介绍计数器DB数据块

DB Assignment

地址名称数据类型初始值含义
计数模式
测量模式
0.0
AR1_BUFFER
DWORD
DW#16#0
AR1 buffer
AR1 buffer
4.0
FP
BYTE
B#16#0
Flag byte
Flag byte
6.0
MOD_ADR
WORD
W#16#0
Module address
Module address
8.0
CH_ADR
DWORD
DW#16#0
Channel address
Channel address
12.0
U_D_LGTH
BYTE
B#16#0
User data length
User data length
14.0
LOAD_VAL
DINT
L#0
New load value (write user)
Lower limit (write user)
18.0
CMP_V1
DINT
L#0
New comparison value 1 (write user)
Upper limit (write user)
22.0
CMP_V2
DINT
L#0
New comparison value 2 (write user)
Update time(write user)
27.0
ENSET_UP
BOOL
FALSE
Enable setting in up
direction (write user)

27.1
ENSET_DN
BOOL
FALSE
Enable setting in down
direction (write user)

28.0
CTRL_DO0
BOOL
FALSE
Monitor digital output
DO0 (write user)
28.1
CTRL_DO1
BOOL
FALSE
Monitor digital output
DO1 (write user)
30.0
LATCH_LOAD
DINT
L#0
Current load or latch
value (read user)
Current measured
value (read user)
34.0
ACT_CNTV
DINT
L#0
Current count value (read user)
Current count value (read user)
38.0
DA_ERR_W
WORD
W#16#0
Data error word (read user)
Data error word (read user)
40.0
OT_ERR_B
BYTE
B#16#0
Operation error byte (read user)
Operation error byte (read user)
41.4
DATA_ERR
BOOL
FALSE
Data error bit (read user)
Data error bit (read user)
41.7
PARA
BOOL
FALSE
Module parameterized (read user)
Module parameterized (read user)
42.0
E_BYTE_0
BYTE
B#16#0
Reserved
Reserved
43.0
STS_RUN
BOOL
FALSE
Status counter working
Status counter working
43.1
STS_DIR
BOOL
FALSE
Status count direction (read user)
Status count direction (read user)
43.2
STS_ZERO
BOOL
FALSE
Status zero pass (read user)
Full scale (read user)
43.3
STS_OFLW
BOOL
FALSE
Status overflow (read user)
Status overflow (read user)
43.4
STS_UFLW
BOOL
FALSE
Status underflow (read user)
Status underflow (read user)
43.5
STS_SYNC
BOOL
FALSE
Status counter synchronized (read user)

43.6
STS_GATE
BOOL
FALSE
Status internal gate (read user)
Status internal gate (read user)
43.7
STS_SW_G
BOOL
FALSE
Status software gate (read user)
Status software gate (read user)
44.0
STS_SET
BOOL
FALSE
Status digital input SET (read user)
Status digital input SET (read user)
44.1
STS_LATCH
BOOL
FALSE
New latch value (only in clock synchronous mode)

44.2
STS_STA
BOOL
FALSE
Status digital input START (read user)
Status digital input START (read user)
44.3
STS_STP
BOOL
FALSE
Status digital input STOP (read user)
Status digital input STOP (read user)
44.4
STS_CMP1
BOOL
FALSE
Status output comparison value 1 (read user)
Status output comparison value 1 (read user)
44.5
STS_CMP2
BOOL
FALSE
Status output comparison value 2 (read user)
Status output comparison value 2 (read user)
44.6
STS_COMP1
BOOL
FALSE
Stored status of comparator 1

44.7
STS_COMP1
BOOL
FALSE
Stored status of comparator 1

The following diagnostics data are entered by the FC DIAG_INF
54.0
MDL_DEFECT
BOOL
FALSE
Module error
Module error
54.1
INT_FAULT
BOOL
FALSE
Internal fault
Internal fault
54.2
EXT_FAULT
BOOL
FALSE
External fault
External fault
54.3
PNT_INFO
BOOL
FALSE
Channel fault (decoded from DW 58 onward)
Channel fault (decoded from DW 58 onward)
54.4
EXT_VOLTAGE
BOOL
FALSE
Auxiliary voltage fault
Auxiliary voltage fault
54.5
FLD_CNNCTR
BOOL
FALSE
Front connector
Front connector
54.6
NO_CONFIG
BOOL
FALSE
No parameterization
No parameterization
54.7
CONFIG_ERR
BOOL
FALSE
Parameterization faulty
Parameterization faulty
55.0
MDL_TYPE
BYTE
B#16#0
Module type
Module type
56.0
SUB_MDL_ERR
BOOL
FALSE
Interface module wrong or missing
Interface module wrong or missing
56.1
COMM_FAULT
BOOL
FALSE
Communication error
Communication error
56.2
MDL_STOP
BOOL
FALSE
RUN/STOP LED display
RUN/STOP LED display
56.3
WTCH_DOG_F AULT
BOOL
FALSE
Watchdog (FM)
Watchdog (FM)
56.4
INT_PS_FLT
BOOL
FALSE
Internal power supply fault
Internal power supply fault
56.5
PRIM_BATT_FL T
BOOL
FALSE
Battery monitoring
Battery monitoring
56.6
BCKUP_BATT_ FLT
BOOL
FALSE
Defective backup
Defective backup
57.0
RACK_FLT
BOOL
FALSE
Rack fault
Rack fault
57.1
PROC_FLT
BOOL
FALSE
CPU fault
CPU fault
57.2
EPROM_FLT
BOOL
FALSE
EPROM fault
EPROM fault
57.3
RAM_FLT
BOOL
FALSE
RAM fault
RAM fault
57.4
ADU_FLT
BOOL
FALSE
ADC fault
ADC fault
57.5
FUSE_FLT
BOOL
FALSE
Fuse
Fuse
57.6
HW_INTR_FLT
BOOL
FALSE
Process interrupt lost
Process interrupt lost
58.0
CH_TYPE
BYTE
B#16#0
Channel type
Channel type
59.0
LGTH_DIA
BYTE
B#16#0
Diagnostics data length per channel
Diagnostics data length per channel
60.0
CH_NO
BYTE
B#16#0
Channel number
Channel number
61.0
GRP_ERR1
BOOL
FALSE
Group error channel 1
Group error channel 1
61.1
GRP_ERR2
BOOL
FALSE
Not assigned on the FM 350-1
Not assigned on the FM 350-1
61.2
D_BIT7_2
BOOL
FALSE
DS1 byte 7 bit 2
DS1 byte 7 bit 2
61.3
D_BIT7_3
BOOL
FALSE
DS1 byte 7 bit 3
DS1 byte 7 bit 3
61.4
D_BIT7_4
BOOL
FALSE
DS1 byte 7 bit 4
DS1 byte 7 bit 4
61.5
D_BIT7_5
BOOL
FALSE
DS1 byte 7 bit 5
DS1 byte 7 bit 5
61.6
D_BIT7_6
BOOL
FALSE
DS1 byte 7 bit 6
DS1 byte 7 bit 6
61.7
D_BIT7_7
BOOL
FALSE
DS1 byte 7 bit 7
DS1 byte 7 bit 7
62.0
CH1_SIGA
BOOL
FALSE
Channel 1, error signal A
Channel 1, error signal A
62.1
CH1_SIGB
BOOL
FALSE
Channel 1, error signal B
Channel 1, error signal B
62.2
CH1_SIGZ
BOOL
FALSE
Channel 1, error signal zero
Channel 1, error signal zero
62.3
CH1_BETW
BOOL
FALSE
Channel 1, error between channels
Channel 1, error between channels
62.4
CH1_5V2
BOOL
FALSE
Channel 1, error in 5.2 V encoder supply
Channel 1, error in 5.2 V encoder supply
62.5
D_BIT8_5
BOOL
FALSE
DS1 byte 8 bit 5
DS1 byte 8 bit 5
62.6
D_BIT8_6
BOOL
FALSE
DS1 byte 8 bit 6
DS1 byte 8 bit 6
62.7
D_BIT8_7
BOOL
FALSE
DS1 byte 8 bit 7
DS1 byte 8 bit 7
63.0
D_BYTE9
BYTE
B#16#0
DS1 byte 9
DS1 byte 9
65.0
D_BYTE11
BYTE
B#16#0
DS1 byte 11
DS1 byte 11
66.0
D_BYTE12
BYTE
B#16#0
DS1 byte 12
DS1 byte 12
67.0
D_BYTE13
BYTE
B#16#0
DS1 byte 13
DS1 byte 13
68.0
D_BYTE14
BYTE
B#16#0
DS1 byte 14
DS1 byte 14
69.0
D_BYTE15
BYTE
B#16#0
DS1 byte 15
DS1 byte 15