S7-1200 控制器 (CE-X21) 可通过 GPRS 进行无线通信
- 0
- 519
- 6576
An automation infrastructure contains RTUs with S7-1200 which shall communicate cost-effectively with a central station via the mobile communications network or via Ethernet.
This application examples constists of two application scenarios:
- Secure connection of an RTU with CP 1243-7 LTE to TeleControl ServerBasic
- Data Communication of S7-1200 Stations with TeleControl Server Basic V3.1
The documenation and the associated project are provided for each application scenario.
- Secure connection of an RTU with CP 1243-7 LTE to TeleControl ServerBasic
The infrastructure of a water treatment plant contains an RTU (Remote Terminal Unit) with S7-1200 and CP 1243-7 LTE to securely transmit encrypted process data over the mobile radio network to the control station.The RTU establishes an OpenVPN connection to SINEMA Remote Connect Server. The RTU communicates with TeleControl Server Basic via this OpenVPN connection and transmits process data over the TeleControl Basic protocol.
Fig. 01
Downloads
- Data Communication of S7-1200 Stations with TeleControl Server Basic V3.1
The infrastructure of a discharge treatment plant comprises two S7-1200 substations. The TeleControl Server Basic V3.1 in the central station enables a direct connection to both stations. Station 1 is connected to the TeleControl Server Basic V3.1 by means of the CP 1242-7 V2 GPRS via the mobile communications network. Station 2 is directly connected to the TeleControl Server Basic V3.1 by means of the CP 1243-1 via cable-based Ethernet. WinCC Advanced, WinCC Professional and WinCC V7 can be used as OPC UA client for visualization and control of process data.
Fig. 02
Advantages
- TeleControl Server Basic V3.1 enables economic data communication between substations and the central station.
- The data of the connected stations are available for any OPC UA client via the OPC UA interface of the TCSB.
- LTE, GPRS and internet: Always-on functionality.
- In case of a connection failure, the CPs buffer the data and transmit the bundled data to the TeleControl Server upon reconnection.
- If there is a brief interruption on the connection between the OPC UA client and the TCSB OPC UA server, the data remains available in the data buffer. Once the connection has been re-established, all values that have not been transferred will be sent to the OPC UA client.
Downloads
Documentation and example project with WinCC Advanced
Documentation and example project with WinCC Professional
Documentation and example project with WinCC V7
Last version
Project TIA Portal V14 (1,2 MB)
Further Information
Inter-Station Communication between S7-1200 Stations Using TCSB V3.1 via CP 1242-7 V2
Signaling and Switching via SMS with S7-1200 and CP 1242-7 GPRS V2
TeleService of a S7-1200 station via mobile network
Last modification
New application scenario "Secure connection of an RTU with CP 1243-7 LTE to TeleControl ServerBasic"
https://support.industry.siemens.com/cs/cn/zh/view/39863979
剩余80%未阅读,请登录后下载/查看文档
- 评论
-
分享
扫码分享
- 收藏 收藏
- 点赞 点赞
- 纠错 纠错
- 采用 S7-1200 和 CP 1242-7 通过 GPRS 进行无线数据通信,情景 4 - 远程服务
- 通过 SMS 与 S7-1200 控制器进行无线信号通信与交换通信
- 利用 S7-300/400/ET200S 控制器和 MD720-3 GPRS/GSM 调制解调器,通过短消息系统,实现无线信号传输和开关
- 通过 GPRS 和 S7-1200 以及 SIMATIC CP 1242-7 GPRS Scenario 3 实现无线数据通信 - 短信息通信
- 采用 S7-1200 和 CP 1242-7 通过 GPRS 实现无线数据通信 - 情景 2:交叉通信
- S7-1200 GPRS通讯快速入门
- S7-1200 GPRS通讯快速入门
- TIA Portal V12 库,含有用于通过 SIMATIC S7-1200/300/400 控制器对 SINAMICS G120 变频器进行控制的画面
- 在以太网、可靠的因特网和 (E)GPRS 环境 (Configuration 8) 中的 SINAUT ST7 远程控制组态示例
- 如何从CP 1242-7 GPRS V2中读取高级诊断数据?
{{item.nickName}}