SIMATIC WinCC
linglong2020
wincc V7.4 SP1.Window10系统下运行VBS调试时:Visual studio 2010 shell 提示Invalid license data,Reinstall is required.
问题补充:
新装的系统,仅安装WINCCV7.4。换了台同事的电脑VBS调试勾选后也是如此。
小程序:
钻石用户推荐最佳答案
回答者:
nnnn1234
回答时间:2018-07-26 11:15
提问者对于答案的评价:
需要重新安装许可证
本回答有7位钻石用户推荐
This worked for me on Vista. It''s based on work-around at MS: http://connect.microsoft.com/VisualStudio/feedback/details/520110/invalid-license-data-reinstall-is-required
Download subinacl command line tool
http://www.microsoft.com/downloads/en/confirmation.aspx?FamilyID=e8ba3e56-d8fe-4a91-93cf-ed6985e3927b&displaylang=en
Run these commands:
subinacl /subkeyreg HKEY_CLASSES_ROOT\Licenses /setowner=everyone
subinacl /subkeyreg HKEY_CLASSES_ROOT\Licenses /grant=everyone=f
Start VS 2010 Express again and this time it asks for a license key.
(On Windows 7 Home I had to run the above commands twice before they worked correctly)