2018 12:23:55.000 HINT: Starting control 05/12/2018 17:43:09.000 HINT: File system successfully mounted 05/12/2018 17:43:09.000 HINT: Starting control 05/12/2018 18:10:09.000 HINT: File system successfully mounted 05/12/2018 18:10:09.000 HINT: Starting control 06/25/2018 03:28:46.000 HINT: File system successfully mounted 06/25/2018 03:28:46.000 HINT: Starting control 06/25/2018 12:19:32.000 HINT: File system successfully mounted 06/25/2018 12:19:32.000 HINT: Starting control 06/25/2018 17:07:10.000 HINT: File system successfully mounted 06/25/2018 17:07:10.000 HINT: Starting control 06/25/2018 17:11:14.000 HINT: File system successfully mounted 06/25/2018 17:11:14.000 HINT: Starting control 06/25/2018 17:12:42.000 HINT: File system successfully mounted 06/25/2018 17:12:42.000 HINT: Starting control 06/26/2018 03:11:58.000 HINT: File system successfully mounted 06/26/2018 03:11:58.000 HINT: Starting control 06/29/2018 02:18:42.000 HINT: File system successfully mounted 06/29/2018 02:18:42.000 HINT: Starting control 06/29/2018 03:18:53.000 HINT: File system successfully mounted 06/29/2018 03:18:53.000 HINT: Starting control 08/04/2018 09:06:40.000 HINT: File system successfully mounted 08/04/2018 09:06:40.000 HINT: Starting control 08/04/2018 09:17:25.000 HINT: File system successfully mounted 08/04/2018 09:17:25.000 HINT: Starting control 08/04/2018 09:32:03.000 HINT: File system successfully mounted 08/04/2018 09:32:03.000 HINT: Starting control 08/04/2018 09:49:20.000 HINT: File system successfully mounted 08/04/2018 09:49:20.000 HINT: Starting control 08/04/2018 09:49:49.000 HINT: File system successfully mounted 08/04/2018 09:49:49.000 HINT: Starting control 08/04/2018 09:55:26.000 HINT: File system successfully mounted 08/04/2018 09:55:26.000 HINT: Starting control 08/15/2018 11:57:52.000 HINT: File system successfully mounted 08/15/2018 11:57:52.000 HINT: Starting control 08/15/2018 12:57:08.000 HINT: File system successfully mounted 08/15/2018 12:57:08.000 HINT: Starting control 08/16/2018 04:27:12.000 HINT: File system successfully mounted 08/16/2018 04:27:12.000 HINT: Starting control 08/16/2018 04:32:54.000 HINT: File system successfully mounted 08/16/2018 04:32:54.000 HINT: Starting control 08/16/2018 04:39:18.000 HINT: File system successfully mounted 08/16/2018 04:39:18.000 HINT: Starting control 08/16/2018 04:50:11.000 HINT: File system successfully mounted 08/16/2018 04:50:11.000 HINT: Starting control 08/16/2018 05:13:56.000 HINT: File system successfully mounted 08/16/2018 05:13:56.000 HINT: Starting control 08/16/2018 06:13:27.000 HINT: File system successfully mounted 08/16/2018 06:13:27.000 HINT: Starting control 09/09/2018 11:21:25.000 HINT: File system successfully mounted 09/09/2018 11:21:25.000 HINT: Starting control 09/10/2018 09:21:10.000 HINT: File system successfully mounted 09/10/2018 09:21:10.000 HINT: Starting control 09/21/2018 01:19:03.000 HINT: File system successfully mounted 09/21/2018 01:19:03.000 HINT: Starting control 09/21/2018 08:36:38.000 HINT: File system successfully mounted 09/21/2018 08:36:38.000 HINT: Starting control 06/21/2019 20:45:05.000 HINT: File system successfully mounted 06/21/2019 20:45:05.000 HINT: Starting control 06/21/2019 21:06:07.000 HINT: File system successfully mounted 06/21/2019 21:06:07.000 HINT: Starting control 06/22/2019 12:21:50.000 HINT: File system successfully mounted 06/22/2019 12:21:50.000 HINT: Starting control 07/29/2019 00:04:20.000 HINT: File system successfully mounted 07/29/2019 00:04:20.000 HINT: Starting control 07/29/2019 00:07:38.000 HINT: File system successfully mounted 07/29/2019 00:07:38.000 HINT: Starting control 08/05/2019 18:56:13.000 HINT: File system successfully mounted 08/05/2019 18:56:13.000 HINT: Starting control 08/19/2019 09:55:38.000 HINT: File system successfully mounted 08/19/2019 09:55:38.000 HINT: Starting control 10/01/2019 03:07:50.000 HINT: File system successfully mounted 10/01/2019 03:07:50.000 HINT: Starting control 01/22/2020 09:57:36.000 HINT: File system successfully mounted 01/22/2020 09:57:36.000 HINT: Starting control 03/15/2020 12:07:41.000 HINT: File system successfully mounted 03/15/2020 12:07:41.000 HINT: Starting control 04/01/2020 08:35:02.000 HINT: File system successfully mounted 04/01/2020 08:35:02.000 HINT: Starting control 01/01/1992 00:00:00.000 HINT: File system successfully mounted 01/01/1992 00:00:00.000 HINT: Starting control 01/01/1992 00:00:00.000 WARN: NVRAM reinitialized due to service installation mode 01/01/1992 00:00:00.000 HINT: Creating NVRAM-parameter-group "ComConfig" 01/01/1992 00:00:00.000 HINT: NVRAM parameters (ComConfig): New version found. Old version = 0.0; new version = 1.2 01/01/1992 00:00:00.000 HINT: NVRAM-parameters reloaded from file (ComConfig) 01/01/1992 00:00:00.000 HINT: Creating NVRAM-parameter-group "DiagBuf" 01/01/1992 00:00:00.000 HINT: NVRAM parameters (DiagBuf): New version found. Old version = 0.0; new version = 2.0 01/01/1992 00:00:00.000 HINT: NVRAM-parameters reloaded from file (DiagBuf) 01/01/1992 00:00:00.000 HINT: Creating NVRAM-parameter-group "SystemDataR" 01/01/1992 00:00:00.000 HINT: NVRAM parameters (SystemDataR): New version found. Old version = 0.0; new version = 1.3 01/01/1992 00:00:00.000 HINT: Creating NVRAM-parameter-group "TaskData" 01/01/1992 00:00:00.000 HINT: NVRAM parameters (TaskData): New version found. Old version = 0.0; new version = 1.0 01/01/1992 00:00:00.000 HINT: Creating NVRAM-parameter-group "SystemDataNR" 01/01/1992 00:00:00.000 HINT: NVRAM parameters (SystemDataNR): New version found. Old version = 0.0; new version = 1.0 01/01/1992 00:00:00.000 HINT: NVRAM-parameters reloaded from file (SystemDataNR) 01/01/1992 00:00:00.000 HINT: Creating NVRAM-parameter-group "ComTrace" 01/01/1992 00:00:00.000 HINT: NVRAM parameters (ComTrace): New version found. Old version = 0.0; new version = 1.0 01/01/1992 00:00:00.000 HINT: NVRAM-parameters reloaded from file (ComTrace) 01/01/1992 00:00:00.000 HINT: Creating NVRAM-parameter-group "ExtDiagBuf" 01/01/1992 00:00:00.000 HINT: NVRAM parameters (ExtDiagBuf): New version found. Old version = 0.0; new version = 2.0 01/01/1992 00:00:00.000 HINT: NVRAM-parameters reloaded from file (ExtDiagBuf) 01/01/1992 00:00:00.000 HINT: File system successfully mounted 01/01/1992 00:00:00.000 HINT: Restarting control 01/01/1992 00:07:00.000 HINT: File system successfully mounted 01/01/1992 00:07:00.000 HINT: Starting control 01/01/1992 00:15:29.000 HINT: File system successfully mounted 01/01/1992 00:15:29.000 HINT: Starting control 01/01/1992 00:30:07.000 HINT: File system successfully mounted 01/01/1992 00:30:07.000 HINT: Starting control 01/01/1992 00:57:06.000 HINT: File system successfully mounted 01/01/1992 00:57:06.000 HINT: Starting control 01/01/1992 01:03:39.000 HINT: File system successfully mounted 01/01/1992 01:03:39.000 HINT: Starting control 01/01/1992 01:16:54.000 HINT: File system successfully mounted 01/01/1992 01:16:54.000 HINT: Starting control 01/01/1992 01:20:54.000 HINT: File system successfully mounted 01/01/1992 01:20:54.000 HINT: Starting control 01/01/1992 01:23:49.000 HINT: File system successfully mounted 01/01/1992 01:23:49.000 HINT: Starting control 01/01/1992 01:26:30.000 HINT: File system successfully mounted 01/01/1992 01:26:30.000 HINT: Starting control 04/11/2020 07:23:53.000 HINT: File system successfully mounted 04/11/2020 07:23:53.000 HINT: Starting control 04/11/2020 07:28:32.000 HINT: File system successfully mounted 04/11/2020 07:28:32.000 HINT: Starting control 04/11/2020 07:28:32.000 ERROR: Control has been switched off during file write operation! 04/11/2020 07:34:32.000 HINT: File system successfully mounted 04/11/2020 07:34:32.000 HINT: Starting control 04/11/2020 07:38:58.000 HINT: File system successfully mounted 04/11/2020 07:38:58.000 HINT: Starting control 04/11/2020 07:46:33.000 HINT: File system successfully mounted 04/11/2020 07:46:33.000 HINT: Starting control 04/11/2020 07:51:04.000 HINT: File system successfully mounted 04/11/2020 07:51:04.000 HINT: Starting control 04/11/2020 08:04:38.000 HINT: File system successfully mounted 04/11/2020 08:04:38.000 HINT: Starting control 04/13/2020 04:29:30.000 HINT: File system successfully mounted 04/13/2020 04:29:30.000 HINT: Starting control 04/13/2020 05:50:02.000 HINT: File system successfully mounted 04/13/2020 05:50:02.000 HINT: Starting control 04/13/2020 05:54:55.000 HINT: File system successfully mounted 04/13/2020 05:54:55.000 HINT: Starting control 04/13/2020 06:00:30.000 HINT: File system successfully mounted 04/13/2020 06:00:30.000 HINT: Starting control 04/13/2020 06:03:59.000 HINT: File system successfully mounted 04/13/2020 06:03:59.000 HINT: Starting control 04/13/2020 06:11:23.000 HINT: File system successfully mounted 04/13/2020 06:11:23.000 HINT: Starting control 04/13/2020 06:17:49.000 HINT: File system successfully mounted 04/13/2020 06:17:49.000 HINT: Starting control 04/13/2020 06:21:26.000 HINT: File system successfully mounted 04/13/2020 06:21:26.000 HINT: Starting control 04/13/2020 06:33:26.000 HINT: File system successfully mounted 04/13/2020 06:33:26.000 HINT: Starting control 01/01/1992 00:00:00.000 HINT: File system successfully mounted 01/01/1992 00:00:00.000 HINT: Starting control 01/01/1992 00:00:00.000 WARN: NVRAM reinitialized due to service installation mode 01/01/1992 00:00:00.000 HINT: Creating NVRAM-parameter-group "ComConfig" 01/01/1992 00:00:00.000 HINT: NVRAM parameters (ComConfig): New version found. Old version = 0.0; new version = 1.2 01/01/1992 00:00:00.000 HINT: NVRAM-parameters reloaded from file (ComConfig) 01/01/1992 00:00:00.000 HINT: Creating NVRAM-parameter-group "DiagBuf" 01/01/1992 00:00:00.000 HINT: NVRAM parameters (DiagBuf): New version found. Old version = 0.0; new version = 2.0 01/01/1992 00:00:00.000 HINT: NVRAM-parameters reloaded from file (DiagBuf) 01/01/1992 00:00:00.000 HINT: Creating NVRAM-parameter-group "SystemDataR" 01/01/1992 00:00:00.000 HINT: NVRAM parameters (SystemDataR): New version found. Old version = 0.0; new version = 1.3 01/01/1992 00:00:00.000 HINT: Creating NVRAM-parameter-group "TaskData" 01/01/1992 00:00:00.000 HINT: NVRAM parameters (TaskData): New version found. Old version = 0.0; new version = 1.0 01/01/1992 00:00:00.000 HINT: Creating NVRAM-parameter-group "SystemDataNR" 01/01/1992 00:00:00.000 HINT: NVRAM parameters (SystemDataNR): New version found. Old version = 0.0; new version = 1.0 01/01/1992 00:00:00.000 HINT: NVRAM-parameters reloaded from file (SystemDataNR) 01/01/1992 00:00:00.000 HINT: Creating NVRAM-parameter-group "ComTrace" 01/01/1992 00:00:00.000 HINT: NVRAM parameters (ComTrace): New version found. Old version = 0.0; new version = 1.0 01/01/1992 00:00:00.000 HINT: NVRAM-parameters reloaded from file (ComTrace) 01/01/1992 00:00:00.000 HINT: Creating NVRAM-parameter-group "ExtDiagBuf" 01/01/1992 00:00:00.000 HINT: NVRAM parameters (ExtDiagBuf): New version found. Old version = 0.0; new version = 2.0 01/01/1992 00:00:00.000 HINT: NVRAM-parameters reloaded from file (ExtDiagBuf) 01/01/1992 00:00:00.000 HINT: File system successfully mounted 01/01/1992 00:00:00.000 HINT: Restarting control 01/01/1992 00:10:14.000 HINT: File system successfully mounted 01/01/1992 00:10:14.000 HINT: Starting control 01/01/1992 00:22:31.000 HINT: File system successfully mounted 01/01/1992 00:22:31.000 HINT: Starting control 01/01/1992 00:44:32.000 HINT: File system successfully mounted 01/01/1992 00:44:32.000 HINT: Starting control 01/03/1992 21:57:54.000 HINT: File system successfully mounted 01/03/1992 21:57:54.000 HINT: Starting control -------------------------------------------------------------------------------- -------------------------------------------------------------------------------- -------------------------------------------------------------------------------- - content.txt - -------------------------------------------------------------------------------- Compact Flash SIMOTION D4X5_V26_PN22 V04.01.04.01 (internal Version 47.76.10.00) includes: ---------------------------------------------------------------------------------------------- Komponente interne Version Stempel - SD_FW_Tools 02.60.42.00 SINAMICS_SD_FW_TOOLS_02.60.42.00 - Lib_Target_ALL 02.60.42.00 SINAMICS_LIB_TARGET_ALL_02.60.42.00 - Lvar_Target_ALL 02.60.42.00 SINAMICS_LVAR_TARGET_ALL_02.60.42.00 - SD_DIRECTORY 02.60.42.00 SINAMICS_INFO_02.60.42.00 - SIMOTION_D4x5_FW 47.76.10.00 UMCPAT_47.76.10 - BIOS_710_802D 02.02.00.00 BIOS_710_V02.02.00.00 - CBE30_PN22_FW 04.01.55.07 CBE_M0200_5507 - DAC_ABO2_Target 02.60.44.00 SINAMICS_DAC_ABO2_TARGET_02.60.44.00 - DAC_ABO_Target 02.60.44.00 SINAMICS_DAC_ABO_TARGET_02.60.44.00 - DAC_CUA31X_Target 02.60.44.00 SINAMICS_DAC_CUA31X_TARGET_02.60.44.00 - DAC_CUA31_Target 02.50.32.13 SINAMICS_DAC_CUA31_TARGET_02.50.32.13 - DAC_CUA32_Target 02.60.44.00 SINAMICS_DAC_CUA32_TARGET_02.60.44.00 - DAC_DMC20_Target 02.60.42.00 SINAMICS_DAC_DMC20_TARGET_02.60.42.00 - DAC_PSAD_Target 02.60.44.00 SINAMICS_DAC_PSAD_TARGET_02.60.44.00 - DAC_SMC30D_Target 02.60.44.00 SINAMICS_DAC_SMC30D_TARGET_02.60.44.00 - DAC_TM31D_Target 02.60.44.00 SINAMICS_DAC_TM31D_TARGET_02.60.44.00 - DAC_TM41D_Target 02.60.44.00 SINAMICS_DAC_TM41D_TARGET_02.60.44.00 - DAC_TM54F_Target 02.60.44.00 SINAMICS_DAC_TM54F_TARGET_02.60.44.00 - DSAC_DME20_Target 02.60.42.00 SINAMICS_DSAC_DME20_TARGET_02.60.42.00 - DSAC_SMI20D_Target 02.60.44.00 SINAMICS_DSAC_SMI20D_TARGET_02.60.44.00 - SAC_ABO3D_FW 02.60.42.00 SINAMICS_SAC_ABO3D_FW_02.60.42.00 - SAC_ABO3X_FW 02.60.42.00 SINAMICS_SAC_ABO3X_FW_02.60.42.00 - SAC_ABO_Bootmaster 02.50.20.00 SINAMICS_SAC_ABO_BOOTMASTER_02.50.20.00 - SAC_PSAF_FW 02.60.42.00 SINAMICS_SAC_PSAF_FW_02.60.42.00 - SAC_PSAI_FW 02.60.42.00 SINAMICS_SAC_PSAI_FW_02.60.42.00 - SAC_PSA_FW 02.10.42.00 SINAMICS_SAC_PSA_FW_02.10.42.00 - SAC_SMC10B_Bootmaster 02.20.02.00 SINAMICS_SAC_SMC10B_BOOTMASTER_02.20.02.00 - SAC_SMC10X_FW 02.60.42.00 SINAMICS_SAC_SMC10X_FW_02.60.42.00 - SAC_SMC20B_Bootmaster 02.20.02.00 SINAMICS_SAC_SMC20B_BOOTMASTER_02.20.02.00 - SAC_SMC20X_FW 02.60.42.00 SINAMICS_SAC_SMC20X_FW_02.60.42.00 - SAC_SMC30B_Bootmaster 02.40.16.00 SINAMICS_SAC_SMC30B_BOOTMASTER_02.40.16.00 - SAC_SMC30X_FW 02.60.42.00 SINAMICS_SAC_SMC30X_FW_02.60.42.00 - SAC_SMC30_FW 02.40.35.05 SINAMICS_SAC_SMC30_FW_02.40.35.05 - SAC_SMI10B_Bootmaster 02.20.02.00 SINAMICS_SAC_SMI10B_BOOTMASTER_02.20.02.00 - SAC_SMI10X_FW 02.60.42.00 SINAMICS_SAC_SMI10X_FW_02.60.42.00 - SAC_SMI20B_Bootmaster 02.20.02.00 SINAMICS_SAC_SMI20B_BOOTMASTER_02.20.02.00 - SAC_SMI20X_FW 02.60.42.00 SINAMICS_SAC_SMI20X_FW_02.60.42.00 - SAC_TM15_FW 02.60.42.00 SINAMICS_SAC_TM15_FW_02.60.42.00 - SAC_TM17_FW 02.60.42.00 SINAMICS_SAC_TM17_FW_02.60.42.00 - SAC_TM31_FW 02.60.42.00 SINAMICS_SAC_TM31_FW_02.60.42.00 - SAC_TM41_FW 02.60.42.00 SINAMICS_SAC_TM41_FW_02.60.42.00 - SAC_VSM_FW 02.50.32.29 SINAMICS_SAC_VSM_FW_02.50.32.29 - SD_AppView_000 02.60.42.00 SINAMICS_PD000_02.60.42.00 - SD_BICO 02.60.42.00 SINAMICS_SD_BICO_02.60.42.00 - SD_CX32_Target_S120 02.60.42.00 SINAMICS_SD_CX32_TARGET_S120_02.60.42.00 - SD_ENCDB 02.60.42.00 SINAMICS_SD_ENCDB_02.60.42.00 - SD_MD5FILE 02.60.42.00 SINAMICS_SD_MD5FILE_02.60.42.00 - SD_MOTDB 02.60.42.00 SINAMICS_SD_MOTDB_02.60.42.00 - SD_MTXDEU_lang 02.60.42.00 SINAMICS_SD_MTXDEU_LANG_02.60.42.00 - SD_MTXENG_lang 02.60.42.00 SINAMICS_SD_MTXENG_LANG_02.60.42.00 - SD_MTXFRA_lang 02.60.42.00 SINAMICS_SD_MTXFRA_LANG_02.60.42.00 - SD_MTXITA_lang 02.60.42.00 SINAMICS_SD_MTXITA_LANG_02.60.42.00 - SD_MTXTXTDESC 02.60.42.00 SINAMICS_SD_MTXTXTDESC_02.60.42.00 - SD_RTM 02.60.42.00 SINAMICS_SD_RTM_02.60.42.00 - SD_SYSDESC 02.60.42.00 SINAMICS_SD_SYSDESC_02.60.42.00 - SD_TXTDESC 02.60.42.00 SINAMICS_SD_TXTDESC_02.60.42.00 - SD_UNITDESC 02.60.42.00 SINAMICS_SD_UNITDESC_02.60.42.00 -------------------------------------------------------------------------------- -------------------------------------------------------------------------------- -------------------------------------------------------------------------------- - Alarms - -------------------------------------------------------------------------------- Information: (PG) 17.04.20 11:59:00:000 D445 OK