1.这样可以,但是对系统有要求,个人建议还是安装博图V14自带的TIA Portal V14(WinCC Advanced)版本,这样兼容性好点。我把博图V14对系统的要求发上来你看一下
参考:《WINCC7.0 和博途WinCC V14 SP1 Professional区别在哪里》
http://www.ad.siemens.com.cn/service/answer/solution.aspx?Q_ID=178410&cid=1032
Delivery Release for WinCC V14 SP1
System requirements of engineering systems
All WinCC V14 SP1 Engineering- Editions are released for use with the following operating systems (64-bit only):
Windows 7 (64 Bit)
Windows 7 Home Premium SP1 (WinCC Basic only)
Windows 7 Professional SP1
Windows 7 Enterprise SP1
Windows 7 Ultimate SP1
Windows 8.1 (64 Bit)
Windows 8.1 (nur WinCC Basic)
Windows 8.1 Professional
Windows 8.1 Enterprise
Windows 10 (64 Bit, new with V14 SP1)
Windows 10 Home Version 1607 (WinCC Basic only)
Windows 10 Professional Version 1607
Windows 10 Enterprise Version 1607
Windows 10 Enterprise 2016 LTSB
Windows 10 Enterprise 2015 LTSB
Windows Server (64 Bit)
Windows Server 2008 R2 StdE SP1 (not for WinCC Basic)
Windows Server 2012 R2 StdE
Windows Server 2016 Standard
2.可以安装在同一台电脑上
3.电脑配置要求
The following table shows the recommended hardware for operating WinCC.
Hardware Recommendation
Computer SIMATIC Field PG M5 Advanced or higher (or comparable PC)
Processor Intel? Core? i5-6440EQ (2.7 GHz)
RAM 16 GB or more (for large projects 32 GB)
Hard disk SSD with at least 50 GB free storage capacity
Network 1 Gigabit (for multi-user)
Monitor 15.6" full HD display (1920 x 1080 or larger)
Portal WinCC Professional与WinCC V6/V7不能同时安装在同一台计算机上,无论是V13还是V14。只有Professional以下版本(Basic,Comfort,Advanced)的Portal WinCC才可以与WinCC同时安装在同一台计算机上。
Delivery release SIMATIC WinCC V14
https://support.industry.siemens.com/cs/cn/en/view/109739719